Skip to content

Comparison of Static Air Support Devices (Repose®) and Alternating-Pressure Devices in the Prevention of Pressure Ulcers

Pressure Ulcer Prevention Using Static Air Support Devices (Repose®) Versus Alternating-Pressure Devices in a High Risk Population in Nursing Homes: A Multi-Center Prospective Randomized Controlled Trial and Qualitative Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03597750
Enrollment
308
Registered
2018-07-24
Start date
2017-04-19
Completion date
2018-07-15
Last updated
2018-10-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bed Sore, Pressure Injury, Pressure Sore, Pressure Ulcer

Keywords

Static air support devices, Alternating-pressure devices, High risk population, Elderly, Prevention

Brief summary

Maintaining and improving skin health are major goals in acute and long-term care. Patients at the extremes of age, the critically ill, medically compromised and those with immobility are at risk for developing several skin disorders, with pressure ulcers (PUs) as one of the most common and mostly preventable ones. Prevalence figures of PUs vary between 6.4% and 31.4%. PUs are described as localised injuries to the skin and/or underlying tissue, usually over a bony prominence, as a result of pressure or pressure combined with shear. Prevention of PUs is internationally seen to be a key quality indicator of care. To prevent PUs, reducing both the amount and the duration of pressure and shear at the pressure points of the body is strongly recommended. One of the interventions to achieving this, is the use of pressure-reducing devices (mattresses, cushions, etc.). Studies that compare the (cost-) effectiveness of different pressure-reducing devices are needed. The primary aim of this study is to compare the (cost-) effectiveness of pressure ulcer prevention in high risk patients using static air support devices (Repose®) versus alternating-pressure devices. The second aim is to get insight in patients' experiences and perceptions of comfort using static air support devices and alternating-pressure devices. The third aim is to get insight in caretakers' perceptions of barriers and facilitators of the use of static air support devices and alternating-pressure devices and to reveal how these perceptions influence the readiness to use the products in clinical practice. This randomized controlled trial will be performed in ca. 25 nursing homes in a random sample of 306 residents who are at high risk of developing pressure ulcers. Residents will be included in the study for a period of 14 days. Skin assessment and risk factor registration will be done on a daily basis by the nurses. Reliability checks and time measurements will be completed by the researcher.

Interventions

DEVICERepose®

* Repose® Mattress * Repose® Cushion * Repose® Wedge or Foot Protectors

Sponsors

Frontier Medical Group, UK
CollaboratorUNKNOWN
University Ghent
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
65 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* High risk of pressure ulcers (Braden score \< 12) and/or pressure ulcer category 1 * Currently using alternating-pressure devices * Bedbound (\> 8 hours in bed) or chair bound (\> 8 hours in chair) * Aged \> 65 years

Exclusion criteria

* Pressure ulcer category 2,3,4, deep tissue injury (DTI) or unstageable pressure ulcer * Expected length of stay \< 2 weeks * End of life care * Medical contraindication for use of static air support devices

Design outcomes

Primary

MeasureTime frameDescription
Pressure ulcer incidence (Cat. II+)14 daysDevelopment of at least 1 pressure ulcer Cat. II+ during study period

Secondary

MeasureTime frameDescription
Patient experiences and perceptions using a static air mattress14 daysPatients experiences and perceptions of comfort using static air support devices and alternating-pressure mattresses. Patient acceptability \[tolerance, (sleep) comfort, pain)
Caretakers perceptions of barriers and facilitators to use static air mattress14 daysNurses acceptability \[barriers and facilitators\].
Incidence of incontinence-associated dermatitis (IAD)14 daysDevelopment of at least 1 IAD during study period
Cost of the intervention (Repose) versus the standard care (Alternating)14 daysEconomic measures (from an organizational and patient perspective)

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026