Skip to content

Optimization of Cardiac Pacing Using CardioMEMS

Optimization of Cardiac Pacing Using CardioMEMS

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03581032
Enrollment
30
Registered
2018-07-10
Start date
2017-03-01
Completion date
2019-06-01
Last updated
2018-07-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Brief summary

This study is designed to determine if a simplified technique for cardiac device reprogramming using pulmonary artery pressure (PAP) data in the acute setting holds promise to improve subjective assessments of patient quality of life (QOL), objective measurements of functional capacity, and specific systolic and diastolic echocardiographic indices.

Detailed description

The present study is designed to determine if a simplified technique for cardiac device( CRT) reprogramming using pulmonary artery pressure (PAP) via implanted CardioMEMS device data in the acute setting holds promise to improve subjective assessments of patient quality of life (QOL), objective measurements of functional capacity, and specific systolic and diastolic echocardiographic indices. The protocol requires prospective collection and analysis of echocardiographic data, subjective symptoms (Minnesota Living with Heart Failure Questionnaires), and 6-minute walk distance measurements in patients with implanted biventricular pacemakers / defibrillators who are predominantly ventricularly paced, in normal sinus rhythm, have documented NYHA class 3 Heart Failure, and have implanted pulmonary artery pressure monitors (CardioMEMS, St. Jude Medical CRMD, St. Paul, MN). Data collection will occur at presentation (rest and with ambulation), one month post-reprogramming, and two months after evaluation and / or reprogramming.

Interventions

DEVICEActive reprogam

Reprogram Changes in AV/PV delays

Sponsors

St. Francis Hospital, New York
Lead SponsorOTHER

Study design

Observational model
CASE_CROSSOVER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL

Inclusion criteria

1. Patients have implanted PPM, ICD, or CRT devices and CardioMEMS 2. Patients can ambulate for 6 minutes and lay on a flat surface 3. Patients are paced \> 95% of the time 4. Patients are not in acute CHF and are on a stable medication regimen 5. Patients have adequate echocardiographic windows 6. Patients can consent independently

Exclusion criteria

1. Patients with poor echocardiographic acoustical resolution. 2. Patients with congenital heart disease. 3. Patients with mechanical aortic or mitral valve replacements. 4. Patients with significant mitral annular calcification. 5. Patients with irregular heart rates: atrial fibrillation, supraventricular tachycardia, atrial premature contractions, and ventricular arrhythmia that would preclude data acquisition. 6. Patients unable to remain still secondary to movement disorders or agitation. 7. Inpatient status 8. Patients with poorly controlled HTN (SBP\>160/90

Design outcomes

Primary

MeasureTime frameDescription
Pulmonary artery pressure changes30 daysPrimary endpoint is changes in of pulmonary artery pressures within 30 days in patients who have optimization of pacing devices.

Countries

United States

Contacts

Primary ContactElizabeth S Haag, BSN MPA
elizabeth.haag@chsli.org516 622-4512
Backup ContactRita Jermyn, MD
rita.jermyn@chsli.org516 562-6426

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026