Skip to content

The Degree of Accuracy of Patient-specific PEEK Implant to Restore Chin Deficiency

The Degree of Accuracy of Patient-specific PEEK Implant to Restore Chin Deficiency. Accuracy Study

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03577210
Enrollment
20
Registered
2018-07-05
Start date
2018-09-30
Completion date
2019-10-31
Last updated
2018-07-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chin Microgenia

Keywords

chin deficiency, chin asymmetry

Brief summary

computer guided patient-specific PEEK implant will be used to augment patients with chin deficiency or chin asymmetry.

Detailed description

augmentation genioplasty will be done to patients with chin deficiency or asymmetry. using cone beam CT for each patient and special soft ware MIMICS 15 , patient-specific implant design can be done. PEEK will be milled as CAD-CAM technique to finally get patient specific PEEK implant. with patient is under General anesthesia, the implant will inserted and fixed with titanium screws. closure in two layers will be done.

Interventions

PROCEDUREaugmentation genioplasty

augmentation genioplasty with patient-specific PEEK implant

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult male or female patients. * Patients with retruded chin or with chin asymmetry. * Patients with good oral hygiene.

Exclusion criteria

* Patients that need skeletal procedure in the mandible, other than genioplasty, at the same time of surgery or was done within time period less than 6 months. * Patients with medical condition that may compromise the healing process. * Patients with medical condition that is contraindicated for general anaesthesia. * Presence of pathological lesion related to chin area.

Design outcomes

Primary

MeasureTime frameDescription
degree of accuracy of patient specific peek implant in chin augmentation as virtually planned using Mimics software, measuring unit (mm) mmtwo weeks postoperativedegree of accuracy of patient specific peek implant in chin augmentation as virtually planned using Mimics software, measuring unit (mm) mm

Secondary

MeasureTime frameDescription
patient satisfaction with postoperative chin appearance and pain: Face-Q questionnaire6 months postoperativedegree of patient satisfaction using Face-Q questionnaire with score from 0-100 where 0 shows least degree of satisfaction and 100 shows best degree of satisfaction.

Countries

Egypt

Contacts

Primary Contactsalma h Abd el-Aty, MSc
salmadent@gmail.com0201113999772
Backup Contactsalma h Abd el-Aty, MSc
s7_86@hotmail.com0201005113060

Outcome results

None listed