Skip to content

Effectiveness, Safety and Perceptions With the Use of One LED Blanket Device in the Ambulatory Treatment of Jaundice

Effectiveness, Safety and Perceptions With the Use of One LED Blanket Device in the Ambulatory Treatment of Neonatal Jaundice

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03569254
Acronym
LEDlightT2
Enrollment
64
Registered
2018-06-26
Start date
2016-03-01
Completion date
2017-10-05
Last updated
2018-07-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Jaundice, Neonatal, Phototherapy

Keywords

infant, newborn, devices, treatment, hyperbilirubinemia

Brief summary

Objective: to evaluate the effectiveness, safety and level of satisfaction of parents and healthcare team with one innovative device for phototherapy to which a LED light mesh has been incorporated(a blanket), comparing it with the Ohmeda BiliBlanket Plus®. Methods: randomized controlled clinical trial with preterm or low birth weight infants requiring phototherapy. The study protocol was evaluated and accepted by the San Ignacio Hospital and Pontificia Universidad Javeriana research committee. Informed consent was requested from parents and the authors declared no conflict of interest. Sample size and allocation: using the STATA 12 program, a sample size of 64 patients was calculated(5% losses), 32 for each group, with significance level of 0.05, power of 80% and difference in bilirubin decreasing of at least 0,1 mg/dl/h with standard deviation of 0.14 mg/dl/h. A computer program randomized the allocation to the intervention and the concealment of the assignment was through sealed opaque envelopes. Seric bilirubin levels were taken at the start and at the end of phototherapy. Controls were done every 2 hours with the Bilicheck spectrophotometer device. Axillary temperature was measured at the beginning of phototherapy, at 30 min, 60 min, and every 2 hours during intervention. Physical examination and recording of side effects related were performed. Parents and health personnel answered a survey on comfort and perceptions with the use of the devices at the end of phototherapy. Analysis: Comparison of means was made for the decrease of bilirubin levels and body temperatures and chi-square for incidence of side effects and results of the survey.

Detailed description

Background: Jaundice due to hyperbilirubinemia is the most common entity that requires medical management in neonates. About 50% of full-term newborns and 80% of premature infants develop jaundice. The effectiveness of phototherapy for neonatal jaundice depends on two factors: the spectrum of light emitted and the spectral irradiation of light. An ideal phototherapy device should have a broad light emission surface, in order to cover the maximum of the body surface in the horizontal plane, it should be durable, generate relatively little heat and provide a wavelength and light intensity (radiation) optimal (460-490nm and ≥ 30uw / cm2 / nm). The conventional phototherapy devices use fluorescent lamps that emit heat and require eye protectors, in addition to increasing water losses, which requires a permanent monitoring of vital functions and temperature. Its use imposes hospitalization and consequently mother-child separation, always traumatic. The most recent devices use light emitting diodes (LED light) as the light source. Objective: to evaluate the effectiveness, safety and level of satisfaction of parents and healthcare team with one innovative device for phototherapy to which a LED light mesh has been incorporated (one blanket), comparing it with the Ohmeda BiliBlanket Plus®, used at the Kangaroo Mother Care Program for intermittent ambulatory phototherapy. Methods: randomized controlled clinical trial with preterm or low birth weight infants that required phototherapy according to the guidelines of the American Academy of Pediatrics. The Protocol was evaluated and accepted by the Hospital Universitario San Ignacio and Pontificia Universidad Javeriana research committee. Informed consent was requested from parents and the authors declared no conflict of interest. Sample size and allocation: using the STATA 12 program, a sample size of 64 patients was calculated, 32 for each group, with significance level of 0.05, power of 80% and difference in bilirubin decreasing of at least 0,1 mg/dl/h with standard deviation of 0.14 mg/dl/h and 5% of losses. A computer program randomized the allocation to the intervention and the concealment of the assignment was through sealed opaque envelopes. Seric bilirubin levels were taken at the start and at the end of phototherapy. Controls were done every 2 hours with bilicheck spectrophotometer device. Axillary temperature was measured at the beginning of phototherapy, at 30 min, 60 min, and every 2 hours during intervention. Physical examination, recording of side effects related, mortality and requirement of hospital treatment were performed. Parents and health personnel answered a survey on comfort and perceptions with the use of the devices at the end of phototherapy. Analysis: Comparison of means was made for the decrease of bilirubin levels and body temperatures and chi-square for incidence of side effects, hospitalization, mortality and results of the survey.

Interventions

DEVICENeomedlight Phototherapy Blanket

The NeoMedLight® phototherapy blanket is an innovative new fiber-optic device based on LED light. Its light emitting surface area is 40.5x30 cm or 1200 cm2. The device size is 40.5 x30 cm. It incorporates fiber optic mesh and is protected by a vinyl cover and a disposable liner for patient comfort and hygiene. This device provides therapeutic light (404-515nm) to a wide extension of the body surface area. Its average irradiation footprint is 35uW / cm2 / nm ± 15%. The phototherapy was done intermittently in periods of 2 hours with 1 hour of rest for a total time of 6 hours in kangaroo position.

DEVICEOhmeda-Fiber Optic Phototherapy Blanket

This device is a high performance version of Ohmeda Medical's Biliblanket that uses a fiber optic cable to deliver light from a high-intensity lamp to a device composed of a fiber optic fabric. The device has a disposable liner and is left in direct contact with the patient. The patient is exposed to a light with a wavelength between 400 and 550 nanometers. The phototherapy system consists of a light emitting unit, a fiber optic cable four feet long (121.9 cm) and a lightweight mattress. It has two available sizes: 4.38 x 9.38 inches (11.12 x 23.83 cm) and 4.00 x 6.00 inches (10.16 x 15.2 cm).

Sponsors

Hospital Universitario San Ignacio
CollaboratorOTHER
Nathalie Charpak
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Parallel assignment randomized controlled clinical trial with preterm or low birth weight infants who have low risk hyperbilirubinemia requiring phototherapy

Eligibility

Sex/Gender
ALL
Age
No minimum to 1 Months
Healthy volunteers
No

Inclusion criteria

* Low Risk Hyperbilirubinemia requiring phototherapy according to the guidelines of the American Academy of Pediatrics and recommendations for management of premature infants under 35 weeks, adopted by the Kangaroo Mother Care Ambulatory Program. * Start of jaundice at a chronological age greater than 48 hours. * Bilirubin level ≤18 mg / dL * Knowledge of blood groups of mother and child. * Parents are required to sign informed consent where they agree to participate in the study.

Exclusion criteria

* Parents without availability to stay in the Kangaroo Mother Care Program for at least 6 hours. * Extensive skin lesions due to burns or sloughing at the physical examination prior to entering the study.

Design outcomes

Primary

MeasureTime frameDescription
Bilirubin change rate in mg/dl/hthrough study completion, an average of 6 hoursBilirubin lowering rate (initial seric bilirubin- final seric bilirubin/time of phototherapy).

Secondary

MeasureTime frameDescription
Incidence of skin lesions related to phototherapythrough study completion, an average of 6 hoursrash, burns, etc... related to phototherapy
Incidence of dehydration related to phototherapythrough study completion, an average of 6 hoursDehydration documented with physical examination and weight
Incidence of diarrhea related to phototherapythrough study completion, an average of 6 hoursDocumented diarrhea
Incidence of other side effects related to phototherapythrough study completion, an average of 6 hoursOther effects recorded in clinic history related to phototherapy
Patient temperature during phototherapythrough study completion, an average of 6 hoursAxillary temperatures at 30 min, 60 min, 1 hour, 2 hours, 4 hours and 6 hours of phototherapy.
Perceptions of the health team with the use of the devicesAt study completion, an average of 6 hours.Comfort cleaning and using the device and comfort with light, heat, humidity, and feeding and taking care of the baby. The investigators did a validated survey at the end of treatment using a Likert scale(1-7): 1=uncomfortable. 7=comfortable, 4=indifferent
Hospitalization for hyperbilirubinemiaBetween beginning of treatment and 72 hours afterRate of hospitalization for hyperbilirubinemia
MortalityBetween beginning of treatment and 72 hours afterRate of mortality related to treatment
Perceptions of parents with the use of devicesAt study completion, an average of 6 hours.Comfort with heat, humidity, breastfeeding, proximity and possibility of contact with the baby. The investigators did a validated survey at the end of treatment using a Likert scale(1-7): 1=uncomfortable. 7=comfortable. 4=indifferent

Countries

Colombia

Outcome results

None listed