Skip to content

Feasibility Trial on ACURATE™ Transapical Implantation in Patients With Severe Symptomatic Aortic Stenosis (2009-01)

Feasibility Trial on ACURATE™ Transapical Implantation in Patients With Severe Symptomatic Aortic Stenosis

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03567278
Acronym
TA-FIM
Enrollment
40
Registered
2018-06-25
Start date
2009-11-30
Completion date
2015-09-30
Last updated
2018-06-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Stenosis Symptomatic

Keywords

Severe Symptomatic Aortic Valve Stenosis

Brief summary

Feasibility Trial on the ACURATE TA™ transapical implantation in patients presenting severe symptomatic aortic stenosis to collect human feasibility data pertaining to the safety and performance of the device.

Detailed description

A single arm, prospective, multicenter, open trial up to 5 year follow-up with the SYMETIS ACURATE TA™ which is an aortic bioprosthesis for minimal invasive implantation via transapical access to treat patients with severe symptomatic aortic stenosis where conventional aortic valve replacement (AVR) via open heart surgery is considered to be associated with high surgical risk for evaluating the feasibility and performance of the implantation and the safety at 30-Day follow-up.

Interventions

ACURATE TA™ Transapical Aortic Bioprosthesis is intended for subjects with severe symptomatic Aortic Stenosis and are considered high risk for surgical conventional Aortic Valve Replacement surgery.

Sponsors

Symetis SA
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Medical Device Study

Eligibility

Sex/Gender
ALL
Age
75 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients older than 75 years; * Additive EuroSCORE \> 9 and/or STS \> 9%; * Severe symptomatic AS assessed by echocardiography, documented by a derived mean gradient \> 40mmHg,and a native Aortic Valve Area (AVA) \< 0.8 cm² or Aortic Valve Area Index (AVAI) \< 0.6 cm²/m²; * NYHA Functional Class \> II; * Aortic annulus (AAn) diameters between and including 21 mm up to 27 mm (21mm ≤ AAn ≤27mm) by transoesophageal echocardiography; * Sinotubular junction (STJ) higher than 1,1times the native aortic annulus diameter (AAn) \[STJ\>1.1xAAn\] AND STJ\<45mm by transoesophageal echocardiography; * Patient understands the implications of participating in the study and provides signed informed consent

Exclusion criteria

* Congenital unicuspid or bicuspid aortic valve; * Severe eccentricity of calcification; * Severe mitral regurgitation (\> 2°); * Pre-existing prosthetic heart valve in any position and /or prosthetic ring; * Severe transapical access problem, non-reachable LV apex; * Previous surgery of the LV using a patch, such as the Dor procedure; * Presence of apical LV thrombus; * Echocardiographic evidence of intracardiac mass, thrombus, or vegetation; * Acute Myocardial Infarction (AMI) within 1 month prior to the procedure; * PCI within 1 month prior to the procedure; * Previous Transient Ischemic Accident (TIA) or stroke in the last 3 months; * Untreated clinically significant CAD requiring revascularization; * Hemodynamic instability: systolic pressure \<90mmHg without afterload reduction, shock, need for inotropic support or intra-aortic balloon pump; * Severe left ventricular dysfunction with a LV Ejection Fraction (LVEF) \< 25% by echocardiography; * Calcified pericardium; * Septal hypertrophy; * Primary Hypertrophic Obstructive Cardiomyopathy (HOCM); * Active infection, endocarditis or pyrexia; * Active peptic ulcer or Gastrointestinal (GI) bleeding within the past 3 months; * Significant hepatic involvement (Child \> B); * Major lung disease (FEV \< 0.8 or FEV1% \< 30% of normal); * Pulmonary hypertension; * History of bleeding diathesis or coagulopathy; * Hematologic disorder (WBC\<3000mm3, Hb\<9g/dL, platelet count \<50000 cells/ mm3); * Serum creatinine level greater than 3.0 mg/dL or chronic renal failure requiring dialysis; * Neurological disease severely affecting ambulation or daily functioning, including dementia; * Other procedure scheduled at the same time, whether surgery or percutaneous approach; * Emergency procedure; * Life expectancy \< 12 months due to non-cardiac co-morbid conditions; * Known hypersensitivity/contraindication to any study medication, contrast media, or nitinol; * Currently participating in an investigational drug or another device study

Design outcomes

Primary

MeasureTime frameDescription
Safety endpoint30 daysRate of Major Adverse Valve-Related Events (MAVRE) related to ACURATE

Secondary

MeasureTime frameDescription
Performance endpointUp to 24-hours post-procedureStable ACURATE placement at intended site as assessed by angiography
Mortality30 days, 60 days, 3 months, 6 months and 12 monthsFreedom from Death at follow-up
MAVRE at follow-updischarge or 7 days, 3 months, 6 months and 12 monthsRate of MAVRE at follow-up
MACCE or Major Adverse Cardiac and Cerebrovascular Event1 month, 3 months, 6 months and 12 monthsRate of MACCE at follow up

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026