Skip to content

Evaluation of Changes of Venous Return After Spinal and Epidural Analgesia and Anesthesia by Ultrasound Guided Vena Cava Diameter Measurement

Evaluation of Changes of Venous Return After Spinal and Epidural Analgesia and Anesthesia by Ultrasound Guided Vena Cava Diameter Measurement

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03555799
Enrollment
42
Registered
2018-06-14
Start date
2018-05-18
Completion date
2019-06-15
Last updated
2019-07-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypotension, Orthostatic, Pregnancy Related

Brief summary

The investigators propose this study to test the hypotheses that inferior vena cava (IVC) diameter can predict hypotension after labor analgesia (epidural, combined spinal-epidural) and neuraxial anesthesia for cesarean section (epidural, combined spinal-epidural and spinal block) in full-term pregnant patients.

Detailed description

After approval by the Institutional Review Board and patient consent, term pregnant patients (\>37 week gestation) admitted to the obstetric service of Augusta University Medical Center, who require administration of neuraxial analgesia for labor or regional anesthesia for cesarean section, will be included in the study. The consent will be obtained by the attending, resident or medical student in which the investigators will explain to the patient the procedure, benefit, risk, cost and, confidentiality. The investigators plan to get the consent immediately after the patient arrived at the unit to avoid any interference with the delivery process. If the patient needs to go to an emergency cesarean section. This patient is not going to be included in the study. Demographic variables (age, BMI, Gravity, parity and gestation weeks) and hemodynamic variables (MAP and HR) will be recorded. All patients will be lying in supine position, breathing spontaneously. The ultrasound examination will be performed before commencement of the neuraxial procedure and will be repeated two minutes after administration of the neuraxial anesthetic. Ultrasound measurements will be made with a Sonosite Edge (Sonosite Inc. USA) machine and a C60X curved linear phased array transducer (Sonosite Inc.) set to abdominal mode. All measurements will be made by two attending anesthesiologists (ERP and AR) who have experience in transthoracic echocardiography, and a resident who receives the basic instruction to measure IVC diameter. The medical student will be present during the procedure and will ensure that the study echocardiographic views are taken. The IVC will be visualized using a paramedian long-axis view via a subcostal approach according to guidelines of the American Society of Echocardiography. A two-dimensional image of the IVC will be obtained and pulsed wave Doppler will be used to differentiate from the aorta. Variations in IVC diameters will be assessed with M-mode applied 2 cm. distal to the right atrium. To ensure consistent measurements, each operator will take three images. The best quality images are chosen. Maximum and minimum IVC diameters during a single respiratory cycle will be measured.

Interventions

Abdominal ultrasound to identify IVC between hepatic veins and right atrium. Measurement of dimensions throughout respiratory cycle (before and after labor epidural)

Sponsors

Augusta University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Pregnant patients \>37 weeks of gestation 2. Indication for neuraxial labor analgesia or regional anesthesia for cesarean section 3. Age older than 18 years 4. Pregnancy without diagnosed comorbidities

Exclusion criteria

1. Unwillingness to participate in the study 2. Diagnosis of Hypertensive disorders of pregnancy 3. Diagnosis of cardiopulmonary disease 4. Allergy to US gel

Design outcomes

Primary

MeasureTime frameDescription
IVC diameter10 minutesIVC diameter in centimeters during respiratory cycle

Secondary

MeasureTime frameDescription
Mean arterial pressure30 minutesMean arterial pressure
Nausea30 minutesNausea

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026