Skip to content

CEUS Evaluation of Bowel Perfusion in Necrotizing Enterocolitis

Evaluation of Bowel Perfusion With Contrast-Enhanced Ultrasound in Necrotizing Enterocolitis

Status
Terminated
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03549507
Enrollment
1
Registered
2018-06-08
Start date
2020-11-04
Completion date
2024-05-07
Last updated
2024-11-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bowel Ischemic, Necrotizing Enterocolitis of Newborn

Keywords

Ultrasound, Contrast-enhanced ultrasound

Brief summary

There is no bedside imaging technique that can quantify dynamic bowel perfusion with high soft tissue contrast and sensitivity in necrotizing enterocolitis (NEC). Our goal is to assess the feasibility of utilizing contrast-enhanced ultrasound (CEUS) in bedside monitoring of bowel perfusion in NEC. Patients with suspected or diagnosed NEC will be recruited for the study. Following parental consent, the subject will undergo CEUS, performed separately from any clinically indicated conventional US, in the ICU. Subjects will be scanned with CEUS at two different time-points (at the time NEC is first suspected or diagnosed and at time of MRI scan). The CEUS scans will be interpreted by the sponsor-investigator. The study will be conducted at one site, The Children's Hospital of Philadelphia. It is expected that up to 100 subjects will be enrolled per year, for up to two years, for a total enrollment of up to 200 subjects.

Detailed description

Early detection of ischemia and necrotic bowel which leads to perforation is vital in improving morbidity and mortality associated with NEC. Abdominal radiography, the standard imaging algorithm for monitoring of NEC, has a low sensitivity of 40% in the diagnosis of severe NEC with necrotic bowel. There is a dire need to introduce better imaging tools such as CEUS to the clinical setting that can detect NEC at an early stage and prompt therapeutic implementation. CEUS enables safe, serial monitoring of dynamic quantification of bowel perfusion at the bedside. Sulfur hexafluoride lipid-type A microspheres (LumasonTM, Bracco Inc) is an FDA-approved ultrasound contrast agent. The study duration per subject will be approximately 15 minutes including the time to prepare LumasonTM contrast agent and perform the CEUS, as well as the 60 minute monitoring period after the first and second injection of LumasonTM. CEUS will be performed at the time of suspected or diagnosed NEC, and at the time of surgery (for subjects undergoing surgery as part of clinical care) or at short-term follow-up of clinical condition (approximately 1 week after the first scan) for a total of two CEUS exams of 1 hour and 15-minute duration each. Injection of LumasonTM contrast agent will be performed via the existing peripheral intravenous line or central line using the FDA-recommended dose of up to 0.03 mg/kg. Contrast-agent injection will be performed twice per CEUS scan to ensure image quality and test reproducibility. In the case of more stable patients without an IV line, a peripheral IV line will be started to conduct the investigational CEUS. Two bolus injections will performed to evaluate for dynamic bowel perfusion and several 2-minute cine clips as well as static images will be acquired during the exam. Qualitative analysis with visual assessment and quantitative analysis of the acquired CEUS scans will be performed and interpreted by the PI. The scans will be assessed for diagnostic quality of images, artifacts encountered, and the presence of additional contributory diagnostic information.

Interventions

Injection of Sulfur hexafluoride lipid-type A microspheres (Lumason) contrast agent will be performed via the existing peripheral intravenous line using the FDA-recommended dose of 0.03 mg/kg. Two bolus injections will be performed to evaluate for dynamic bowel perfusion and several 2-minute cine clips as well as static images will be acquired during the exam.

Sponsors

Bracco Diagnostics, Inc
CollaboratorINDUSTRY
Children's Hospital of Philadelphia
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
0 Years to 18 Months
Healthy volunteers
No

Inclusion criteria

1. Males and females aged 1.5 years or younger 2. Post menstrual age of 29 weeks or older 3. Patients with suspected or diagnosed necrotizing enterocolitis 4. Patient in the Children's Hospital of Philadelphia (CHOP) neonatal intensive care unit (NICU) or pediatric intensive care unit (PICU) 5. Parental permission

Exclusion criteria

1. Medical history of Lumason hypersensitivity 2. Hemodynamic instability as defined by rapid escalation of cardiopulmonary support in the past 12-24 hours, as defined by the clinical care team including ≥ 1 intensive care physician not part of the study team 3. Pulmonary insufficiency as defined by FiO2 requirements of \>40% and/or subjects with pulmonary hypertension requiring nitric oxide

Design outcomes

Primary

MeasureTime frameDescription
Early Detection of Altered Bowel Perfusion Using CEUS2 yearsComparison of bowel perfusion between normal subjects (those with suspected or at risk of necrotizing enterocolitis but turn out to be normal on imaging and clinical evaluation) versus NEC patients

Secondary

MeasureTime frameDescription
Number of Participants With Completed CEUS Exams, Categorized by Diagnostic-Quality Scoring System2 yearsScoring system of non-diagnostic (1), moderate artifacts degrading diagnostic quality (2), mild artifacts without degradation of diagnostic quality (3), and diagnostic (4).

Countries

United States

Participant flow

Participants by arm

ArmCount
Contrast-enhanced Ultrasonography
Intravenous administration of contrast agent Sulfur hexafluoride lipid-type A microspheres before performing contrast-enhanced ultrasound (CEUS). In pediatric patients, after reconstitution 0.03 mL per kg is administered intravenously. The weight-based dose of 0.03 mL per kg will be repeated one time during a single examination. Following each injection, an intravenous flush of 0.9% Sodium Chloride is injected. The study duration per subject will be approximately 15 minutes including the time to prepare the contrast agent and perform the CEUS, as well as the 60 minute monitoring period after the first and second injection (if there are two injections of contrast) of the contrast agent. Sulfur hexafluoride lipid-type A microspheres: Injection of Sulfur hexafluoride lipid-type A microspheres (Lumason) contrast agent will be performed via the existing peripheral intravenous line using the FDA-recommended dose of 0.03 mg/kg. Two bolus injections will be performed to evaluate for dynamic bowel perfusion and several 2-minute cine clips as well as static images will be acquired during the exam.
1
Total1

Baseline characteristics

CharacteristicContrast-enhanced Ultrasonography
Age, Categorical
<=18 years
1 Participants
Age, Categorical
>=65 years
0 Participants
Age, Categorical
Between 18 and 65 years
0 Participants
Age, Continuous47 Days
STANDARD_DEVIATION 0
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
0 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
1 Participants
Region of Enrollment
United States
1 participants
Sex: Female, Male
Female
0 Participants
Sex: Female, Male
Male
1 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 1
other
Total, other adverse events
0 / 1
serious
Total, serious adverse events
0 / 1

Outcome results

Primary

Early Detection of Altered Bowel Perfusion Using CEUS

Comparison of bowel perfusion between normal subjects (those with suspected or at risk of necrotizing enterocolitis but turn out to be normal on imaging and clinical evaluation) versus NEC patients

Time frame: 2 years

Population: One subject was enrolled, therefore, no comparison was possible. The enrolled subject presented with medical NEC. Main reasons for lack of enrollment were the presence of clinical instability and/or pulmonary insufficiency/hypertension.

ArmMeasureGroupValue (NUMBER)
Bowel Contrast-enhanced UltrasonographyEarly Detection of Altered Bowel Perfusion Using CEUSPatients with NEC who underwent CEUS examination1 Number of patients
Bowel Contrast-enhanced UltrasonographyEarly Detection of Altered Bowel Perfusion Using CEUSPatients without NEC who underwent CEUS examination0 Number of patients
Secondary

Number of Participants With Completed CEUS Exams, Categorized by Diagnostic-Quality Scoring System

Scoring system of non-diagnostic (1), moderate artifacts degrading diagnostic quality (2), mild artifacts without degradation of diagnostic quality (3), and diagnostic (4).

Time frame: 2 years

Population: Evaluation of CEUS diagnostic quality

ArmMeasureGroupValue (NUMBER)
Bowel Contrast-enhanced UltrasonographyNumber of Participants With Completed CEUS Exams, Categorized by Diagnostic-Quality Scoring SystemNon-diagnostic0 Number of participants
Bowel Contrast-enhanced UltrasonographyNumber of Participants With Completed CEUS Exams, Categorized by Diagnostic-Quality Scoring SystemMild artifacts without degradation of diagnostic quality0 Number of participants
Bowel Contrast-enhanced UltrasonographyNumber of Participants With Completed CEUS Exams, Categorized by Diagnostic-Quality Scoring SystemModerate artifacts degrading diagnostic quality1 Number of participants
Bowel Contrast-enhanced UltrasonographyNumber of Participants With Completed CEUS Exams, Categorized by Diagnostic-Quality Scoring SystemDiagnostic0 Number of participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026