Skip to content

Patients Radiation Exposure in Percutaneous Transhepatic Biliary Drainage (PTBD) Procedures

Retrospective Multicenter Study on Patients Radiation Exposure in Percutaneous Transhepatic Biliary Drainage (PTBD) Procedures.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03538782
Enrollment
600
Registered
2018-05-29
Start date
2018-03-15
Completion date
2018-10-15
Last updated
2018-10-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Radiation Exposure

Keywords

percutaneous biliary drainage, radiation exposure

Brief summary

Percutaneous transhepatic biliary drainage (PTBD) procedures are associated with an elevated radiation exposure for the patient. In the recently published guideline of the Federal Office for Radiation Protection in Germany diagnostic reference levels (DRLs) for dose area products (DAP) are not defined for PTBD procedures due to insufficient data. The aim of this retrospective study is to give a nation-wide survey on patients radiation exposure in different PTBD procedures considering factors that may have an impact on increased radiation exposure like fluoroscopic-guided versus ultrasound-guided bile duct puncture.

Detailed description

Percutaneous transhepatic biliary drainage (PTBD) procedures are associated with an elevated radiation exposure for the patient. Usually, radiation exposure in radiological interventions is measured by the dose area product (DAP). Diagnostic reference levels (DRLs) are based on the third quartiles (Q3) of the pooled dose area product (DAP) for the known interventional procedures. They have been introduced in the 1980s by the International Commission on Radiological Protection's (ICRP's) to reduce patients radiation exposure. In the recently published guideline of the Federal Office for Radiation Protection in Germany in 2016 DRLs are not defined for PTBD procedures due to insufficient data. Procedure complexity due to different techniques, patient anatomy, lesion characteristics and disease severity makes it difficult to define DRLs in this fluoroscopy-guided intervention. The ICRP recently published some recommendations on DRLs in medical imaging including radiological interventions. As DRLs are often missing in this field, it was suggested to analyze national data sets comprising dosimetric data from a large number of facilities. The aim of this retrospective study is to give a nation-wide survey on patients radiation exposure in different PTBD procedures considering factors that may have an impact on increased or decreased radiation exposure like fluoroscopic-guided versus ultrasound-guided bile duct puncture. A questionnaire was sent to 200 gastroenterological and radiological departments in university and non-university hospitals to analyze the last 10 - 30 consecutively performed PTBD procedures.

Interventions

The initial puncture of the bile duct with an access needle is performed by ultrasound guidance or by fluoroscopic guidance. After injection of the radiopaque contrast media into the bile duct system the rest of the examination is performed by fluoroscopic guidance. All different PTBD procedures are analyzed: insertion, exchange or removal of a plastic catheter, metal stent implantation, PTBD with cholangioscopy, PTBD with ballon dilatation, PTBD with lithotrypsy or diagnostic percutaneous transhepatic cholangiography.

Sponsors

The Federal Office for Radiation Protection, Germany
CollaboratorOTHER_GOV
Theresienkrankenhaus und St. Hedwig-Klinik GmbH
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 10 up to 30 consecutively performed PTBDs are documented in the study center * body weight of the examined patients is about 60 - 80 kilogramms * returned questionaire is complete in regard to DAP, fluoroscopy time, number of still images, characters of the intervention, characterization of the fluoroscopy device (manufacturer, date of first registration)

Exclusion criteria

* the study center performs less than 10 PTBDs/year * returned questionaire is incomplete

Design outcomes

Primary

MeasureTime frameDescription
Radiation ExposureFrom the beginning of the radiological examination until the end the examination (15 - 180 minutes)Radiation Exposure for the patient is measured by the dose area product (cGy x cm2 resp.µGy x∙m2)

Secondary

MeasureTime frameDescription
Fluoroscopy timeFrom the beginning of the radiological examination until the end the examination (15 - 180 minutes)Accumulated fluoroscopy time for the complete examination (minutes)
Number of imagesFrom the beginning of the radiological examination until the end the examination (15 -180 minutes)Number of still images which are produced during the whole examination (n)

Countries

Germany

Outcome results

None listed