Skip to content

Reaching 90% HIV Suppression: The Role of POC Viral Load Monitoring in Nigeria

Reaching 90% Target of HIV Viral Suppression: The Role of Point-of-Care Viral Load Monitoring in Resource-Constrained Settings in Nigeria

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03533868
Acronym
POC
Enrollment
543
Registered
2018-05-23
Start date
2018-04-09
Completion date
2021-02-28
Last updated
2021-04-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

HIV/AIDS

Keywords

Point-of-care, Viral load monitoring, Nigeria

Brief summary

The UNAIDS 90-90-90 goals represents an ambitious strategy to end the acquired immunodeficiency syndrome (AIDS) epidemic by 2020 \[UNAIDS, 2015\]. While viral load (VL) quantification is the gold standard of HIV treatment monitoring, it is only routinely available and employed in resource-rich countries. The use of an affordable, reliable, point-of-care (POC) VL assay has been considered a game-changer, where increased access, minimal lab worker training, and same day results could be addressed in a single solution. To date, POC VL assays have been evaluated by their manufacturers with reference panels of samples with some in-country laboratory evaluations. While these are appropriate and critical first steps, it is also important to evaluate the impact of this new technology against the standard of care (SOC) method of VL monitoring in an actual resource-limited setting. Nigeria has the second highest burden of HIV in the world, with an estimated 3.2 million infected and serves as a relevant setting for testing feasibility and efficacy of POC VL monitoring \[UNAIDS, 2016\]. In order to present the case for implementing the use of POC VL testing across Nigeria, data on the acceptability, feasibility and efficacy of using POC testing for VL monitoring are needed. To address this need, the investigators have designed a randomized controlled trial comparing POC VL to monitoring to the SOC, which follows the Nigerian National Guidelines, to provide operational evidence for implementation of POC VL testing in Nigeria. This trial is aimed at testing the hypothesis that using POC versus SOC VL monitoring in HIV-infected patients newly initiating ART will improve overall ART outcomes, increase ART adherence and program retention rates, and result in faster switches to second-line treatment of patients failing first-line ART.

Detailed description

The investigators will conduct an un-blinded randomized implementation trial comparing POC VL monitoring, using the Cepheid Gene Xpert HIV-1 VL®, to SOC VL monitoring, using the Roche AmpliPrep/COBAS Taqman system. The trial will be conducted at two sites in Plateau State, Nigeria. ART-naïve patients initiating ART will be randomized on a 1:1 basis to the SOC VL monitoring control arm or the POC VL monitoring arm. VL monitoring will occur according to the current Nigerian ART guidelines-recommended algorithm, with the addition of a baseline VL test. For the month 6 and 12 visits, patients that are enrolled in the POC VL monitoring arm will be provided their VL results. Participants in the SOC arm will receive their Roche VL test results after the results become available per SOC protocol. All other aspects of their HIV care and treatment will be identical to services that they would normally receive at these treatment centers. The investigators will follow all patients up through their Month 12 follow-up visit. At trial exit, the investigators will ask patients, caregivers of patients under the age of 18 years, and providers for their participation in surveys on the operational performance and acceptability of the POC versus SOC VL monitoring. Following that time point, the patients will continue receiving HIV care and treatment utilizing the SOC procedures for the clinic.

Interventions

DIAGNOSTIC_TESTPoint-of-care viral load monitoring test

For enumerating viral load for patients in the POC arm, we will use the Cepheid Xpert® HIV-1 Viral Load test, a quantitative assay with a quantification range of 40 to 10,000,000 copies/mL. Based on the GeneXpert® technology, Xpert HIV-1 VL automates the test process, including RNA extraction, purification, reverse transcription and cDNA real-time quantitation in one fully integrated cartridge. The pre-loaded disposable single-use cartridges provide a visual read-out within 90 minutes. The assay requires 1 mL of plasma using a precision pipette (1.2 mL using a transfer pipette).

Sponsors

Jos University Teaching Hospital
CollaboratorOTHER
Centers for Disease Control and Prevention
CollaboratorFED
Harvard School of Public Health (HSPH)
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Intervention model description

Patients will be randomized to have their viral load monitored by either the standard of care or point-of-care method at their follow-up clinical visits up to 12 months.

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

-All HIV-infected patients newly initiating ART

Exclusion criteria

* Previous ARV experience * Pregnant

Design outcomes

Primary

MeasureTime frameDescription
Proportion of patients with VL<1000 copies/mL at month 12 post-initiation of ART (range 11-15 months) in SOC VL versus POC VL12 months (range 11-15 months)Proportion of patients that have undetectable viral load at the end of observation (month 12) will be compared by treatment arm

Secondary

MeasureTime frameDescription
Difference in ART adherence patterns in patients in the SOC versus POC VL armsFrom ART initiation to month 12Average percent adherence will be computed using patient refill data that are stored electronically. The average will be calculated as number of days supplied over total days in the given time interval, adjusting for amount of medication that should remain since last refill, computed based on amount supplied during the previous visit minus the number of days since the last visit.
Difference in loss to follow-up rates by 12 months post-initiation of ART between patients monitored with SOC versus POC VL armsMonth 12LTFU at month 12 is defined as not having made any refill pick-ups or clinical visits since 9-month post-initiation of ART.
Impact of trial site on differences in virologic suppression rates within patients receiving SOC VL monitoringMonth 12Comparison of data from two different trial sites
Difference in time from ART initiation to the confirmation of virologic failure in SOC versus POC VL monitoring armsART Initiation to Month 12Subset analysis in those that experienced virologic failure (confirmed)
Difference in time from ART initiation to switch to 2L treatment in patients in VF in SOC versus POC VL monitoring armsART Initiation to Month 12Subset analysis in those that experienced virologic failure (confirmed)
Difference in HIV DRM patterns in patients failing 1L ART in the SOC versus POC VL monitoring armMonth 12Subset analysis in those that experienced virologic failure (confirmed)
Difference in time from specimen collection to availability of VL results in patient charts in SOC versus POC VL monitoring armsAll follow-up visits at which VL monitored up to Month 12Comparison of time from specimen collection to the time the result is entered into the patient chart by treatment arm
Difference in time from lab confirmation of first unsuppressed VL to adherence counseling provided and switch to 2L in SOC versus POC VL monitoring armsAll follow-up visits at which VL monitored up to Month 12Subset analysis in those that experienced virologic failure (confirmed)
Health care worker (HCW) satisfaction level with POC versus SOC VL monitoringMonth 12Health care workers will complete a standardized survey querying about their satisfaction with the POC assay. The survey uses a scale measuring agreement level. The scale ranges from 0 to 5 where 0=not applicable, 1=strongly disagree and 5=strongly agree
POC VL arm patient satisfaction with POC vs SOC VL testingMonth 12POC VL arm patients will be queried using a standardized survey about their satisfaction with the POC VL assay. The survey uses a scale measuring agreement level. The scale ranges from 0 to 5 where 0=not applicable, 1=strongly disagree and 5=strongly agree.
Difference in time from specimen collection to delivery of VL results to patient in SOC versus POC VL monitoring armsAll follow-up visits at which VL monitored up to Month 12Comparison of time from specimen collection to the time the result is verbally conveyed to the patient by their clinician by treatment arm

Countries

Nigeria

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 3, 2026