Adhear Bone Conduction System

Comparative Study of Non-invasive Adhear Bone Conduction System to Traditional Bone Conduction Hearing Devices

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03533686
Enrollment
66
Registered
2018-05-23
Start date
2018-04-26
Completion date
2022-03-18
Last updated
2023-08-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hearing Loss, Conductive, Hearing Loss, Unilateral

Brief summary

The purpose of this research study is to learn about the hearing outcomes of adult and pediatric patients who are treated with or are candidates for bone conductive devices (also termed BAHA). Hearing outcomes will also be assessed with a second audio processor device called the Adhear System.

Interventions

DEVICEAdhear Bone Conduction System

Non-invasive bone conduction hearing device using adhesive

DEVICEBone anchored hearing aid (BAHA)

Non-invasive bone conduction hearing device using a headband

Sponsors

Med-El Corporation
CollaboratorINDUSTRY
University of Miami
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Participants who are enrolled in Aims 3 are part of a cross-over design. Participants in this group will be randomly assigned to either standard of care followed by Adhear, or Adhear followed by standard of care.

Eligibility

Sex/Gender
ALL
Age
2 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Aims 1 and 2: * Adult English speaking patients who are experienced users of Bone Anchored Implants (BAIs) for the indication of either single sided deafness or conductive hearing loss. * Experienced will be defined as greater than 6 months of device use and no intermittent function of the device within 2 weeks of enrollment. * Subjects will be limited to those who have normal hearing by bone conduction defined as a pure tone average of 25 dBHL or better at 500, 1000, 2000, & 3000 Hz in at least one ear. Aim 3: * English speaking children 5 to 17 years of age and their primary guardian who present to the clinic for treatment by BAI on a headband device for the indications of single sided deafness or conductive hearing loss. * Subjects will be limited to those who have no prior use of a BAI or bone conduction hearing device, normal hearing by bone conduction defined as a pure tone average of 25 dBHL or better at 500, 1000, 2000, & 3000 Hz in at least one ear. For those children where this cannot be definitively established, children will be included who display clinical signs of normal bone conduction hearing beyond a reasonable doubt and may include such evidence as (but not limited to): auditory brainstem response, speech awareness thresholds, visual reinforcement audiometry, conditioning play audiometry, CT scans, etc.) Aim 3 a & b: * Pediatric bilateral or unilateral conductive hearing loss patients who are between the ages of 2 and 17 years of age * Pediatric participants who are currently managed by the University of Miami with a bone conduction device attached to a softband.

Exclusion criteria

Aims 1 & 2: * Non-English speakers * Participants reporting allergies to adhesives or highly reactive skin. Aim 3: * Pediatric participants who are non-English speakers. * Children who have previous experience with a BAI or bone conduction hearing device will not be included for study. * Pediatric participants reporting allergies to adhesives or highly reactive skin. Aims 3a & 3b: * Pediatric participants who are non-English speakers. * Pediatric participants reporting allergies to adhesives or highly reactive skin.

Design outcomes

Primary

MeasureTime frameDescription
Aided Hearing Thresholds for Single Sided DeafnessDay 1Aided-hearing thresholds represent the softest sound that the participant can hear inside the audiometric test booth when using a hearing device. Aided hearing thresholds were measured using the participant's own device on their abutment and the Adhear device in the test booth on day 1. Hearing thresholds were measured in hertz.
Aided Hearing Thresholds for Conductive Hearing LossDay 1Aided-hearing thresholds represent the softest sound that the participant can hear inside the audiometric test booth when using a hearing device. Aided hearing thresholds were measured using the participant's own device on their abutment and the Adhear device in the test booth on day 1. Hearing thresholds were measured in hertz.
Aided Hearing ThresholdsDay 14 of the interventionAided-hearing thresholds represent the softest sound that the participant can hear inside the audiometric test booth when using a hearing device. Aided hearing thresholds were measured using a traditional bone conduction device on a softband and the Adhear device in the test booth on day 14. Hearing thresholds were measured in hertz.

Secondary

MeasureTime frameDescription
Participant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Day 1Custom Subjective Device Questionnaire measured auditory, social emotional, and device satisfaction as a composite score using a Likert scale. Likert score range was 1-4. Higher scores denoted positive responses. The reported values represent an average across the multiple domains of the questionnaire.
Aided Speech-in-noise Performance in Participants With Single-sided DeafnessDay 1Aided speech-in-noise performance is the ability to identify spoken words when background noise is present while using a hearing device. Aided speech-in-noise performance was measured using the participant's own device on their abutment and the Adhear device in the test booth on day 1. Aided speech-in-noise performance was measured in decibels.
Participant Satisfaction With Adhear at Day 28 (Aim 3b)Day 28Custom Subjective Device Questionnaire measured auditory, social emotional, and device satisfaction as a composite score using a Likert scale. Likert score range was 1-4. Higher scores denoted positive responses. The reported values represent an average across the multiple domains of the questionnaire.
Participant Satisfaction With AdhearDay 14Custom Subjective Device Questionnaire measured auditory, social emotional, and device satisfaction as a composite score using a Likert scale. Likert score range was 1-4. Higher scores denoted positive responses. The reported values represent an average across the multiple domains of the questionnaire.
Aided Speech in Noise Performance in Participants With Conductive Hearing LossDay 1Aided speech-in-noise performance is the ability to identify spoken words when background noise is present while using a hearing device. Aided speech-in-noise performance was measured using the participant's own device on their abutment and the Adhear device in the test booth on day 1. Aided speech-in-noise performance was measured in decibels.
Aided Speech in Noise Performance in Participants With Single-sided DeafnessDay 14Aided speech-in-noise performance is the ability to identify spoken words when background noise is present while using a hearing device. Aided speech-in-noise performance was measured using the participant's own device on a softband and the Adhear device in the test booth on day 14. Aided speech-in-noise performance was measured in decibels.

Countries

United States

Participant flow

Participants by arm

ArmCount
Single-Sided Deafness Adult (Aim1) Group
Adult participants with single-sided deafness and are experienced bone conduction device users (6 months minimum of bone conduction device use and no intermittent use within the last 2 weeks) with an abutment implant will be provided with the Adhear system for 2 weeks (plus up to 90 days). Adhear Bone Conduction System: Non-invasive bone conduction hearing device using adhesive
9
Conductive Hearing Loss Adult (Aim 2) Group
Adult participants with conductive hearing loss and are experienced bone conduction device users (6 months minimum of bone conduction device use and no intermittent use within the last 2 weeks) with an abutment implant will be provided with the Adhear system for 2 weeks (plus up to 90 days). Adhear Bone Conduction System: Non-invasive bone conduction hearing device using adhesive
3
Adhear Followed by BAHA (Aim 3) Group
Pediatric participants (aged 5-17 years) and their parents with conductive hearing loss or single-sided deafness who have not previously used a bone conduction device, will be provided with the Adhear system for 3 weeks (plus up to 90 days) followed by bone anchored hearing aid (BAHA) for another 3 weeks (plus up to 90 days). Adhear Bone Conduction System: Non-invasive bone conduction hearing device using adhesive Bone anchored hearing aid (BAHA): Non-invasive bone conduction hearing device using a headband
18
BAHA Followed by Adhear (Aim 3) Group
Pediatric participants (aged 5-17 years) and their parents with conductive hearing loss or single-sided deafness who have not previously used a bone conduction device, will be provided with the BAHA system for 3 weeks (plus up to 90 days) followed by Adhear for another 3 weeks (plus up to 90 days). Adhear Bone Conduction System: Non-invasive bone conduction hearing device using adhesive Bone anchored hearing aid (BAHA): Non-invasive bone conduction hearing device using a headband
15
Pediatric Unilateral Conductive Hearing Loss (Aim 3a) Group
Pediatric participants (aged 2-17 years) and their parents with unilateral conductive hearing loss and are experienced bone conduction device users (6 months minimum of bone conduction device use) on a headband will be provided with the Adhear system for 2 weeks (plus up to 90 days). Adhear Bone Conduction System: Non-invasive bone conduction hearing device using adhesive
17
Pediatric Bilateral Conductive Hearing Loss (Aim 3b) Group
Pediatric participants (aged 2-17 years) and their parents with bilateral conductive hearing loss and are experienced bone conduction device users (6 months minimum of bone conduction device use) on a headband will be provided with the Adhear system. Participants who are fitted bilaterally will receive 2 Adhear systems (one for each ear) for 2 weeks (plus up to 90 days) at Visit 1. Participants who are fitted unilaterally will receive 1 Adhear system for 2 weeks (plus up to 90 days) at Visit 1, afterwards, will be fitted bilaterally at Visit 2 and receive the Adhear system for both ears for another 2 weeks (plus up to 90 days) for a total of 4 weeks (plus up to 180 days). Adhear Bone Conduction System: Non-invasive bone conduction hearing device using adhesive
4
Total66

Withdrawals & dropouts

PeriodReasonFG000FG001FG002FG003FG004FG005
Overall StudyLost to Follow-up010020
Overall StudyScreen Failure000200
Overall StudyWithdrawal by Subject100351

Baseline characteristics

CharacteristicSingle-Sided Deafness Adult (Aim1) GroupConductive Hearing Loss Adult (Aim 2) GroupAdhear Followed by BAHA (Aim 3) GroupBAHA Followed by Adhear (Aim 3) GroupPediatric Unilateral Conductive Hearing Loss (Aim 3a) GroupPediatric Bilateral Conductive Hearing Loss (Aim 3b) GroupTotal
Age, Categorical
<=18 years
0 Participants0 Participants9 Participants7 Participants8 Participants2 Participants26 Participants
Age, Categorical
>=65 years
1 Participants0 Participants0 Participants0 Participants0 Participants0 Participants1 Participants
Age, Categorical
Between 18 and 65 years
8 Participants3 Participants9 Participants8 Participants9 Participants2 Participants39 Participants
Ethnicity (NIH/OMB)
Hispanic or Latino
6 Participants1 Participants9 Participants9 Participants11 Participants3 Participants39 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
3 Participants1 Participants3 Participants1 Participants3 Participants1 Participants12 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants1 Participants6 Participants5 Participants3 Participants0 Participants15 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
2 Participants0 Participants0 Participants0 Participants1 Participants0 Participants3 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants1 Participants7 Participants5 Participants5 Participants0 Participants18 Participants
Race (NIH/OMB)
White
7 Participants2 Participants11 Participants10 Participants11 Participants4 Participants45 Participants
Sex: Female, Male
Female
6 Participants1 Participants11 Participants8 Participants12 Participants3 Participants41 Participants
Sex: Female, Male
Male
3 Participants2 Participants7 Participants7 Participants5 Participants1 Participants25 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
EG003
affected / at risk
EG004
affected / at risk
EG005
affected / at risk
deaths
Total, all-cause mortality
0 / 80 / 30 / 330 / 330 / 140 / 4
other
Total, other adverse events
0 / 80 / 30 / 330 / 330 / 140 / 4
serious
Total, serious adverse events
0 / 80 / 30 / 330 / 330 / 140 / 4

Outcome results

Primary

Aided Hearing Thresholds

Aided-hearing thresholds represent the softest sound that the participant can hear inside the audiometric test booth when using a hearing device. Aided hearing thresholds were measured using a traditional bone conduction device on a softband and the Adhear device in the test booth on day 14. Hearing thresholds were measured in hertz.

Time frame: Day 14 of the intervention

Population: This outcome measure corresponds to Aim 3, Aim 3a, and Aim 3b. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit. Insufficient sample collected for participants and thus the data could not be analyzed for arms BAHA Bilateral Conductive Hearing Loss Prior BAI Use and Adhear Bilateral Conducive Hearing Loss Prior BAI Use.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Hearing ThresholdsFrequency 100013.64 hertzStandard Deviation 7.47
BAHA ImplantAided Hearing ThresholdsFrequency 50015.64 hertzStandard Deviation 6.54
BAHA ImplantAided Hearing ThresholdsFrequency 25019.43 hertzStandard Deviation 6.44
BAHA ImplantAided Hearing ThresholdsFrequency 200018.86 hertzStandard Deviation 5.17
BAHA ImplantAided Hearing ThresholdsFrequency 300024.43 hertzStandard Deviation 6.85
BAHA ImplantAided Hearing ThresholdsFrequency 400026.50 hertzStandard Deviation 5.81
BAHA ImplantAided Hearing ThresholdsFrequency 600026.71 hertzStandard Deviation 5.3
BAHA ImplantAided Hearing ThresholdsFrequency 800030.43 hertzStandard Deviation 6.52
Adhear PreAided Hearing ThresholdsFrequency 200024.86 hertzStandard Deviation 6.71
Adhear PreAided Hearing ThresholdsFrequency 800037.5 hertzStandard Deviation 8.49
Adhear PreAided Hearing ThresholdsFrequency 25028 hertzStandard Deviation 9.76
Adhear PreAided Hearing ThresholdsFrequency 600037.64 hertzStandard Deviation 8.99
Adhear PreAided Hearing ThresholdsFrequency 400039.71 hertzStandard Deviation 8.48
Adhear PreAided Hearing ThresholdsFrequency 100021.43 hertzStandard Deviation 4.97
Adhear PreAided Hearing ThresholdsFrequency 50024.57 hertzStandard Deviation 7.51
Adhear PreAided Hearing ThresholdsFrequency 300034 hertzStandard Deviation 8.23
BAHA Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 50022.50 hertzStandard Deviation 5.24
BAHA Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 100022.50 hertzStandard Deviation 8.22
BAHA Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 200022.50 hertzStandard Deviation 4.18
BAHA Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 800038.33 hertzStandard Deviation 17.22
BAHA Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 300030 hertzStandard Deviation 6.32
BAHA Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 400030 hertzStandard Deviation 7.07
BAHA Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 600035 hertzStandard Deviation 10.48
BAHA Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 25024.17 hertzStandard Deviation 2.04
Adhear Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 600037 hertzStandard Deviation 10.37
Adhear Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 400032 hertzStandard Deviation 11.51
Adhear Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 300028 hertzStandard Deviation 12.54
Adhear Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 25024 hertzStandard Deviation 7.41
Adhear Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 100022 hertzStandard Deviation 6.71
Adhear Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 200027 hertzStandard Deviation 8.36
Adhear Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 800044 hertzStandard Deviation 12.94
Adhear Unilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 50021 hertzStandard Deviation 6.52
BAHA Bilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 800025 hertz
BAHA Bilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 25015 hertz
BAHA Bilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 300030 hertz
BAHA Bilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 400030 hertz
BAHA Bilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 600025 hertz
BAHA Bilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 50010 hertz
BAHA Bilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 100015 hertz
BAHA Bilateral Conductive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 200015 hertz
Adhear Bilateral Conducive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 800030 hertz
Adhear Bilateral Conducive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 300040 hertz
Adhear Bilateral Conducive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 100020 hertz
Adhear Bilateral Conducive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 200020 hertz
Adhear Bilateral Conducive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 400035 hertz
Adhear Bilateral Conducive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 50015 hertz
Adhear Bilateral Conducive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 600030 hertz
Adhear Bilateral Conducive Hearing Loss Prior BAI UseAided Hearing ThresholdsFrequency 25030 hertz
Primary

Aided Hearing Thresholds for Conductive Hearing Loss

Aided-hearing thresholds represent the softest sound that the participant can hear inside the audiometric test booth when using a hearing device. Aided hearing thresholds were measured using the participant's own device on their abutment and the Adhear device in the test booth on day 1. Hearing thresholds were measured in hertz.

Time frame: Day 1

Population: This outcome measure corresponds to Aim 2. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 25017.5 hertzStandard Deviation 3.54
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 50012.5 hertzStandard Deviation 10.61
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 100022.50 hertzStandard Deviation 3.54
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 200027.5 hertzStandard Deviation 3.54
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 300035 hertzStandard Deviation 0
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 400037.5 hertzStandard Deviation 10.61
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 600040 hertzStandard Deviation 14.14
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 800047.5 hertzStandard Deviation 3.54
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 800055 hertzStandard Deviation 7.07
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 25027.5 hertzStandard Deviation 3.54
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 300040 hertzStandard Deviation 7.07
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 50020 hertzStandard Deviation 0
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 600050 hertzStandard Deviation 7.07
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 100022.5 hertzStandard Deviation 3.54
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 400055 hertzStandard Deviation 7.07
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 200030 hertzStandard Deviation 7.07
Primary

Aided Hearing Thresholds for Conductive Hearing Loss

Aided-hearing thresholds represent the softest sound that the participant can hear inside the audiometric test booth when using a hearing device. Aided hearing thresholds were measured using the participant's own device on a softband and the Adhear device in the test booth on day 14. Hearing thresholds were measured in hertz.

Time frame: Day 14

Population: This outcome measure corresponds to Aim 2. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 300035 hertzStandard Deviation 0
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 25017.5 hertzStandard Deviation 3.54
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 400037.50 hertzStandard Deviation 10.61
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 100022.5 hertzStandard Deviation 3.54
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 600040 hertzStandard Deviation 14.14
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 50012.5 hertzStandard Deviation 10.61
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 800047.5 hertzStandard Deviation 3.54
BAHA ImplantAided Hearing Thresholds for Conductive Hearing LossFrequency 200027.5 hertzStandard Deviation 3.54
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 800057.5 hertzStandard Deviation 10.61
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 25022.5 hertzStandard Deviation 3.54
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 50025 hertzStandard Deviation 14.14
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 100017.5 hertzStandard Deviation 3.54
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 300047.5 hertzStandard Deviation 10.61
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 400055 hertzStandard Deviation 14.14
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 600050 hertzStandard Deviation 14.14
Adhear PreAided Hearing Thresholds for Conductive Hearing LossFrequency 200035 hertzStandard Deviation 14.14
Primary

Aided Hearing Thresholds for Single Sided Deafness

Aided-hearing thresholds represent the softest sound that the participant can hear inside the audiometric test booth when using a hearing device. Aided hearing thresholds were measured using the participant's own device on their abutment and the Adhear device in the test booth on day 1. Hearing thresholds were measured in hertz.

Time frame: Day 1

Population: This outcome measure corresponds to Aim 1. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 25036.25 hertzStandard Deviation 7.44
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 50028.13 hertzStandard Deviation 6.51
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 100020 hertzStandard Deviation 2.67
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 200023.13 hertzStandard Deviation 2.59
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 300027.5 hertzStandard Deviation 5.35
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 400033.13 hertzStandard Deviation 5.94
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 600031.88 hertzStandard Deviation 6.51
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 800040 hertzStandard Deviation 11.65
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 800056.88 hertzStandard Deviation 7.53
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 25035.63 hertzStandard Deviation 10.16
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 300044.38 hertzStandard Deviation 4.17
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 50037.50 hertzStandard Deviation 7.07
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 600056.88 hertzStandard Deviation 5.3
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 100030.63 hertzStandard Deviation 6.23
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 400051.25 hertzStandard Deviation 6.94
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 200035.00 hertzStandard Deviation 8.45
Primary

Aided Hearing Thresholds for Single Sided Deafness

Aided-hearing thresholds represent the softest sound that the participant can hear inside the audiometric test booth when using a hearing device. Aided hearing thresholds were measured using the participant's own device on a softband and the Adhear device in the test booth on day 14. Hearing thresholds were measured in hertz.

Time frame: Day 14

Population: This outcome measure corresponds to Aim 1. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 25037.5 hertzStandard Deviation 6.78
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 50031.75 hertzStandard Deviation 9.11
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 100024.38 hertzStandard Deviation 7.01
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 200028.88 hertzStandard Deviation 6.6
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 300035.38 hertzStandard Deviation 6.91
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 400045.25 hertzStandard Deviation 6.36
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 600046.5 hertzStandard Deviation 10.73
BAHA ImplantAided Hearing Thresholds for Single Sided DeafnessFrequency 800050.50 hertzStandard Deviation 6.37
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 800054.25 hertzStandard Deviation 7.21
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 25031.88 hertzStandard Deviation 11.27
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 300042.88 hertzStandard Deviation 4.82
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 50032.13 hertzStandard Deviation 9.63
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 600053.88 hertzStandard Deviation 7.51
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 100028.38 hertzStandard Deviation 4.98
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 400050.75 hertzStandard Deviation 7.8
Adhear PreAided Hearing Thresholds for Single Sided DeafnessFrequency 200031.75 hertzStandard Deviation 7.4
Secondary

Aided Speech in Noise Performance in Participants With Conductive Hearing Loss

Aided speech-in-noise performance is the ability to identify spoken words when background noise is present while using a hearing device. Aided speech-in-noise performance was measured using the participant's own device on their abutment and the Adhear device in the test booth on day 1. Aided speech-in-noise performance was measured in decibels.

Time frame: Day 1

Population: This outcome measure corresponds to Aim 2. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech front / Noise Front0.75 dBStandard Deviation 0.35
BAHA ImplantAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech poorer ear / Noise better ear-3 dBStandard Deviation 3.54
BAHA ImplantAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech better ear / noise poorer ear-6.5 dBStandard Deviation 0
Adhear PreAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech front / Noise Front-0.5 dBStandard Deviation 0.71
Adhear PreAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech poorer ear / Noise better ear-1.75 dBStandard Deviation 2.47
Adhear PreAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech better ear / noise poorer ear-6.5 dBStandard Deviation 1.41
Secondary

Aided Speech in Noise Performance in Participants With Conductive Hearing Loss

Aided speech-in-noise performance is the ability to identify spoken words when background noise is present while using a hearing device. Aided speech-in-noise performance was measured using the participant's own device on a softband and the Adhear device in the test booth on day 14. Aided speech-in-noise performance was measured in decibels.

Time frame: Day 14

Population: This outcome measure corresponds to Aim 2. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech better ear/noise poorer ear-7 dBStandard Deviation 0.71
BAHA ImplantAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech front/noise front-1.5 dBStandard Deviation 0.71
BAHA ImplantAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech poorer ear/noise better ear-0.5 dBStandard Deviation 3.54
Adhear PreAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech front/noise front-2.25 dBStandard Deviation 1.77
Adhear PreAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech poorer ear/noise better ear-1.5 dBStandard Deviation 2.83
Adhear PreAided Speech in Noise Performance in Participants With Conductive Hearing LossSpeech better ear/noise poorer ear-7.5 dBStandard Deviation 0
Secondary

Aided Speech-in-noise Performance in Participants With Single-sided Deafness

Aided speech-in-noise performance is the ability to identify spoken words when background noise is present while using a hearing device. Aided speech-in-noise performance was measured using the participant's own device on their abutment and the Adhear device in the test booth on day 1. Aided speech-in-noise performance was measured in decibels.

Time frame: Day 1

Population: This outcome measure corresponds to Aim 1. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Speech-in-noise Performance in Participants With Single-sided DeafnessSpeech front / Noise Front1.75 dBStandard Deviation 2.46
BAHA ImplantAided Speech-in-noise Performance in Participants With Single-sided DeafnessSpeech poorer ear / Noise better ear2 dBStandard Deviation 4.51
BAHA ImplantAided Speech-in-noise Performance in Participants With Single-sided DeafnessSpeech better ear / noise poorer ear-2.31 dBStandard Deviation 2.34
Adhear PreAided Speech-in-noise Performance in Participants With Single-sided DeafnessSpeech front / Noise Front1.81 dBStandard Deviation 2.25
Adhear PreAided Speech-in-noise Performance in Participants With Single-sided DeafnessSpeech poorer ear / Noise better ear5.75 dBStandard Deviation 3.87
Adhear PreAided Speech-in-noise Performance in Participants With Single-sided DeafnessSpeech better ear / noise poorer ear-4.31 dBStandard Deviation 1.83
Secondary

Aided Speech in Noise Performance in Participants With Single-sided Deafness

Aided speech-in-noise performance is the ability to identify spoken words when background noise is present while using a hearing device. Aided speech-in-noise performance was measured using the participant's own device on a softband and the Adhear device in the test booth on day 14. Aided speech-in-noise performance was measured in decibels.

Time frame: Day 14

Population: This outcome measure corresponds to Aim 1. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantAided Speech in Noise Performance in Participants With Single-sided DeafnessSpeech front/noise front0.5 dBStandard Deviation 1.98
BAHA ImplantAided Speech in Noise Performance in Participants With Single-sided DeafnessSpeech poorer ear/noise better ear3.81 dBStandard Deviation 3.54
BAHA ImplantAided Speech in Noise Performance in Participants With Single-sided DeafnessSpeech better ear/noise poorer ear-4.25 dBStandard Deviation 2.58
Adhear PreAided Speech in Noise Performance in Participants With Single-sided DeafnessSpeech front/noise front0.875 dBStandard Deviation 1.53
Adhear PreAided Speech in Noise Performance in Participants With Single-sided DeafnessSpeech poorer ear/noise better ear3.69 dBStandard Deviation 4.29
Adhear PreAided Speech in Noise Performance in Participants With Single-sided DeafnessSpeech better ear/noise poorer ear-4.19 dBStandard Deviation 2.55
Secondary

Participant Satisfaction With Adhear

Custom Subjective Device Questionnaire measured auditory, social emotional, and device satisfaction as a composite score using a Likert scale. Likert score range was 1-4. Higher scores denoted positive responses. The reported values represent an average across the multiple domains of the questionnaire.

Time frame: Day 14

Population: This outcome measure corresponds to Aims 1, 2, 3, 3a, and 3b. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantParticipant Satisfaction With AdhearSubject3.22 score on a scaleStandard Deviation 0.86
Adhear PreParticipant Satisfaction With AdhearSubject3.54 score on a scaleStandard Deviation 0.72
BAHA Unilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With AdhearSubject2.88 score on a scaleStandard Deviation 0.51
BAHA Unilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With AdhearParent2.99 score on a scaleStandard Deviation 0.57
Adhear Unilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With AdhearParent3.01 score on a scaleStandard Deviation 0.71
Adhear Unilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With AdhearSubject3.38 score on a scaleStandard Deviation 0.56
BAHA Bilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With AdhearParent3.24 score on a scaleStandard Deviation 0.94
BAHA Bilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With AdhearSubject3.33 score on a scaleStandard Deviation 1.2
Secondary

Participant Satisfaction With Adhear at Day 28 (Aim 3b)

Custom Subjective Device Questionnaire measured auditory, social emotional, and device satisfaction as a composite score using a Likert scale. Likert score range was 1-4. Higher scores denoted positive responses. The reported values represent an average across the multiple domains of the questionnaire.

Time frame: Day 28

Population: This outcome measure corresponds to Aim 3b.Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantParticipant Satisfaction With Adhear at Day 28 (Aim 3b)Subject2.87 score on a scaleStandard Deviation 0.48
BAHA ImplantParticipant Satisfaction With Adhear at Day 28 (Aim 3b)Parent2.94 score on a scaleStandard Deviation 0.49
Secondary

Participant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)

Custom Subjective Device Questionnaire measured auditory, social emotional, and device satisfaction as a composite score using a Likert scale. Likert score range was 1-4. Higher scores denoted positive responses. The reported values represent an average across the multiple domains of the questionnaire.

Time frame: Day 1

Population: This outcome measure corresponds to Aims 1, 2, 3, 3a, and 3b. Overall number of participants analyzed are those participants who received the intervention and/or completed up to the visit.

ArmMeasureGroupValue (MEAN)Dispersion
BAHA ImplantParticipant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Subject3.28 score on a scaleStandard Deviation 0.091
Adhear PreParticipant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Subject3.88 score on a scaleStandard Deviation 1.09
BAHA Unilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Subject2.43 score on a scaleStandard Deviation 0.52
BAHA Unilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Parent2.55 score on a scaleStandard Deviation 0.52
Adhear Unilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Parent2.71 score on a scaleStandard Deviation 0.51
Adhear Unilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Subject2.27 score on a scaleStandard Deviation 0.8
BAHA Bilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Parent3.03 score on a scaleStandard Deviation 0.59
BAHA Bilateral Conductive Hearing Loss Prior BAI UseParticipant Satisfaction With BAHA (Aims 1, 2, 3a and 3b) or No Device (Aim 3)Subject2.06 score on a scaleStandard Deviation 1.37

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026