Skip to content

A Pilot Study- Monitoring Cerebral Blood Flow in Neonates With Congenital Heart Defects

A Pilot Study- Monitoring Cerebral Blood Flow in Neonates With Congenital Heart Defects

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03512613
Enrollment
55
Registered
2018-05-01
Start date
2018-05-29
Completion date
2019-05-31
Last updated
2018-06-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cerebrovascular Circulation, Congenital Heart Defect

Brief summary

Congenital heart defects have an incidence of 9/1000 live births. Infants with congenital heart defects such as Transposition of Great Arteries / Hypoplastic Left Heart are at risk for brain injury because of concomitant brain malformations. Previous studies of cerebral MRI in infants with congenital heart defects showed that in 20-40% of cases there was preoperative brain injury and post operative with the same incidence. These findings are strongly associated with early and long-term neurodevelopmental injury. There is a necessity for a non invasive device who will monitor the cerebral blood flow during the hospitalization prior and post the cardiac defect repair surgery. The previous modal of the study device has been cleared for marketing by the FDA (k150268). The main goal of this study is to demonstrate that the new design of Ornim's c-FLOW 3310-P is easy to operate and effective in monitoring changes in cerebral blood flow in neonates as demonstrated in adults.

Detailed description

55 eligible neonates whom have been deemed as candidates for a cardiac surgery will be enroll to the study. At the first phase, 10 neonates will be monitored. After the investigator has assessed the patient as eligible for the study and consent will be received by the parents, the subject will be provided with a study enrollment number. All clinical assessments routinely preformed as per standard of care during all hospitalization, such as hemodynamic continues parameters, discreet samples will be documented in the medical records, and later on the requested assessments will be recorded in the designated Case Report Form. Monitoring will be performed a day prior to the repair surgery, following the surgery at the same day and one and two days after, for 3 hours per day. Additional standard of care parameters will be collected :Heart rate, Mean Arterial Blood Pressure, Saturation, Ventilator rate, Medications, Blood gases ( blood tests), Echocardiogram, pre-surgery Head US,. additional examination will be performed intended for the study: two post surgery Head US, S100B biomarker for brain injury and Neurological examinations prior and 7 days post- surgery( By standardized questionnaires). Sample size: 55: A sample size of 55 will enable to detect an increase of 20% in flow with a standard deviation of 50 assuming normal distribution a type 1 error of 5% and power of 80%. In order to evaluate the study design and data quality the sponsor will perform an interim analysis for the 10 first neonates. Quality assurance: Following the study initiation monitoring visit will be performed for the first patient. Additional visits will be performed according to recruitment rate. Source data verification and safety events follow up will be performed during those visits. Plan for missing data: Every effort will be made to complete follow-up for all subjects and avoid missing data, in particular regarding essential items. Statistical analysis: Descriptive statistics will be used to summarize results. Categorical measurements will be presented in contingency tables with counts & percent. Continuous measurements will be presented with N, means ±Standard Deviation, or median with 25th & 75th percentiles Minimum & Maximum. The percent of change in flow pre & post maneuver will be calculated using one sample t-test. Spearman correlation will be used to correlate the autoregulation index and neurological outcomes. Significance level will be defined as a=0.05. Statistical analyses will be carried out using SPSS (Statistical Package for the Social Sciences) 24.01 software.

Interventions

DEVICEc-FLOW 3310-P

c-FLOW 3310-P is a continuous, non-invasive monitor of cerebral deep tissue blood flow used to measure relative changes in blood flow. The device monitors regional micro circulatory blood flow in tissues, by using sensors placed near the area of interest.

Sponsors

Ornim Medical
Lead SponsorINDUSTRY

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
No minimum to 4 Weeks
Healthy volunteers
No

Inclusion criteria

1. Mutual parents' consent (outstanding exceptional cases who approved by the EC) 2. Born at gestational age of more than 34+6/7 weeks 3. Cardiac surgery between 0- 4 weeks of age 4. Head circumference \>= 31 cm

Exclusion criteria

1. Patient with implants located in the intended area of the c-FLOW 3310-P sensor location. 2. Laceration of scalp injury at the intended area of the c-FLOW 3310-P sensors 3. Known brain malformation 4. Hydrocephalus 5. Resuscitation between the time of surgery and neurological outcome assessment

Design outcomes

Primary

MeasureTime frameDescription
Change in c-Flow3310-P following routine maneuvers3 hours monitoring per day, for 4 daysChanges will be measured following routine maneuvers such as suction, leg lifting, Blood sample, changing position, feeding, presence of feeding tube etc. Change= (CFI(manipulation)- CFI(baseline))- CFI(baseline)

Secondary

MeasureTime frameDescription
The correlation between Auto-regulation index and Neurological outcomes3 hours monitoring per day, for 4 daysAuto regulation index (the correlation of Cerebral Flow Index& Mean Arterial Pressure) Neurological outcomes based on two validated questionnaires: PCPC (Pediatric Cerebral Performance Category) scale- ranging from 1-6 PSOM ( Pediatric Stroke Outcome Measure) scale - ranging from 1 to 10.

Countries

Israel

Contacts

Primary ContactOmer Bar Yosef, MD
Omer.BarYosef@sheba.health.gov.il+97252-6667344
Backup ContactOliana Vazhgovsky, BA
oliana.vazhgovsky@sheba.health.gov.il

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026