Validation of a PrCr Dipstick Diagnostic Test in Ghana

Validation of a Protein Creatinine (PrCr) Dipstick Diagnostic Test for Proteinuria Screening in Antenatal Care Clinics in Ghana

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03510286
Enrollment
1483
Registered
2018-04-27
Start date
2018-09-30
Completion date
2020-07-30
Last updated
2020-08-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Preeclampsia, Proteinuria

Keywords

proteinuria, preeclampsia, diagnostic, dipstick, protein, urine, creatinine

Brief summary

This evaluation will aim to generate a body of evidence that will determine performance characteristics of the current PrCr dipstick test and the feasibility of its use in target ANC settings. Data will be used to inform further product development and/or support development of an introduction framework, including the process and associated resources needed for incorporation of the PrCr test into future larger-scale demonstration studies as well as to support early product launch. The objectives of the evaluation are as follows: Primary objective: Assess the accuracy of the PrCr dipstick test for detection of proteinuria in representative antenatal care settings in Ghana. Exploratory objectives: * Understand the feasibility of integrating the use of the PrCr test into ANC services in Ghana. * Explore the potential for improved ANC management of PE/E using the PrCr test in intended ANC settings versus the current standard of care used for proteinuria screening, protein-only determination via a low -cost urine dipstick test.

Detailed description

This cross-sectional diagnostic accuracy evaluation will employ mixed methods to assess the performance of the PrCr dipstick test and to explore the operational feasibility of using this test as an alternative to the current protein-only test. These methods include: Assess the accuracy of the PrCr test for detection of proteinuria in a representative ANC setting in Ghana. • Detection of proteinuria using the PrCr dipstick test compared to the current standard of care and laboratory reference assay used for confirming proteinuria. Patient samples will be tested with multiple assays. The PrCr test and a protein-only dipstick (The Mission® Urinalysis Reagent Strips (Urine), will be used at the point of care. Patient samples will be transferred to KHRC laboratory using cold boxes (conditioned at 2oC - 8oC) and will be tested using a laboratory reference assay. Understand the feasibility of integrating the use of the PrCr test into ANC services. * Pre- and post-evaluation of ANC staff training on use of the PrCr test * Interviews with ANC staff * Consultations with key district and national stakeholders. Explore the potential for improved ANC management of PE/E using the PrCr test in the intended ANC setting. * Analysis of pregnancy outcomes (live or stillbirth) and review of referral records. Actual outcomes along with referral practices and linkage to care based on the current diagnostics will be compared to any potential changes in referral practices and linkage to care based on prospective PrCr test results. * Assessment of use of PrCr test with other clinical indicators and integration into diagnostic algorithms. Prospective PrCr test results will be integrated into an existing diagnostic algorithm to assess any potential changes in referral practices and linkage to care.

Interventions

DIAGNOSTIC_TESTTest-it™ PrCr Urinalysis Strips

The LifeAssay Diagnostics prototype PrCr dipstick has been designed to provide the measurement of both protein and creatinine while retaining a very low estimated cost that is comparable to the current protein-only dipsticks at $0.06-0.10 per test. In 2015, an initial laboratory-based validation study of the prototype LAD PrCr test was used on more than 500 characterized urine samples from pregnant women. This validation study demonstrated comparable accuracy for detection of severe proteinuria of the LAD PrCr test to the much more expensive commercial POC test available for PrCr determination, the Siemens Multistix® PRO 10LS. These results were compared to laboratory-based reference standard assays for proteinuria measurement.

Sponsors

Kintampo Health Research Centre, Ghana
CollaboratorOTHER
United States Agency for International Development (USAID)
CollaboratorFED
PATH
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Pregnant woman 18 years of age or older (self-report) * Attending a study site facility for ANC * ANC visit is within the final 12 weeks of pregnancy (within 12 weeks or less before expected due date) * Willing to provide written informed consent for study participation

Exclusion criteria

* ANC visit is not within the final 12 weeks of pregnancy * Unwilling to provide written informed consent for study participation * Pregnant woman less than 18 years of age

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of the PrCr dipstick test compared to a laboratory reference assay (chemistry analyzer measurement of protein and creatinine)September 20198-February 2019The results of the PrCr dipstick test will be compared to the results of a laboratory reference assay. Sensitivity and specificity analyses will be conducted at thresholds for normal and proteinuria.
Accuracy of the PrCr dipstick test compared to a protein only dipstick.September 20198-February 2019The results of the PrCr dipstick test will be compared to the results of the protein only test. Sensitivity and specificity analyses will be conducted at thresholds for normal and proteinuria.