Skip to content

Transthoracic Echocardiography of the Superior Vena Cava in Intensive Care Units (ICU) Intubated Patients

Transthoracic Echocardiographic Assessment of the Superior Vena Cava Flow Respiratory Variation in ICU Intubated Patients

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03508401
Acronym
CAVSUP
Enrollment
188
Registered
2018-04-25
Start date
2018-05-25
Completion date
2020-05-25
Last updated
2018-05-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Admission in Intensive Care Unit, Intubated Patients

Keywords

superior vena cava

Brief summary

Acute circulatory failure is frequent, affecting up to one-third of patients admitted to intensive care units (ICU). Monitoring hemodynamics and cardiac function is therefore a major concern. Analysis of respiratory diameter variations of the superior vena cava (SVC) is easily obtained with transesophageal echocardiography (TEE) and is helpful to assess fluid responsiveness. Transthoracic echocardiography (TTE) exploration of the SVC is not used in routine. Recently, micro-convex ultrasound transducers have been marketed and these may be of use for non-invasive SVC flow examination. However, analysis of diameter variations of the SVC with TTE does not seem to be possible since the approach from the supraclavicular fossa does not allow for a good visualization of the SVC walls. It was recently demonstrated in a short pilot study that TTE examination of the SVC flow with a micro-convex ultrasound transducer (GE 8C-RS) seems both easy to learn and to use (feasibility = 84.9%), and is reproducible in most ventilated ICU patients with an intraclass correlation coefficient for the systolic fraction of the superior vena cava flow of 0.90 (95% confidence interval \[0.86-0.93\]). The hypothesis is that cardio-respiratory interactions in intubated-ventilated patients are responsible of SVC flow variations and that the analysis of the SVC flow respiratory variations could be a new predictive tool of fluid responsiveness.

Interventions

OTHERPassive leg raising (PLR)

PLR is a test that predicts whether cardiac output will increase with volume expansion. By transferring a volume of around 300 mL of venous blood from the lower body toward the right heart, PLR mimics a fluid challenge. However, no fluid is infused and the hemodynamic effects are rapidly reversible, thereby avoiding the risks of fluid overload. PLR starts from the semi-recumbent and not the supine position. PLR is performed by adjusting the bed and not by manually raising the patient's legs

DEVICEEcho-Doppler measurements

Echo-Doppler measurements are performed with Vivid S6 model (GE Healthcare France, Lyon, France). All measurements are recorded at the end of expiration. Echo-Doppler measurements are performed in the upper part of the SVC, approximately 1 to 2 cm below the brachiocephalic vein. From this view, pulse Doppler is performed. Pulse Doppler waves obtained in the SVC are used to obtain velocity time integrals (VTI). Expiratory VTI is named VTImax and inspiratory VTI is named VTImin. These values will allow the calculation of Respiratory variations of the superior vena cava flow (ΔSVCf). ΔSVCf is calculated as (VTImax- VTImin )/(1/2(VTImax+ VTImin)).

Sponsors

Hospices Civils de Lyon
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients (≥ 18 years old) * Admission in ICU after tracheal intubation or tracheal intubation during the ICU stay * Volume-controlled ventilation with a tidal volume of 8 mL/kg * Patient or family agreement for the inclusion

Exclusion criteria

* Persistence of spontaneous breathing * Cardiac arrhythmia * Severe Acute Respiratory Distress Syndrome, defined as PaO2/FIO2 ratio \< 100 * Acute right ventricular failure defined by S'VD \< 10 cm or Tricuspid Annular Plane Systolic Excursion (TAPSE) \< 10 mm measured with Transthoracic Echocardiography (TTE)

Design outcomes

Primary

MeasureTime frameDescription
ventricular outflow tract velocity time index (LVOT TVI)The day of inclusionEcho-Doppler measurements are performed with Vivid S6 model (GE Healthcare France, Lyon, France). All measurements are recorded at the end of expiration. Echo-Doppler measurements are performed in the upper part of the SVC, approximately 1 to 2 cm below the brachiocephalic vein. From this view, pulse Doppler is performed. Pulse Doppler waves obtained in the SVC are used to obtain velocity time integrals (VTI). Expiratory VTI is named VTImax and inspiratory VTI is named VTImin. These values will allow the calculation of Respiratory variations of the superior vena cava flow (ΔSVCf). ΔSVCf is calculated as(VTImax- VTImin )/(1/2(VTImax+ VTImin))

Secondary

MeasureTime frame
optimal cut-off value of ΔSVCf to predict fluid-responsivenessThe day of inclusion
proportion of patients in which measurement of ΔSVCf is not possibleThe day of inclusion

Countries

France

Contacts

Primary ContactBertrand DEVIGNE, M.D, PhD
bertrand.devigne@chu-lyon.fr04.72.11.08.52
Backup ContactGuillaume MARCOTTE, M.D, PhD
guillaume.marcotte@chu-lyon.fr04.72.11.63.45

Outcome results

None listed