Using Pulse Counter Vigileo-Flotrac System in Transapical Off-pump Minimally Invasive Mitral Valve Repair

Hemodynamic Monitorization Using Pulse Counter Vigileo-Flotrac Cardiac Output System in Transapical Off-pump Minimally Invasive Mitral Valve Repair

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03506217
Enrollment
13
Registered
2018-04-24
Start date
2018-05-01
Completion date
2019-01-01
Last updated
2018-04-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mitral Valve Prolapse

Keywords

mitral valve prolaps,, chorda tendinea,, cardiac output

Brief summary

Minimally invasive transapical off-pump chordae implantation includes features such as tachycardia, arrhythmia, hemorrhage, sudden hemodynamic changes caused by the device moving in the left ventricle and the atrium, for anesthetists. In this observational study, the investigators presented the investigators's hemodynamic recuperation and anesthesia experiences revealed by cardiac output measurement after transapical mitral valve repair.

Detailed description

In Sakarya University Educational Research Hospital, perioperative file records of 13 patients who underwent mitral valve repair using the Neochord DS1000 system were retrospectively analyzed. In addition, hemodynamic measurements recorded with the Vigileo Flotrac invasive arterial cardiac output device were evaluated.

Interventions

DEVICEVigileo Flo-trac device

A Vigileo Flotrac pulse counter invasive arterial cardiac output meter was used for cardiac output measurement. Heart rate, blood pressure, cardiac output, stroke volume variance (SVV), systemic vascular resistance (SVR) values were recorded.

Sponsors

Sakarya University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

* All patients that surgical criteria for Neochord implantation with transapical mini-thoracotomy are prolapsus or chordae rupture in posterior, anterior areas or in both leaflets were included.

Exclusion criteria

*

Design outcomes

Primary

MeasureTime frameDescription
invasive arterial cardiac output (CO) measurement1 monthA Vigileo Flotrac pulse counter invasive arterial cardiac output meter was used for cardiac output measurement.
systemic vascular resistance (SVR)1mounthSystemic vascular resistance is used in calculations of blood pressure, blood flow, and cardiac function. Vasoconstriction (i.e., decrease in blood vessel diameter) increases SVR, whereas vasodilation (increase in diameter) decreases SVR
stroke volume variance (SVV)1 mounthStroke volume variation is a naturally occurring phenomenon in which the arterial pulse pressure falls during inspiration and rises during expiration due to changes in intra-thoracic pressure secondary to negative pressure ventilation (spontaneously breathing).
blood pressure1 mounthThe first (or top) number is your systolic blood pressure. It is the highest level your blood pressure reaches when your heart beats. The second (or bottom) number is your diastolic blood pressure. It is the lowest level your blood pressure reaches as your heart relaxes between beats.

Countries

Turkey (Türkiye)

Contacts

Primary ContactHavva Sayhan, Assis Prof
hsayhan@gmail.com+905056621021
Backup ContactUmit Karadeniz, prof
ukaradeniz2003@gmail.com+905326025264

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026