Skip to content

Transcatheter Leak Closure With Detachable Coils Following Incomplete Left Atrial Appendage Closure Procedures

Transcatheter Leak Closure With Detachable Coils Following Incomplete Left Atrial Appendage Closure Procedures

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03503253
Acronym
TREASURE
Enrollment
120
Registered
2018-04-19
Start date
2018-04-09
Completion date
2022-05-31
Last updated
2021-04-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Left Atrial Appendage Incomplete Closure

Brief summary

Although the clinical impact of left atrial appendage (LAA) leaks still requires confirmation, the open pouch with residual flow resulting from incomplete LAA closure may promote blood stagnation and thrombus formation, and increase the risk of thromboembolic events. The main purpose of this trial is to evaluate the safety and efficacy of percutaneous leak closure with detachable vascular coils.

Detailed description

Therapies locally targeting the LAA via occlusion, exclusion, or excision have emerged as an alternative and effective approach for stroke prophylaxis in AF patients, especially those with OAC contra-indications. Despite mounting evidence of their safety and efficacy in comparison with standard oral therapy, device-related thrombus and incomplete LAA closure resulting in residual, significant leak may occur, potentially hindering an effective stroke prevention. To date, detachable coils have found a wide range of applications for transcatheter occlusion/embolization procedures (e.g., cerebral aneurysms, pulmonary, renal and cerebral arteriovenous malformations, patent ductus arteriosus, endoleaks). The main purpose of this trial is to evaluate the feasibility and efficacy of transcatheter leak closure with detachable coils in patients with evidence of incomplete percutaneous/epicardial LAA exclusion.

Interventions

DEVICEInterlock-35 Fibered IDC Occlusion System

Use of detachable coil for LAA leak closure

DEVICEConcerto Helix Detachable Coil System

Use of detachable coil for LAA leak closure

DEVICEAzur Peripheral Coil System

Use of detachable coil for LAA leak closure

Sponsors

Texas Cardiac Arrhythmia Research Foundation
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Prospective, single arm study with consecutive, eligible subject enrollment. All subjects will undergo percutaneous LAA leak closure procedure with detachable coils.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age\> 18 years. * Presence of a significant LAA leak (moderate/severe following percutaneous occlusions or mild/severe after epicardial exclusions with the LARIAT suture delivery device). * Less moderate embolic risk (CHA2DS2-VASc ≥2) * High associated hemorrhagic risk (HASBLED ≥ 3), or absolute contraindication to OAC, or need for prolonged dual antiplatelet therapy, or history of thromboembolic events despite LAA occlusion/exclusion after other potential causes. * written informed consent obtained from subject or subject's legal representative and ability for subject to comply with the requirements of the study

Exclusion criteria

* Life expectancy \< 2 years. * pregnant, breastfeeding, or unwilling to practice birth control during participation in the study * presence of a condition or abnormality that in the opinion of the Investigator would compromise the safety of the patient or the quality of the data

Design outcomes

Primary

MeasureTime frameDescription
Procedural success7 daysProcedural success, defined as successful delivery, deployment release of detachable coil(s) into the LAA, and incidence of LAA occlusion as measured by fluoroscopy and echocardiographic color Doppler jets less than 3mm by TEE at the end of the procedure.
Rate of LAA leak closure60 daysLAA occlusion will be assessed by TEE color Doppler and will be defined as absence of flow in the LAA or minimal color Doppler jets (\< 1mm).
Incidence of Major Adverse Events (MAE)30 daysRate of procedure- and device-related complications (device embolization; cardiac injury, re-intervention, and/or device-related surgery; bleeding events such as pericardial effusion requiring drainage, cranial bleeding due to any source, gastrointestinal bleeding; transient ischemic attack/stroke; systemic embolism; death; or any other event related to the device or the procedure, which requires treatment).

Secondary

MeasureTime frameDescription
Composite of all-cause mortality, stroke and bleeding12 monthsComposite: stroke or transient ischemic attack, systemic embolism, major bleeding event.

Countries

United States

Contacts

Primary ContactAndrea Natale
andrea.natale@stdavids.com5127842651
Backup ContactDomenico G Della Rocca
domenico.dellarocca2@stdavids.com512-544-8198

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 28, 2026