Skip to content

French Version of the Orofacial Esthetic Scale

Development and Validation of the French Version of the Orofacial Esthetic Scale: OES-F

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03499093
Enrollment
140
Registered
2018-04-17
Start date
2016-09-26
Completion date
2018-01-10
Last updated
2018-04-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Esthetics, Dental

Keywords

esthetics, orofacial esthetic scale

Brief summary

The aims of this study were to develop a French version of the Orofacial Esthetic Scale (OES-F) and to investigate its psychometric properties. The OES is an eight-item instrument that assesses self-reported orofacial esthetics in prosthodontic patients. The first seven items refer to direct esthetic impacts and the eight is a global assessment item. For each item, an 11-point numeric scale (ranged from 0 = very dissatisfied to 10 = very satisfied) is used, and the first seven scores are combined into a summary score from 0 (worst score) to 70 (best score). The original English version of the OES was translated into French according to the guidelines. The reliability (internal consistency and test-retest reliability) and validity (convergent and discriminative validities) were tested in a sample of 140 patients. To assess test-retest reliability, 35 patients answered twice the OES-F with a temporal distance of two weeks apart.

Detailed description

Participants From September 2016 to december 2017, 160 patients aged over 18 have been recruited at the university dental clinic of the Rothschild Hospital, Paris, among patients pending dental treatment. Inclusion criteria were : literate French speakers, willing and able to complete the survey in a single setting. Patients suffering from head and neck tumors, defects after tumor resection, radiotherapy treatment, patients suffering from dementia or cognitive impairment, and communication difficulties were excluded. The pilot version was tested in a sample of twenty patients who were not involved in the main study. One hundred forty patients answered the final French version of the questionnaire to assess the psychometric properties of the OES-F. They were first divided into two groups according to their prosthetic needs. Participants were further allocated to two groups according to their esthetical concerns. Finally, the french version of the OES was tested with n=35 prothetic patients with esthetic expectations (PP-E), with n=35 prothetic patients without esthetic expectations (PP-NE), with n=35 subjects with esthetic concerns (C-E) and n=35 subjects without any esthetic concern (C-NE). Prosthetic patients were recruited either during the initial visit or before prosthetic treatment. Control subjects were recruited either during their initial visit or a follow-up consultation. All subjects provided written informed consent before inclusion and had their anonymity respected throughout the course of the study. The study was approved by the Ethics Committee of research projects of the Robert Debré Hospital (n° 2016/303(2). In application of the french law of January 6, 1978 relative to information technology, the study has been declared to the national data protection agency under the number 1977961v0. Development of the french OES version The traduction and cross-cultural adaptation was performed according to the guidelines. Briefly, the english version was first translated into french by two dental practitioners and then back translated in english by two native english speakers. Both translated versions were discussed by the research team and appropriate changes were formulated to the french version if necessary to clarify any item of the questionnaire. Clear understanding of any question and the entire french version of the questionnaire was tested with twenty participants. Minor changes concerned only formulation of general presentation of the questionnaire. The psychometric validity of the final french version was finally tested, including reliability and validity.

Interventions

OTHEROES

The first seven items of OES refer to face, facial profile, mouth, teeth alignment, teeth form, teeth color and gums. They are combined into an OES summary score ranging from 0 to 70. The eight item of OES is an overall impression item and is not included in the summary score. Internal Consistency was determined using Cronbach's alpha and inter-item correlation for the OES scores (n=140). Test-Retest Reliability was assessed using Intraclass Correlation Coefficient. Patients with prosthetic needs (n=20 PP-E subjects and n=15 PP-NE subjects) completed twice the OES-F at an interval of two weeks. Convergent validity was assessed by comparing mean OES summary scores evaluated by participant of the esthetic group (PP-E, n=35) and by an expert group. Expert OES score were based on three photographs of each participant. Discriminative validity was tested by comparing the OES summary scores using a one-way ANOVA and Scheffe post hoc test.

Sponsors

Hôpital Rothschild
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* literate French speakers, willing and able to complete the survey

Exclusion criteria

* Patients suffering from head and neck tumors, defects after tumor resection, radiotherapy treatment, patients suffering from dementia or cognitive impairment, and communication difficulties

Design outcomes

Primary

MeasureTime frameDescription
Change from baseline orofacial esthetic scale (OES) summary score at two weeksevaluated at date of inclusion and two weeks laterThe first seven items refer to esthetic components: face, facial profile, mouth (smile, lips, and visible teeth), teeth alignment, teeth form, teeth color and gums. These seven scores are combined into an OES summary score ranging from 0 (worst score, patient is very dissatisfied with all esthetics items) to 70 (best score, patient is very satisfied with all esthetics items).

Secondary

MeasureTime frameDescription
Change from baseline overall impression (eight item of OES questionnaire) at two weeksevaluated at date of inclusion and two weeks laterThe eight item is an overall impression item and is not included in the summary score.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026