Skip to content

Fujifilm DBT Plus S-View Versus FFDM Alone in the Detection of Breast Cancer

A Multi-Reader Multi-Case Controlled Clinical Trial to Evaluate the Comparative Accuracy of the Fujifilm DBT Plus S-View Versus FFDM Alone in the Detection of Breast Cancer - A Pilot Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03491917
Enrollment
100
Registered
2018-04-09
Start date
2017-11-03
Completion date
2018-02-15
Last updated
2020-06-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast Cancer

Brief summary

The purpose of this pilot is to provide credible performance estimate information in order to conduct a subsequent pivotal reader study.

Detailed description

This clinical research is a retrospective, pilot, multi-reader, multi-case (MRMC) study with an enriched sample of 100 breast screening or diagnostic cases which were selected from the library of mammograms collected under Fujifilm protocol FMSU2013-004A (all subjects previously provided written informed consent agreeing their image data and supporting documentation could be used for future research and investigations). Approximately 6 qualified radiologists will independently perform two reads on all (approximately 100) cases. Each reader will read each case both as a FFDM (Full Field Digital Mammography) read, and a DBT (Digital Breast Tomosynthesis) plus S-View (Synthesized View) read on the ASPIRE Bellus II workstation.

Interventions

DBT plus S-View images

FFDM alone images

Sponsors

Fujifilm Medical Systems USA, Inc.
Lead SponsorINDUSTRY

Study design

Observational model
CASE_CROSSOVER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Female subjects participating in FMSU2013-004A protocol with known clinical status

Exclusion criteria

* Female subjects that did not have known clinical status in FMSU2013-004A

Design outcomes

Primary

MeasureTime frameDescription
Compare Per Subject Average Area Under the ROC (Receiver Operating Characteristic) Curve (AUC)2 visits with 4 week washout periodCompare per subject average area under the ROC curve (AUC) for DBT (Digital Breast Tomosynthesis) plus S-View (Synthesized View) versus FFDM (Full Field Digital Mammography), based on per-subject POM (probability of malignancy) scores and requiring correct lesion localization. The primary endpoint was non-inferior per-subject average AUC. Statistician estimated AUCs for each reader in each review condition (FFDM, DBT plus S-View) based on per-subject POM scores requiring correct lesion localization. Statistician also calculated for each reader the non-parametric (trapezoidal) AUC for the FFDM read, the DBT plus S-View read, and the difference between them. These AUC's, differences between them, and the associated variance-covariance matrix were obtained using the method of DeLong, et al.

Countries

United States

Participant flow

Pre-assignment details

This was a retrospective, multi-reader multi-case reader study. Six (6) radiologist readers read all 100 cases (half FFDM and half DBT plus S-View reads) at each of 2 visits which were separated by a memory washout period of approximately 4 weeks. Images were previously acquired under Fujifilm protocol FMSU2013-004A.

Participants by arm

ArmCount
DBT Plus S-View and FFDM Alone
Readers will read half of the DBT plus S-View images followed by half of the FFDM only images at each of 2 sessions. There was a four week memory washout period between the 2 sessions.
100
Total100

Baseline characteristics

CharacteristicDBT Plus S-View and FFDM Alone
Age, Continuous58 years
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
2 Participants
Race (NIH/OMB)
Black or African American
6 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
1 Participants
Race (NIH/OMB)
White
91 Participants
Region of Enrollment
United States
100 participants
Sex: Female, Male
Female
100 Participants
Sex: Female, Male
Male
0 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 1000 / 100
other
Total, other adverse events
0 / 1000 / 100
serious
Total, serious adverse events
0 / 1000 / 100

Outcome results

Primary

Compare Per Subject Average Area Under the ROC (Receiver Operating Characteristic) Curve (AUC)

Compare per subject average area under the ROC curve (AUC) for DBT (Digital Breast Tomosynthesis) plus S-View (Synthesized View) versus FFDM (Full Field Digital Mammography), based on per-subject POM (probability of malignancy) scores and requiring correct lesion localization. The primary endpoint was non-inferior per-subject average AUC. Statistician estimated AUCs for each reader in each review condition (FFDM, DBT plus S-View) based on per-subject POM scores requiring correct lesion localization. Statistician also calculated for each reader the non-parametric (trapezoidal) AUC for the FFDM read, the DBT plus S-View read, and the difference between them. These AUC's, differences between them, and the associated variance-covariance matrix were obtained using the method of DeLong, et al.

Time frame: 2 visits with 4 week washout period

Population: Retrospective images used from Fujifilm protocol FMSU2013-004A. All readers read the same 100 images in their own randomized order during 2 sessions (they read half of each modality at each session which were separated by a 4 week washout period).

ArmMeasureValue (MEAN)
DBT Plus S-ViewCompare Per Subject Average Area Under the ROC (Receiver Operating Characteristic) Curve (AUC)0.819 Probability
FFDM AloneCompare Per Subject Average Area Under the ROC (Receiver Operating Characteristic) Curve (AUC)0.796 Probability
Comparison: The primary endpoint for this study was a non-inferior per-subject average area under the receiver operating characteristic (ROC) curve (AUC) requiring correct lesion localization for DBT (digital breast tomosynthesis) plus S-View (synthesized view) versus FFDM (full field digital mammography). AUCs for each reader were estimated in each review condition based on per-subject probability of malignancy (POM) scores requiring correct lesion localization.p-value: <0.01t-test, 2 sided

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026