Skip to content

Comparison of Two Radial Artery Segments Related to Old-Fashioned Radial and New Snuff Box Vessel Approach by US

Comparison of Two Radial Artery Segments Related to Old-Fashioned Radial and New Snuff Box Vessel Approach. Ultrasound Study of Both Arms

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03486470
Enrollment
520
Registered
2018-04-03
Start date
2018-04-15
Completion date
2018-08-15
Last updated
2018-04-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Diseases

Brief summary

The purpose of this study is to determine if there is a difference in the size and the depth of the radial artery at the access points for established radial and new distal radial approach for the arteries of both arms

Detailed description

Radial approach for coronary and peripheral procedures is now well established due to both patient and operator preference and carries a lower risk of bleeding and mortality. The most lasting consequence of transradial procedures remains radial artery occlusion, which is mainly influenced by the artery diameter and the size of the sheath. As a new, more distal approach looms on the horizon, it is plausible to determine factors that could impact its feasibility. Since the success rate for artery cannulation depends to a great extent on the size and the depth of the artery, the current study examines both parameters, as well as whether they are influenced by variables such as sex, body mass index, handedness, or comorbidities i.e. diabetes mellitus and hypertension.

Interventions

DIAGNOSTIC_TESTUltrasound examination of radial arteries

Measuring the diameter and the depth of two radial segments on both arms

Sponsors

Dr. Stephan Cherkezov Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients \>18 years old admitted to the Cardiology Department

Exclusion criteria

* Previous transradial procedures * Arm AV fistula for dialysis access * History of upper limb peripheral arterial disease * Hemiparesis * Hemodynamic instability

Design outcomes

Primary

MeasureTime frameDescription
Comparison of ultrasound derived diameters of radial artery measured at sites related to two different transradial arterial approaches for catheterization1 dayMeasuring diameters of the radial artery at the access points for well established radial and new distal radial approach and finding or not a significant difference could have some implications for choosing the access radial site. At the end of a routine echocardiographic evaluation, four short axis measurements (one proximal and one distal on each arm) of the radial artery diameters will be done with a vascular probe.

Secondary

MeasureTime frameDescription
Comparison of ultrasound derived depth of radial artery measured at sites related to two different transradial arterial approaches for catheterization1 dayAt the end of a routine echocardiographic evaluation, four measurements (one proximal and one distal on each arm) of the radial artery depth will be done with a vascular probe in a neutral position of the hand.
Impact of sex, BMI, hand-dominance or comorbidities on the size and the depth of the arterial segments1 dayTo determine if sex, BMI, hand-dominance and widespread comorbidities (hypertension and diabetes mellitus) influence the size and the depth of the radial artery

Contacts

Primary ContactValentin Krastev, MD
vgkrastev@abv.bg+359887868407
Backup ContactHaralamby Benov, MD
hobenov@yahoo.com

Outcome results

None listed