Ideal Point of Transluminal Light in Tracheal Intubation With a Light Wand

Ideal Point of Transluminal Light in Tracheal Intubation With a Light Wand

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03480035
Enrollment
107
Registered
2018-03-27
Start date
2018-03-06
Completion date
2018-07-27
Last updated
2018-12-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Neck Disease, Tooth Abnormalities, Trismus

Brief summary

If the patients's teeth are weak or the mouth dose not open well, the lightwand is a useful device when endotracheal intubation is necessary. Therefore, if the appropriate position of the light beam is determined and the distance of the light source suitable for intubation using the lightwand is obtained from anatomical structures such as thyroid cartilage and cricoid cartilage, it is clinically useful. Because it can prevent unnecessary deep insertion or shallow insertion that can cause damage to anatomical structures during intubation.

Detailed description

Studies have been reported on the proper position to bend the lightwand and the appropriate angle to bend when performing endotracheal intubation with lightwand. For ease of procedure, the assistant has to lift the patient's lower jaw or perform a neck extension. However, there is no report on the position of the lightbulb when the light passes through the front of the airway and neck and appears bright in the midpoint. The prodcedure is as follows. 1. FOB examination and check position of light below 1cm from vocal cord 2. lightwand intubation aimed at checkpoint 3. measurement of distance from thyroid cartilage/cricoid cartilage to light point

Interventions

intubation using lightwand

Sponsors

Keimyung University Dongsan Medical Center
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* impossibility of neck extension * trismus * weak teeth

Exclusion criteria

* previous history of larynx or neck surgery * no informed consent

Design outcomes

Primary

MeasureTime frameDescription
distance from lightbeam of the FOB to thyroid cartilagebefore intubationwe will measure straight distance from lightbeam of the FOB to thyroid cartilage on the surface of patient's neck
distance from lightbeam of the FOB to cricoid cartilagebefore intubationwe will measure straight distance from lightbeam of the FOB to cricoid cartilage on the surface of patient's neck

Secondary

MeasureTime frameDescription
distance from lightbeam of the FOB to sternal notchbefore intubationwe will measure straight distance from lightbeam of the FOB to sternal notch on the surface of patient's neck