Performance and Efficacy of the CardiacSense1 for Detection of Atrial Fibrillation

A Prospective, Open, Multi-Center, Controlled Study to Evaluate the Safety, Performance and Efficacy of the CardiacSense1 for Detection of Atrial Fibrillation

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03477734
Enrollment
53
Registered
2018-03-26
Start date
2019-02-20
Completion date
2020-06-09
Last updated
2020-07-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrium; Fibrillation

Brief summary

A Prospective, Open, Multi-Center, Controlled Study to Evaluate the Safety, Performance and Efficacy of the CardiacSense1 for Detection of Atrial Fibrillation. The clinical study is intended to establish the efficacy and safety of the CardiacSense1 wearable device intended to monitor and detect heart arrhythmia, specifically atrial fibrillation (A-Fib) based on a comparison to a control device, which is an off-the-shelf cleared Holter ECG device

Detailed description

The clinical study is intended to establish the efficacy and safety of the CardiacSense1 wearable device intended to monitor and detect heart arrhythmia, specifically atrial fibrillation (A-Fib). Study design as as follows: 100 subjects, 50 (at least 30% of each gender) with A-fib and 50 without (at least 30% of each gender). All subjects will be measured during at least 24 hours. Primary endpoint - A-Fib detection Control: Holter device will be the reference For PPG analysis, each one hour will be considered as an event: If A-Fib is present for more than accumulated 5 minutes in that specific hour then it shall be considered an A-Fib hour If A-fib was present for less than accumulated 5 minutes then it shall be considered a Non-A-Fib hour. For ECG analysis, each measurement of between 1-3 minutes will be considered an event. If A-Fib is present at that specific measurement, then it shall be considered an A-Fib event If A-fib was not present at that specific measurement, then it shall be considered a Non-A-Fib hour. Sensitivity (true positive) is defined as the percentage of Holter defined A-fib hours/A-Fib event found by PPG/ECG. The asked sensitivity is 90%. Specificity (true negative) is defined as the percentage of Holter defined Non-A-fib hours/A-Fib event found by PPG/ECG. The required specificity is 90%.

Interventions

DEVICECS1 & heart monitor

Daily activities while wearing the investigational device as well as the control device

Sponsors

CardiacSense Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SCREENING
Masking
NONE

Intervention model description

Males and females, 50 of them diagnosed with atrial fibrillation (AF), and 50 healthy participants, at least 30% of each gender in each group.

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
Yes

Inclusion criteria

* Age of eighteen (18) year and above * Diagnosed with atrial fibrilation (Permanent of persistent), or healthy participants able to and willing to sign the informed consent form For control group-no known cardiac problems

Exclusion criteria

* Subjects who are currently enrolled in another clinical investigation in which the intervention might compromise the safety of the subject's participation in this study. * Subjects with low perfusion as indicated by the watch * Women who are pregnant or breastfeeding

Design outcomes

Primary

MeasureTime frameDescription
CardicacSense1 atrial fibrillation detection rate24 to 48 hoursComparison of the number of atrial fibrillation sessions detected by reference comparing to PPG and ECG sensors in CardiacSense device.
Safety of CardicacSense124 to 48 hoursIncidence and severity of device related Adverse Events

Secondary

MeasureTime frameDescription
Usability24 to 48 hoursEase of use of the CardiacSense1 device based on user questionnaire

Countries

Israel

Outcome results

None listed