Skip to content

Anesthetic Cost Analysis With Desflurane in Automated Gas Control Mode

Anesthetic Cost Analysis With Desflurane in Automated Gas Control Mode With Maquet Flow-i Anaesthesia Machine

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03465475
Enrollment
60
Registered
2018-03-14
Start date
2018-07-01
Completion date
2021-03-01
Last updated
2021-08-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Safety Issues

Keywords

Low flow anesthesia, Desflurane, Cost analysis, Automated gas control

Brief summary

Inhalation agents constitute the major part of anesthetic drug costs (20% - 25%) and a significant portion of the applied inhalation agents are thrown into the atmosphere through the waste gas system without being absorbed by the patient. The amount of waste gas is directly correlated to the fresh gas flow (FGF). Reducing the TGA during general anesthesia reduces the consumption of inhalant agents and contributes to the reduction of greenhouse gas pollution. Risks such as hypoxia, hypercapnia, inadequate depth of anesthesia and potential toxic gas accumulation were associated with low flow anesthesia, but the patient was provided with adequate safety by following pulse oximetry, capnography, FiO2 and anesthetic gas analysis. We aimed to perform anesthetic cost analysis and patient security in automated gas control mode (AGC).

Detailed description

After the ethical approvel 60 adult patients scheduled for hepatectomy will be taken to study. Patients will be monitored after they are taken to the operating room (ECG, NIBP, SpO2, Body Temp, BIS, NIRS, PVI, PI, ORI). After the anesthesia induction and tarakeal entubation, first twenty patient will take 300 mL fresh gas flow with AGC mode (group 1), Second twenty patient will take 600 mL fresh gas flow with AGC mode (group 2), third twenty patient will take 600 mL fresh gas flow with manually. Hemodynamic and gas consumption data will be recorded. An operating room will be reserved for this study.

Interventions

None listed

Sponsors

Inonu University
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

* Adult patients undergoing hepatectomy with general anesthesia

Exclusion criteria

* Essential data missing * Patient participating in other research projects * Drug allergy * Anesthetic complication story

Design outcomes

Primary

MeasureTime frameDescription
Amount of used anesthetic gas (desflurane)Through study completion, an average of 2 monthAmount of used desflurane will be determined in milliliter by anesthesia machine (Maquet Flow i40) for each patient.

Secondary

MeasureTime frameDescription
Heart rateThrough study completion, an average of 2 monthHeart rate/min
Mean arterial pressureThrough study completion, an average of 2 monthMean arterial pressure (mm/Hg)
Peripheral oxygen saturationThrough study completion, an average of 2 monthPeripheral oxygen saturation (%)

Countries

Turkey (Türkiye)

Outcome results

None listed