Fluid Responsiveness Evaluation in Patients With Acute Circulatory Failure and Arrhythmia With Atrial Fibrillation: Indice Delta ITV / Delta RR

Fluid Responsiveness Evaluation in Patients With Acute Circulatory Failure and Arrhythmia With Atrial Fibrillation: Indice Delta ITV / Delta RR

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03461094
Enrollment
7
Registered
2018-03-09
Start date
2017-05-17
Completion date
2020-06-12
Last updated
2020-06-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Arrhythmia Atrial

Brief summary

Fluid therapy is often used as first line treatment of acute circulatory failure, aiming an increase in cardiac output (by improving preload) and in tissue perfusion. Depending on left ventricular systolic function, fluid challenge could lead to an increase in cardiac ouput and tissue perfusion, or only detrimental consequences (by fluid overload and aggravation of lung and tissues oedema, increase of morbi-mortality). Patients are defined as responders to fluid therapy if one can observe an increase of cardiac output up to 15% after fluid therapy (500ml of crystalloids): gold standard test used in most of the studies on the subject. Literature reports on heterogenous populations a reproductible and constant response rate to this fluid challenge of 50%. It seems reasonable to dispose of indices allowing to predict fluid responsiveness without resulting in fluid intake. Statics markers have been abandonned for several years and dynamics methods have been developped. In front of arrythmia, validated methods are scarce. Passive leg rising method appears to be the only one and it's validity seems to be less well documented than in sinusal patients. The purpose of this study is to determine a new method to assess fluid responsiveness in arrythmic patients. In atrial fibrillation, RR interval varies widely between cardiac cylces. Systolic interval remain constant. Variations will occure at expense of diastolic interval, or ventricular filling interval. One can reliably assume that when RR is longer, preload is rising. If the patient is on the ascendant part of the Franck-Starling curve, a longer RR should cause au greater VTI (Vitess Time Integral, surrogate of cardiac output). The evaluation by transthoracic echocardiography of the indice delta ITV / delta RR should determine the degree of fluid responsiveness in arrhythmic patients. After decision of fluid expansion, patients will have haemodynamic and echocardiographic data measured, delta ITV / delta RR indice assessed, then passive leg rising and fluid expansion with 500 ml of cristalloids administered, with evaluation of VTI (as surrogate of cardiac output) at each time. Fluid responders will be compared to non-responders to evaluate the diagnostic performances of the indice delta ITV / delta RR.

Interventions

DEVICEPreload assessment and volume expansion

Fluid therapy perform

Sponsors

Poitiers University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Hospitalized patients in the units of Surgical ICU and Cardiothoracic ICU of the Universatory Hospital of Poitiers * With atrial Fibrillation * With spontaneous ventilation * With acute circulatory failure and medical decision to fluid therapy (Systolic Arterial Blood Pressure \< 90 mmHg and/or vasopressors agents) * With no left or right ventricular dysfunction

Exclusion criteria

* Patients \< 18 yrs * Contraindictions to passive leg rising * Clinical evidence of hemorrhagic shock * Cardiogenic shock * Necessity of fluid expansion in emergency * No echographic windows

Design outcomes

Primary

MeasureTime frameDescription
Evaluation of the diagnostic performance of the index deltaI ITV / delta RRFluid therapy taking 20 minutes, with responsiveness evaluation within the 5 minutes following fluid therapyIncrease of 15% or more of stroke volume after fluid therapy

Secondary

MeasureTime frame
Diagnostic performances of passive leg rising for prediction of fluid responsivenessFluid therapy taking 20 minutes, with responsiveness evaluation within the 5 minutes following fluid therapy
Diagnostic performances of respiratory variations of inferior vena cava for prediction of fluid responsivenessFluid therapy taking 20 minutes, with responsiveness evaluation within the 5 minutes following fluid therapy