Skip to content

Comparison of AMR and ADR Between Endocuff Vision-assisted and Conventional Colonoscopy: a Multicenter Randomized Trial

Comparison of Adenoma Miss Rate and Adenoma Detection Rate Between Endocuff Vision®-Assisted Colonoscopy and Conventional Colonoscopy: a Multicenter Randomized Trial

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03418948
Acronym
EXCEED
Enrollment
708
Registered
2018-02-01
Start date
2017-12-08
Completion date
2019-11-01
Last updated
2018-02-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Colorectal Neoplasms

Brief summary

The aim of this international multicenter study is to compare the adenoma detection rate and adenoma miss rate of conventional and Endocuff Vision-assisted colonoscopy.

Detailed description

Rationale: Population screening programs for colorectal cancers (CRC) are increasingly adapted as a public health initiative with the primary goal to prevent CRC and CRC related deaths. \[2-4\] The ultimate benefit of CRC screening relies on the detection and resection of (pre-)malignant colon lesions, and for this colonoscopy is the preferred modality. Recently, concerns have been raised about the effectiveness of colonoscopy in the prevention of CRC after several studies reported unexpected high incidence rates of interval carcinomas (IC), especially in the proximal colon.\[5-9\] Most ICs are suspected to arise from missed colon lesions during colonoscopy. The retrograde approach of colonic inspections may contribute to colon lesions remaining undetected as it limits visualization of the proximal sides of haustral folds and flexures. Endocuff Vision® is a single-use, disposable medical device designed to improve the detection of colon lesions. The 'finger-like' projections of the device provide fold retraction allowing the visualization of otherwise hidden anatomical areas. Additionally, Endocuff Vision® may improve scope tip stability and prevent scope slippage. Objectives: 1. To compare adenoma miss rates (AMR) between Endocuff Vision®-assisted colonoscopy (EAC) and conventional colonoscopy (CC) 2. To compare adenoma detection rates (ADR) between EAC and CC 3. To assess whether a proposed increased ADR and reduced AMR with EAC is indeed due to the fold-flattening device or merely a consequence of the second colonoscopy procedure performed. 4. To assess the clinical relevance of the polyps missed during the first colonoscopy procedure. Study design: This multicenter, randomized, same-day, back-to-back tandem colonoscopy trial will include four separate study groups: group A; CC followed by CC, Group B; CC followed by EAC, Group C; EAC followed by CC, and group D; EAC followed by EAC. Study population: Patients between the ages of 40 and 75-years referred for screening (non-IFOBT based), diagnostic or surveillance colonoscopy. Main study parameters/endpoints: The primary endpoint of the study will be AMR. Secondary endpoints include; ADR, mean number of adenomas detected per colonoscopy procedure, number of sessile serrated polyps, the total number of colon lesions found during the first and second examination (which will be compared for size, colon distribution, morphologic and histopathological characteristics), cecal intubation rates, bowel cleansing levels, procedure times, sedation use, (severe) adverse events, patient reported outcome (pain) and post-colonoscopy surveillance intervals applying European and United states surveillance guidelines.

Interventions

DEVICECC followed by EC

CC = conventional colonoscopy EC = endocuff assisted colonoscopy

DEVICEEC followed by CC

CC = conventional colonoscopy EC = endocuff assisted colonoscopy

DEVICE2x EC

EC = endocuff assisted colonoscopy

DEVICE2x CC

CC = conventional colonoscopy

Sponsors

Norgine
CollaboratorINDUSTRY
Radboud University Medical Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
DIAGNOSTIC
Masking
DOUBLE (Subject, Investigator)

Masking description

Participants will be blinded for the allocation. Physicians can not be blinded for the use of Endocuff, but during the first procedure they will be blinded for the second procedure method to limit observer related bias.

Eligibility

Sex/Gender
ALL
Age
40 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* Patients, aged between 40 and 75-years old, referred and scheduled for either screening (non-FIT/gFOBT based), diagnostic or surveillance colonoscopy.

Exclusion criteria

* Prior surgical resection of any portion of the colon or a history of radiotherapy for any abdominal or pelvic disease. * Personal history of colon cancer or polyposis syndrome. * Familial adenomatous polyposis (FAP) * Known colitis or suspicion of colitis (ulcerative colitis, Crohn's colitis, diverticulitis, infective colitis). * Lower gastro-intestinal bleeding requiring acute intervention. * Suspicion of large bowel obstruction or toxic megacolon. * Prior incomplete colonoscopy (not including insufficient preparation). * Patients referred for a therapeutic procedure or assessment of a known non-resected lesion. * Not sufficiently corrected anticoagulation disorders * Poor general condition (\>3 American Society of Anesthesiologist) * Overweight (\>120 kg) * Inability to provide informed consent.

Design outcomes

Primary

MeasureTime frameDescription
Adenoma miss rate (%)18 monthsTo compare adenoma miss rates (AMR) between Endocuff Vision®-assisted colonoscopy (EAC) and conventional colonoscopy (CC)

Secondary

MeasureTime frameDescription
Mean number of adenomas detected per colonoscopy procedure18 monthsMean number of adenomas detected per colonoscopy procedure. This will be calculated after the first and second procedure to assess if there is a significant increase.
Number of sessile serrated lesions per procedure18 monthsNumber of sessile serrated lesions per procedure. This will be calculated after the first and second procedure to assess if there is a significant increase.
Total number of colon lesions found during first and second examination18 monthsThese polyps will be compared for size, colon distribution (coecum, ascending, transversum, descending, sigmoïd or rectum), morphologic (Paris classification) and histopathological characteristics (Vienna classification)
Difference in ADR (learning curve first 20% and last 20% by each colonoscopist)18 monthsTo compare the ADR of the first 20% of patients scoped by each colonoscopist with the last 20% of patients in each arm to identify any changes in ADR throughout the trial (to assess a learning curve) between CC and EC
Cecal intubation rate18 monthsTo compare cecal intubation rates between both techniques.
Adenoma detection rate (%)18 monthsTo compare adenoma detection rates (ADR) between Endocuff Vision®-assisted and CC.
Procedure times (minutes)18 monthsTo compare procedure times; total procedure time, insertion time, mean polypectomy time, withdrawal time)
Number of severe adverse events18 monthsTo compare the number of severe adverse events between study groups. 1 month follow-up
Sedation and analgesia use; type and amount18 monthsTo compare the use of sedation and analgesia between study groups. Type of sedation and analgesia and amount will be compared
Post-polypectomy surveillance guidelines; difference in surveillance intervals after the first and second procedure.18 monthsTo compare post-colonoscopy surveillance intervals applying European and US surveillance guidelines.
To compare patient reported outcomes e.g. pain18 monthsVisual Analog Scale 2 days and 1 month after the procedure
Bowel cleansing levels; using the Boston Bowel Preparation Scale (BBPS) ranging from 0-9)18 monthsTo compare BBPS scores between both techniques. A BBPS score of 2 or more in each colon segment is considered adequate.

Countries

Greece, Netherlands

Contacts

Primary ContactKelly van Keulen, MD
kelly.vankeulen@radboudumc.nl+31611910792

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 9, 2026