Skip to content

Comparison of 19g FNA and 19g FNB Needles for EUS-LB

19-Gauge Fine Needle Aspirate (FNA) Versus 19-Gauge Fine Needle Biopsy (FNB) Needles for Endoscopic Ultrasound Guided Liver Biopsy (EUS-LB): A Randomized Prospective Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03408171
Enrollment
40
Registered
2018-01-23
Start date
2017-10-02
Completion date
2018-08-17
Last updated
2020-04-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Abnormal Liver Function

Keywords

liver biopsy, endoscopic ultrasound guided liver biopsy, FNA, FNB

Brief summary

Chronic liver disorders (CLD) are a major cause of morbidity and mortality for individuals in the US. Though serologic analysis will often lead to a conclusive diagnosis, liver biopsy remains an important method for helping to determine the etiology and stage of LD. Percutaneous liver biopsy (PLB), transjugular liver biopsy (TLB) and surgical liver biopsy (SLB) are alternative methods for obtaining hepatic tissue. In recent years endoscopic ultrasound guided-liver biopsy (EUS-LB) has come to the forefront as a safe and effective method for obtaining tissue in CLD. There are several studies of the safety of EUS-LB as well as the adequacy of specimens obtained in this fashion. Most studies involve a 19-g needle, therefore in this study we hope to compare the tissue yields of a 19-g fine needle biopsy (FNB) needle, in comparison to conventional 19-g fine needle aspiration (FNA) needle. We predict that 19-g FNA and 19-g FNB needle will demonstrate similar diagnostic accuracy, with less visible blood artifact. Similarly, we predict the safety to be equal.

Interventions

DEVICE19-gauge FNA needle

A 19-gauge FNA needle will be used to obtain liver tissue during an endoscopic-ultrasound guided liver biopsy. Tissue yield and diagnostic accuracy will be assessed and compared to that of the 19-gauge FNB needle.

DEVICE19-gauge FNB needle

A 19-gauge FNB needle will be used to obtain liver tissue during an endoscopic-ultrasound guided liver biopsy. Tissue yield and diagnostic accuracy will be assessed and compared to that of the 19-gauge FNA needle.

Sponsors

Geisinger Clinic
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Intervention model description

Participants are assigned to one of two groups for the duration of the study.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patients undergoing EUS-LB 2. Platelet count \> 50,000 3. International normalized ratio (INR) \< 1.5 4. Age \> 18 years 5. Non-pregnant patients

Exclusion criteria

1. Age \< 18 years 2. Pregnant patients 3. Inability to obtain consent 4. Anticoagulants or anti-platelet agents use (excluding aspirin) within the last 7-10 days 5. Platelet count \< 50,000 6. INR \> 1.5 7. Presence of ascites 8. Known liver cirrhosis 9. Hemophilia

Design outcomes

Primary

MeasureTime frameDescription
Pre-processing Length of the Longest Piece (LLP)up to 5 daysPre-processing Length of the longest piece (LLP) measured in centimeter

Secondary

MeasureTime frameDescription
Number of Participants With LLP Pre-processing Length Less Than 2 cm or Greater Than 2 cm3-5 daysPre-processing Length of the longest piece (LLP) subgroups: \< 2 cm \> 2cm
Pre-processing Aggregate Specimen Length (ASL)3-5 daysPre-processing Aggregate specimen length (ASL) measured in centimeter
Post-processing Aggregate Specimen Length (ASL)3-5 daysPost-processing Aggregate specimen length (ASL) measured in centimeter
Portal Triads Number (Mean)3-5 daysNumber of portal triads (PT) in the specimen.
Post-processing Length of the Longest Piece (LLP)3-5 daysPost-processing Length of the longest piece (LLP) measured in centimeter
Number of Participants With Fewer Than 11 Portal Triads or More Than 11 Portal Triads3-5 daysPortal triads groups, n (%) \< 11 Portal triads \> 11 Portal triads
No. of Fragments > 9 mm, Mean (SD)3-5 daysNo. of fragments \> 9 mm, mean (SD) Pre-processing Post-processing
Specimen Quality for Histologic Diagnosis3-5 daysNumber of cases for which a histologic diagnosis could be made based upon the amount of tissue obtained with the needle.
Length of Longest PieceNumber Analyzed
Portal Triads Quantity (Median)3-5 daysNumber of portal triads (PT) in the specimen.

Countries

United States

Participant flow

Participants by arm

ArmCount
19-gauge FNA Needle
A 19-gauge FNA needle will be used to obtain liver tissue during an endoscopic-ultrasound guided liver biopsy. Tissue yield and diagnostic accuracy will be assessed and compared to that of the 19-gauge FNB needle. 19-gauge FNA needle: A 19-gauge FNA needle will be used to obtain liver tissue during an endoscopic-ultrasound guided liver biopsy. Tissue yield and diagnostic accuracy will be assessed and compared to that of the 19-gauge FNB needle.
20
19-gauge FNB Needle
A 19-gauge FNB needle will be used to obtain liver tissue during an endoscopic-ultrasound guided liver biopsy. Tissue yield and diagnostic accuracy will be assessed and compared to that of the 19-gauge FNA needle. 19-gauge FNB needle: A 19-gauge FNB needle will be used to obtain liver tissue during an endoscopic-ultrasound guided liver biopsy. Tissue yield and diagnostic accuracy will be assessed and compared to that of the 19-gauge FNA needle.
20
Total40

Baseline characteristics

Characteristic19-gauge FNA Needle19-gauge FNB NeedleTotal
Age, Continuous51 Years49 Years51 Years
Race/Ethnicity, Customized
Afroamerican
0 participants1 participants1 participants
Race/Ethnicity, Customized
Asian
1 participants0 participants1 participants
Race/Ethnicity, Customized
White (Hispanic)
1 participants3 participants4 participants
Race/Ethnicity, Customized
White (Non-hispanic)
18 participants16 participants34 participants
Region of Enrollment
United States
20 Participants20 Participants40 Participants
Sex: Female, Male
Female
9 Participants10 Participants19 Participants
Sex: Female, Male
Male
11 Participants10 Participants21 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 200 / 20
other
Total, other adverse events
8 / 207 / 20
serious
Total, serious adverse events
0 / 200 / 20

Outcome results

Primary

Pre-processing Length of the Longest Piece (LLP)

Pre-processing Length of the longest piece (LLP) measured in centimeter

Time frame: up to 5 days

ArmMeasureValue (MEAN)Dispersion
19-gauge FNA NeedlePre-processing Length of the Longest Piece (LLP)1.47 centimeterStandard Deviation 0.46
19-gauge FNB NeedlePre-processing Length of the Longest Piece (LLP)2.09 centimeterStandard Deviation 0.41
Secondary

Length of Longest Piece

Time frame: Number Analyzed

ArmMeasureValue (MEDIAN)
19-gauge FNA NeedleLength of Longest Piece32.3 mm
19-gauge FNB NeedleLength of Longest Piece30.2 mm
Secondary

No. of Fragments > 9 mm, Mean (SD)

No. of fragments \> 9 mm, mean (SD) Pre-processing Post-processing

Time frame: 3-5 days

ArmMeasureGroupValue (MEAN)Dispersion
19-gauge FNA NeedleNo. of Fragments > 9 mm, Mean (SD)Pre-processing3.5 Number of FragmentsStandard Deviation 2.4
19-gauge FNA NeedleNo. of Fragments > 9 mm, Mean (SD)Post-processing1.1 Number of FragmentsStandard Deviation 1
19-gauge FNB NeedleNo. of Fragments > 9 mm, Mean (SD)Pre-processing7.7 Number of FragmentsStandard Deviation 3.7
19-gauge FNB NeedleNo. of Fragments > 9 mm, Mean (SD)Post-processing4.8 Number of FragmentsStandard Deviation 3.6
Secondary

Number of Participants With Fewer Than 11 Portal Triads or More Than 11 Portal Triads

Portal triads groups, n (%) \< 11 Portal triads \> 11 Portal triads

Time frame: 3-5 days

ArmMeasureCategoryValue (COUNT_OF_PARTICIPANTS)
19-gauge FNA NeedleNumber of Participants With Fewer Than 11 Portal Triads or More Than 11 Portal Triads< 11 Portal triads6 Participants
19-gauge FNA NeedleNumber of Participants With Fewer Than 11 Portal Triads or More Than 11 Portal Triads> Portal triads14 Participants
19-gauge FNB NeedleNumber of Participants With Fewer Than 11 Portal Triads or More Than 11 Portal Triads< 11 Portal triads2 Participants
19-gauge FNB NeedleNumber of Participants With Fewer Than 11 Portal Triads or More Than 11 Portal Triads> Portal triads18 Participants
Secondary

Number of Participants With LLP Pre-processing Length Less Than 2 cm or Greater Than 2 cm

Pre-processing Length of the longest piece (LLP) subgroups: \< 2 cm \> 2cm

Time frame: 3-5 days

ArmMeasureCategoryValue (COUNT_OF_PARTICIPANTS)
19-gauge FNA NeedleNumber of Participants With LLP Pre-processing Length Less Than 2 cm or Greater Than 2 cm< 2 cm17 Participants
19-gauge FNA NeedleNumber of Participants With LLP Pre-processing Length Less Than 2 cm or Greater Than 2 cm> 2 cm3 Participants
19-gauge FNB NeedleNumber of Participants With LLP Pre-processing Length Less Than 2 cm or Greater Than 2 cm< 2 cm10 Participants
19-gauge FNB NeedleNumber of Participants With LLP Pre-processing Length Less Than 2 cm or Greater Than 2 cm> 2 cm10 Participants
Secondary

Portal Triads Number (Mean)

Number of portal triads (PT) in the specimen.

Time frame: 3-5 days

ArmMeasureValue (MEAN)Dispersion
19-gauge FNA NeedlePortal Triads Number (Mean)18.1 Portal TriadsStandard Deviation 9.3
19-gauge FNB NeedlePortal Triads Number (Mean)42.6 Portal TriadsStandard Deviation 25
Secondary

Portal Triads Quantity (Median)

Number of portal triads (PT) in the specimen.

Time frame: 3-5 days

ArmMeasureValue (MEDIAN)
19-gauge FNA NeedlePortal Triads Quantity (Median)16.5 Complete number of portal triads
19-gauge FNB NeedlePortal Triads Quantity (Median)38 Complete number of portal triads
Secondary

Post-processing Aggregate Specimen Length (ASL)

Post-processing Aggregate specimen length (ASL) measured in centimeter

Time frame: 3-5 days

ArmMeasureValue (MEAN)Dispersion
19-gauge FNA NeedlePost-processing Aggregate Specimen Length (ASL)11.4 centimeterStandard Deviation 5.55
19-gauge FNB NeedlePost-processing Aggregate Specimen Length (ASL)15.32 centimeterStandard Deviation 5.24
Secondary

Post-processing Length of the Longest Piece (LLP)

Post-processing Length of the longest piece (LLP) measured in centimeter

Time frame: 3-5 days

ArmMeasureValue (MEAN)Dispersion
19-gauge FNA NeedlePost-processing Length of the Longest Piece (LLP)1.05 centimeterStandard Deviation 0.42
19-gauge FNB NeedlePost-processing Length of the Longest Piece (LLP)1.78 centimeterStandard Deviation 0.66
Secondary

Pre-processing Aggregate Specimen Length (ASL)

Pre-processing Aggregate specimen length (ASL) measured in centimeter

Time frame: 3-5 days

ArmMeasureValue (MEAN)Dispersion
19-gauge FNA NeedlePre-processing Aggregate Specimen Length (ASL)10.89 centimeterStandard Deviation 4.38
19-gauge FNB NeedlePre-processing Aggregate Specimen Length (ASL)15.78 centimeterStandard Deviation 5.19
Secondary

Specimen Quality for Histologic Diagnosis

Number of cases for which a histologic diagnosis could be made based upon the amount of tissue obtained with the needle.

Time frame: 3-5 days

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
19-gauge FNA NeedleSpecimen Quality for Histologic Diagnosis20 Participants
19-gauge FNB NeedleSpecimen Quality for Histologic Diagnosis20 Participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026