Study of a Suprachoroidal Retinal Prosthesis

Evaluation of a Suprachoroidal Retinal Prosthesis: A 44 Channel Fully Implantable Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03406416
Enrollment
4
Registered
2018-01-23
Start date
2018-02-13
Completion date
2020-12-18
Last updated
2021-08-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Choroideremia, Retinitis Pigmentosa

Brief summary

This study is a proof of principal, to evaluate a safety and efficacy of a prototype suprachoroidal retinal implant.

Detailed description

Retinal visual prostheses are currently in early development as an intervention to improve functional vision in people who have become blind from retinal degenerative eye disease. This study follows on from an initial proof of concept study (n=3) between 2012 and 2014, and will test a second-generation retinal prosthesis device, which has the ability to be used outside of the laboratory environment (i.e. is fully implantable).

Interventions

DEVICE44Ch Bionic Eye Device

Prototype wide view suprachoroidal retinal prosthesis

Sponsors

Bionic Vision Technologies
CollaboratorUNKNOWN
Center for Eye Research Australia
CollaboratorOTHER
The Bionics Institute of Australia
CollaboratorOTHER
University of Melbourne
CollaboratorOTHER
Data 61 CSIRO
CollaboratorUNKNOWN
Australian National University
CollaboratorOTHER
Mobius Medical Pty Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Aged 18 years or older * Either gender * A confirmed history of outer retinal degenerative disease such as retinitis pigmentosa or choroideremia * Remaining visual acuity of bare light perception or less in both eyes * Functional inner retina (ganglion cells and optic nerve), as shown by the ability to perceive light and/or a measurable corneal electrically evoked visual response * A history of at least 10 years of useful form vision in the worse seeing eye

Exclusion criteria

* Optic nerve disease (history of glaucoma of More than 1 month, or history of any other optic neuropathy) * Diseases of the inner retina including, but not limited to, central retinal artery or vein occlusion (CRAO, CRVO), end stage diabetic retinopathy, retinal detachment, traumatic retinal damage, infectious retinal disease, inflammatory retinal disease. * Inability to visualise the retina due to corneal or other ocular media opacities (corneal degenerations, dense cataracts, trauma, lid malpositions) * Any ocular condition that predisposes the participant to rubbing their eyes * Cognitive deficiencies, including dementia or progressive neurological disease * Psychiatric disorders, including depression, as diagnosed by a qualified psychologist * Deafness or significant hearing loss * Inability to speak or understand English * Pregnancy * Presence of a cochlear implant * Participant enrolled in another investigational drug or device trial for the treatment of their ocular condition * Poor general health, which would exclude them from obtaining a general anaesthetic * Unrealistic expectations of the investigational device to provide functional vision * Poorly controlled diabetes * Epilepsy * Unsuitable level of regular nystagmus (which would prevent ocular images from being obtained) * Anyone with medical devices (implanted or carried) that could cause serious health problems if compromised by electro-magnetic interference

Design outcomes

Primary

MeasureTime frameDescription
Number and severity of device related serious adverse events (SAEs)2 yearsThe safety of the surgical implantation assessed by the number and severity of serious adverse events (SAEs) compared to other retinal prosthesis.

Secondary

MeasureTime frameDescription
Efficacy - visual response2 yearsThe ability to generate a visual response accessed via repeatable threshold measurements of visual perception.
Visual Function and Functional Vision2 yearsVisual function and Functional Vision will be scored from performance on a range of acuity, orientation and mobility, and activities of daily living tasks. Outcome measures include: 1. Grating visual acuity: record the grating acuity level and average response time. 2. Square localization: response error and response time is measured. 3. Motion detection: response error and response time is measured. 4. Table top task: locate and identify objects on a table. Accuracy rates and response times will be recorded. 5. Doorway detection task: to find doorway target. Task time and accuracy of door touch will be recorded. 6. Obstacle avoidance task: task time and number of collisions is recorded. 7. Functional Low Vision Observer Rated Assessment (FLORA): this assessment tool Is used to evaluate participant functional vision and mobility.
Quality of life - IVI - very low vision validated questionnaire2 yearsQuality of life will be assessed via survey and self-report. The Functional Low Vision Observer Assessment (FLORA) is a questionnaire that will be used to measure participants changes in participant daily living experiences.