Brief summary

Postpartum hemorrhage (PPH) is the leading cause of maternal mortality in low-income countries and the primary cause of nearly one quarter of all maternal deaths globally. Estimates of blood loss at delivery are notoriously inaccurate, with under-estimation more common than over-estimation. Traditionally, the surgeon performing the cesarean section would estimate the blood loss by visually assessing the blood collected in the surgical drape and counting the number of lap sponges used thru out the procedure. The investigators would like to study and validate an FDA approved device called the gauss Triton device used to estimate blood loss during scheduled cesarean sections.

Detailed description

According to the World Health Organization, postpartum hemorrhage (PPH) is the leading cause of maternal mortality in low-income countries and the primary cause of nearly one quarter of all maternal deaths globally. An estimated blood loss (EBL) in excess of 500 mL following a vaginal birth or a loss of greater than 1,000 mL following cesarean birth often have been used for the definition of postpartum hemorrhage, but the average volume of blood lost at delivery can approach these amounts when actually measured rather than estimated. More than half of all maternal deaths occur within 24 hours of delivery, most commonly from excessive bleeding. Worldwide, 140,000 women succumb to postpartum hemorrhage each year. The most common antecedents to postpartum hemorrhage are uterine atony, placental disorders, and trauma during delivery. Improving maternal health worldwide is one of the WHO's 8 Millennium Developmental Goals. The prevention and treatment of PPH is an essential step towards the achievement of that goal. Estimates of blood loss at delivery are notoriously inaccurate, with under-estimation more common than over-estimation. Traditionally, the surgeon performing the cesarean section would estimate the blood loss by visually assessing the blood collected in the surgical drape and counting the number of lap sponges used thru out the procedure. Current detection and management of hemorrhage is heavily based on clinical judgment, which often leads to delay in recognition and intervention. Often, interventions such as fluid resuscitation and blood transfusion are not initiated until significant hemorrhage has already taken place. The traditional method for estimating blood loss is based on the surgeon and surgical staff's subjective assessment that is severely limited by human error and the presence of large volumes of amniotic fluid, irrigation, or both. Another limitation is that blood loss is frequently estimated at the end of the procedure. Early detection and treatment of this potentially life threatening obstetric complication is of utmost importance in the field of obstetrics. Simulations and didactic training have been shown to improve visual estimations, but there are still poor associations between experience level and accuracy, and a significant decay in blood loss estimation skills over time. The Triton system (Gauss Surgical, Inc., Palo Alto, CA) is a novel mobile monitoring platform that combines mobile computing with Gauss Feature Extraction Technology (FET) to directly assess Hb mass (mHb) absorbed by surgical sponges from an image. The device is an iPad like imaging device that will assess blood loss via imaging of the surgical sponges used in the surgery. In 2014, Konig at al. showed that mobile blood loss monitoring using the Triton system is accurate in assessing mHb on surgical sponges across a range of ambient light conditions, sponge saturation, saline contamination, and initial blood Hb. Utilization of this tool could significantly improve the accuracy of blood loss estimates. Holmes et al. also showed that the novel mobile monitoring system provides an accurate measurement of mHb on surgical sponges as compared with manual rinsing measurements, and is significantly more accurate than the gravimetric method. However, these studies were performed on patients undergoing a myriad of surgical procedures not just limited to obstetrical patients. To the investigators' knowledge, this technology has not been validated in the obstetrical population at risk for hemorrhage. The gauss/triton colorimetric system is not standard of care at UTMB. Not enough data is available to support its use, despite being FDA approved to estimate blood loss. Most evidence is available in non-pregnant patients. In the obstetric population no definitive evidence exists, and the only trial that has been performed was recently published in AJP reports. In that trial, only the accuracy was evaluated, and the investigators believe that further evidence is needed to support its use. The investigators' hypothesis is that this device will enable clinicians to prospectively and objectively assess EBL. Ultimately after its validation, their results will be used to propose a multicenter clinical trial to the NICHD MFMU network to evaluate the clinical utility of this system. This study will be a prospective cohort study, in which the investigators will evaluate two methods of evaluating intraoperative blood loss during cesarean delivery (usual clinical assessment versus Device). Of note, the subjects consented will be used as self-controls. Patients who are scheduled for an elective cesarean and meet criteria for inclusion in the study will be approached for participation at same day of admission. Written informed consent will be obtained from the patients. If patients agree to participate, a CBC (complete blood count) will be obtained via venous puncture. The device will be used during the delivery in the operating room. The device will be used to assess EBL by the research staff only and results/ EBL assessment will be masked to the clinical team. Unmasking will only occur after collecting the data from the device with purpose to perform data analysis. Patient management will be according to the clinical team. All patients undergo a CBC postpartum. The drop in Hgb (ΔHgb) between the pre and post cesarean CBCs will be calculated for each patient. Patients will be divided into quartiles of ΔHgb. Cases will be those patients whose ΔHgb is in the upper quartile, while controls will be those patients whose ΔHgb is in the lower 3 quartiles. The investigators will be comparing EBL by standard clinical assessment versus result from the device between cases and controls.

Interventions

DEVICEGauss Triton system

The Triton system (Gauss Surgical, Inc., Palo Alto, CA) is a novel mobile monitoring platform that combines mobile computing with Gauss Feature Extraction Technology (FET) to directly assess Hb mass (mHb) absorbed by surgical sponges from an image. The device is an iPad like imaging device that will assess blood loss via imaging of the surgical sponges used in the surgery. The device will be used to calculate blood loss on every patient enrolled in the study.

Sponsors

The University of Texas Medical Branch, Galveston
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

* Pregnant women between the ages of 18-50 * Scheduled cesarean delivery

Exclusion criteria

* Incarcerated patients * Patient unwilling or unable to provide consent * Intrauterine fetal demise (no fetal heart beat identified and documented by two physicians) * Placenta previa or other known placental anomalies * Enrolled in another trial that may affect outcome.

Design outcomes

Primary

MeasureTime frameDescription
Clinical Estimated Blood Loss (EBL) Between Cases and Controls Using Clinical Estimate Versus Device Assessment48 hoursThe investigators are looking at the difference between the EBL measured clinically and the EBL measured using the Gauss device
Triton Device Estimated Blood Loss (EBL) Between Cases and Controls Using Clinical Estimate Versus Device Assessment48 hoursThe investigators are looking at the difference between the EBL measured clinically and the EBL measured using the Gauss device (Triton)

Secondary

MeasureTime frameDescription
Transfusion Requirements48 hoursNumber of participants that received blood transfusion
Number of Participants With Post-partum Hemorrhage48 hoursthe number of cases of post partum hemorrhage

Countries

United States

Participant flow

Participants by arm

ArmCount
Cases
Cases defined as delta hemoglobin in the upper quartile
70
Control
Controls defined as delta hemoglobin in the lower quartile
172
Total242

Baseline characteristics

CharacteristicCasesControlTotal
Age, Continuous30 years29 years29 years
Ethnicity (NIH/OMB)
Hispanic or Latino
26 Participants69 Participants95 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
44 Participants103 Participants147 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Region of Enrollment
United States
70 participants172 participants242 participants
Sex: Female, Male
Female
70 Participants172 Participants242 Participants
Sex: Female, Male
Male
0 Participants0 Participants0 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 700 / 172
other
Total, other adverse events
8 / 7011 / 172
serious
Total, serious adverse events
0 / 700 / 172

Outcome results

Primary

Clinical Estimated Blood Loss (EBL) Between Cases and Controls Using Clinical Estimate Versus Device Assessment

The investigators are looking at the difference between the EBL measured clinically and the EBL measured using the Gauss device

Time frame: 48 hours

ArmMeasureValue (MEDIAN)
CasesClinical Estimated Blood Loss (EBL) Between Cases and Controls Using Clinical Estimate Versus Device Assessment800 milliLiters
ControlClinical Estimated Blood Loss (EBL) Between Cases and Controls Using Clinical Estimate Versus Device Assessment800 milliLiters
Primary

Triton Device Estimated Blood Loss (EBL) Between Cases and Controls Using Clinical Estimate Versus Device Assessment

The investigators are looking at the difference between the EBL measured clinically and the EBL measured using the Gauss device (Triton)

Time frame: 48 hours

ArmMeasureValue (MEDIAN)
CasesTriton Device Estimated Blood Loss (EBL) Between Cases and Controls Using Clinical Estimate Versus Device Assessment474 milliLiters
ControlTriton Device Estimated Blood Loss (EBL) Between Cases and Controls Using Clinical Estimate Versus Device Assessment331 milliLiters
Secondary

Number of Participants With Post-partum Hemorrhage

the number of cases of post partum hemorrhage

Time frame: 48 hours

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
CasesNumber of Participants With Post-partum Hemorrhage8 Participants
ControlNumber of Participants With Post-partum Hemorrhage11 Participants
Secondary

Transfusion Requirements

Number of participants that received blood transfusion

Time frame: 48 hours

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
CasesTransfusion Requirements0 Participants
ControlTransfusion Requirements1 Participants