Skip to content

The Right Heart During and After Pregnancy - an Echocardiographic Study

Das Rechte Herz in Der Schwangerschaft. Echokardiographische Verlaufskontrollen Des Rechten Herzens während Und Nach Der Schwangerschaft.

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03402971
Acronym
EVA
Enrollment
1000
Registered
2018-01-18
Start date
2017-11-02
Completion date
2024-11-02
Last updated
2021-04-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pregnancy Related

Keywords

right heart, pregnancy, echocardiography, reference values

Brief summary

The main goal is to establish echocardiographic reference values of the right heart for pregnant women, assuming they differ significantly from those of non pregnant women of same age. Therefore the investigators will use existing reference values published by American society of echocardiography and European Association of Echocardiography. As side arms the investigators want to explore, whether illness of either fetus or mother is connected with right heart affection.

Detailed description

A lot of lung diseases affect the heart, too - especially the right heart. Well known examples are pulmonary embolism or pulmonary hypertension. But rather unknown is the fact, that right heart function presents as a prognostic parameter in a lot of (left heart) diseases, for example myocardial infarction, atrial fibrillation, left heart failure, but also in chronic obstructive pulmonary disease (COPD) or may be even diabetes mellitus. Since the left part of the heart has been studied by researchers more than fifty years, the right heart has moved into scientific focus not long ago. The tool of choice to examine the living heart is echocardiography. There are no relevant risks or complications. During an echocardiographic examination a lot of parameters are collected. To judge data in a clinical way reference values belonging to healthy persons are essential. Those values are highly dependant on sex, body size, age etc. Since pregnancy changes a lot in the human body, reference values from non pregnant woman of same age (published by American society of echocardiography and European Association of Echocardiography) are presumably not representative. So the investigators want to establish echocardiographic reference values of the right heart for pregnant women. Therefore an echocardiographic examination will be applied within each trimester of pregnancy and after delivery. As side arms the investigators want to explore, whether illness of either fetus or mother is connected with right heart affection.

Interventions

DIAGNOSTIC_TESTechocardiography

echocardiography focused on right heart: Parameters include RV enddiastolic diameter basal, mid-cavity and longitudinal, RVOT distal, pulmonal outflow AT and AT/ET, endsystolic RA area. RV wall thickness, TAPSE, S', tricuspidal E/A, E/e', RIMP. V. Cava to estimate CVP and sPAP.

Sponsors

Gero Bunniger
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum

Inclusion criteria

* pregnant * 18years or older

Exclusion criteria

* acute illness demanding instant therapy * poor or none sonographic results

Design outcomes

Primary

MeasureTime frameDescription
change in right ventricular (RV) enddiastolic diameter basalfirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure right ventricular (RV) enddiastolic diameter basal (unit: mm), via echocardiography in apical 4 Chamber view, EKG-controlled.
change in RV enddiastolic diameter mid-cavitiyfirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure right ventricular RV enddiastolic diameter mid-cavity (unit: mm), via echocardiography in apical 4 Chamber view, EKG-controlled.
change in RV enddiastolic diameter longitudinalfirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure right ventricular RV enddiastolic diameter longitudinal (unit: mm), via echocardiography in apical 4 Chamber view, EKG-controlled.
change in right ventricular outflow tract (RVOT) distalfirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure RVOT distal (unit: mm), via echocardiography in parasternal short-axis view, EKG-controlled.
change in right atrial (RA) endsystolic areafirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure RA endsystolic area (unit: cm²), via echocardiography in apical 4 Chamber view, EKG-controlled.
change in RV wall thicknessfirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure RV wall thickness (unit: mm), via echocardiography in subcostal view, EKG-controlled. RV wall \>5mm indicates RV hypertrophy.
change in tricuspid annular plane systolic excursion (TAPSE)first examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure TAPSE (unit: mm), via echocardiography in apical 4 Chamber view + M-Mode at lateral tricuspid annulus, EKG-controlled. TAPSE is a parameter describing systolic RV-function.
change in S' velocityfirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure S' velocity (unit: cm/sec), via echocardiography in apical 4 Chamber view + pulsed tissue Doppler velocity of the lateral tricuspid annulus, EKG-controlled. S' is a parameter describing systolic RV-function.
change in tricuspid E/A ratiofirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure tricuspidal E/A ratio (unit: no unit), via echocardiography in apical 4 Chamber view + pulsed wave doppler over tricuspid inflow, EKG-controlled. Tricuspid E/A ratio is a parameter describing diastolic RV-function.
change in tricuspid E/e' ratiofirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure tricuspid E/e' ratio (unit: no unit), via echocardiography in apical 4 Chamber view + pulsed wave doppler over tricuspid inflow + pulsed tissue Doppler velocity of the lateral tricuspid annulus, EKG-controlled. Tricuspid E/e' ratio is a parameter describing diastolic RV-function.
change in right index of myocardial performance (RIMP)first examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure RIMP (unit: no unit), via echocardiography in apical 4 Chamber view + pulsed tissue Doppler velocity of the lateral tricuspid annulus, EKG-controlled. RIMP is calculated (isovolumic contraction time + isovolumic relaxation time) devided by (ejection time). RIMP is a parameter describing systolic RV-function.
change in inferior vena cava (IVC) diameter at end-expirationfirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure IVC (unit: mm) via echocardiography subcostal or IVC view at end-expiration. IVC diameter correlates with central venous pressure.
change in inferior vena cava (IVC) diameter with sniff test.first examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure IVC (unit: mm) via echocardiography subcostal or IVC view at forced inspiration. IVC diameter correlates with central venous pressure.
change in tricuspid regurgitation peak velocityfirst examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure tricuspid regurgitation peak velocity (unit: m/sec) via echocardiography in apical 4 Chamber view + continuous wave doppler over tricuspid inflow respectively tricuspid regurgitation, if there is a tricuspid insufficiency, EKG-controlled. Tricuspid regurgitation peak velocity correlates with systolic pulmonary artery pressure (sPAP).
change in RV outflow tract acceleration time (RVOT-AT)first examination within 1st to 12th week of pregnancy, second examination within 13th to 28th week of pregnancy, third examination after 28th week of pregnancy and before delivery, fourth examination will take place at least 14 days after deliveryThe investigators measure RVOT-AT (unit: msec) via echocardiography in parasternal short-axis view + pulsed wave doppler over pulmonal valve, EKG-controlled. RVOT-AT correlates with systolic pulmonary artery pressure (sPAP).

Countries

Germany

Contacts

Primary ContactGero Bunniger
gero.bunniger@innere.med.uni-giessen.de+49641 985 56082
Backup ContactHenning Gall, Prof., MD
henning.gall@innere.med.uni-giessen.de+49 641 985 57030

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026