Skip to content

Role of the Wearable Cardioverter Defibrillator in Tachycardia Induced Cardiomyopathy

Role of the Wearable Cardioverter Defibrillator in Tachycardia Induced Cardiomyopathy. A Prospective Study

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03388905
Enrollment
30
Registered
2018-01-03
Start date
2018-01-15
Completion date
2019-12-31
Last updated
2018-01-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tachycardia-induced Cardiomyopathy

Keywords

LifeVest wearable, cardioverter defibrillator, LVEF

Brief summary

The purpose of this current study is to prospectively enroll consecutive patients hospitalized with newly diagnosed severe left ventricular dysfunction (LVEF ≤ 35%) for which the likely etiology is uncontrolled atrial fibrillation or high burden of ventricular ectopy. Patients completing their established in-hospital treatment plan with rate or rhythm control, will be discharged with a WCD following informed consent and detailed counseling by healthcare personnel for a time-period of up to 3 months until reassessment of LVEF and the need for ICD implantation.

Detailed description

TachycardiaInduced Cardiomyopathy (TICMP) refers to impairment in left ventricular function secondary to chronic tachycardia, which is partially or completely reversible once the tachyarrhythmia is controlled. Tachycardia-induced cardiomyopathy has been shown to occur both in experimental models and in patients with incessant tachyarrhythmia (mostly commonly uncontrolled atrial fibrillation). Control of ventricular rate or rhythm by means of cardio-version, negative chronotropic agents, anti-arrhythmic medication and surgical or catheter-based ablation, resulted in significant improvement of systolic function. However, until a possible improvement in left ventricular ejection fraction (LVEF), patients with TICMP with severely depressed systolic function may remain at a high-risk for life-threatening ventricular arrhythmias and sudden cardiac death. While implantable cardioverter defibrillators (ICD) are indicated in patients who fail to improve their left ventricular ejection fraction (LVEF), currently there is no protection from sudden cardiac death (SCD) in patients with TICMP during the high-risk time period from hospital discharge until reassessment of cardiac function and the need for ICD implantation. In this population, the Life Vest wearable cardioverter defibrillator (WCD) may be an appropriate treatment option, providing protection from SCD through timely termination of life-threatening ventricular arrhythmias until stabilization of LVEF. In addition, the monitoring capabilities of the WCD may facilitate remote assessment heart rate control with appropriate titration of medical therapy and evaluation of recurrence of tachyarrhythmias following discharge from hospitalization. Accordingly, the proposed study is the first to prospectively evaluate the benefit of the WCD as an early management strategy in patients with TICMP. There is no available clinical research data to date on the study device used in TICMP. This proposed trial is a multicenter single armed prospective study. Thirty patients with newly diagnosed severe LV dysfunction due to uncontrolled tachyarrhythmia will be enrolled following their completion of established in-hospital treatment plan with rate or rhythm control. Enrolled patients will be discharged with a WCD for a time-period of 3 months. All patients will provide signed informed consent, and detailed counseling by healthcare personnel for a time-period of up to 3 months until reassessment of LVEF and the need for ICD implantation. The enrollment duration is expected to last 12 months and follow up of additional 12 months from patient inclusion will be performed. An estimation recruitment rate of 1-2 patients per month per center is reasonable based on our preliminary data (see section 6.1). Therefore, it is likely to end up patient's recruitment 10 months following the enrollment phase initiation. During follow up, patients will be contacted at (1) end of WCD use (2) 3 month and (3) 12 months post enrollment. Total expected duration of study termination is 24 months from the time first patient was enrolled.

Interventions

DEVICELife Vest Wearable defibrilator

The LifeVest is a cardioverter defibrillator worn by a patient at risk for sudden cardiac arrest (SCA). It monitors the patient's heart continuously and, if the patient goes into a life-threatening arrhythmia, can deliver a shock treatment to restore the patient's heart to normal rhythm.

Sponsors

Sheba Medical Center
Lead SponsorOTHER_GOV

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with newly diagnosed left ventricular dysfunction (LVEF ≤ 35% following cardioversion or rate stabilization) with either of the following: * Newly diagnosed atrial fibrillation * High burden of premature ventricular contractions (PVCs) (15% of total beats on 24-hour ambulatory Holter recording with a rapid ventricular response \> 100 beats per minute prior to initiation of medical therapy) and no other likely heart failure (HF) etiology * Appropriate management during hospitalization with cardioversion and rhythm control (preferable) or rate control (if cardioversion is contraindicated due to a left atrial thrombus or is not successful)

Exclusion criteria

* HF likely due to an etiology other than tachyarrhythmia (ischemic etiology, myocarditis, hypertrophic or dilated cardiomyopathy, etc.) * Unstable clinical condition, life threatening arrhythmia or an established indication for ICD/CRT-D implantation during the index hospitalization * Patients with ICD/CRT-D or established (\> 3 months) heart failure * Cognitive impairment or unable to utilize WCD appropriately * Patient has a chest circumference at the level of the xiphoid process either less than 26 inches or greater than 56 inches

Design outcomes

Primary

MeasureTime frameDescription
Left ventricular recovery following WCD use.3 monthsLeft ventricular recovery following WCD use.

Secondary

MeasureTime frameDescription
Recurrence of atrial tachyarrhythmias12 monthsRecurrence of atrial tachyarrhythmias
Recurrence of ventricular tachyarrhythmias12 monthsRecurrence of ventricular tachyarrhythmias
Appropriate shocks by WCD3 monthsOccurrence of appropriate shocks as recorded by WCD (number of Shocks delivered during the follow up period)
Inappropriate shocks by WCD3 monthsOccurrence of Inappropriate shocks as recorded by WCD (number of Inappropriate Shocks delivered during the follow up period)

Countries

Israel

Contacts

Primary ContactIlan Goldenberg, Prof
Ilan.Goldenberg@sheba.health.gov.il972-3-532848
Backup ContactNava Levine

Outcome results

None listed