Skip to content

A Pilot Test of t:Slim X2 With Control-IQ Technology

The International Diabetes Closed Loop (iDCL) Trial: Clinical Acceptance of the Artificial Pancreas - A Pilot Test of t:Slim X2 With Control-IQ Technology

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03368937
Enrollment
5
Registered
2017-12-11
Start date
2017-12-08
Completion date
2017-12-11
Last updated
2022-05-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Type1 Diabetes Mellitus

Keywords

Artificial Pancreas (AP), Closed Loop Control (CLC), Continuous Glucose Monitor (CGM), Insulin Pump

Brief summary

A 36-48 hour admission testing the t:slim X2 with Control-IQ Technology

Detailed description

The objective of the study is for clinical staff to gain experience using the proposed artificial pancreas system named t:slim X2 with Control-IQ Technology and assess usability in a supervised setting prior to initiating home use in a Training protocol.

Interventions

Subjects will wear the Tandem t:slim X2 with Control-IQ Technology during a 36-48 hour hotel admission.

Sponsors

Tandem Diabetes Care, Inc.
CollaboratorINDUSTRY
DexCom, Inc.
CollaboratorINDUSTRY
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
CollaboratorNIH
University of Virginia
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 74 Years
Healthy volunteers
No

Inclusion criteria

To be eligible for the study, a subject must meet the following criteria: 1. Clinical diagnosis, based on investigator assessment, of type 1 diabetes for at least one year and using insulin for at least 1 year 2. Use of an insulin pump for at least 6 months with established parameters for basal rate(s), carbohydrate ratio(s) and insulin sensitivity factor(s) for at least 3 months. 3. Age 18.0 to \<75.0 years 4. Hemoglobin A1c \<10.5% 5. For females, not currently known to be pregnant If female and sexually active, must agree to use a form of contraception to prevent pregnancy while a subject in the study. A negative serum or urine pregnancy test will be required for all premenopausal women who are not surgically sterile. Subjects who become pregnant will be discontinued from the study. Also, subjects who during the study develop and express the intention to become pregnant within the timespan of the study will be discontinued. 6. Willingness to suspend use of any personal CGM for the duration of the clinical trial once the study CGM is in use 7. Investigator has confidence that the subject can successfully operate all study devices and is capable of adhering to the protocol 8. Currently using no insulins other than one of the following rapid-acting insulins at the time of enrollment: insulin lispro (Humalog), insulin aspart (Novolog), or insulin glulisine (Apidra). Willingness to switch to lispro (Humalog) or aspart (Novolog) if using glulisine (Apidra). 9. Total daily insulin dose (TDD) at least 10 U/day and ≤100 U/day 10. Weight at least 25 kg and not greater than 140 kg

Exclusion criteria

1. More than one episode of diabetic ketoacidosis (DKA) in the 6 months prior to enrollment 2. More than one episode of severe hypoglycemia involving seizure or loss of consciousness in the 6 months prior to enrollment 3. Concurrent use of any non-insulin glucose-lowering agent (including GLP-1 agonists, Symlin, DPP-4 inhibitors, SGLT-2 inhibitors, biguanides, sulfonylureas and naturaceuticals). 4. Hemophilia or any other bleeding disorder 5. A condition, which in the opinion of the investigator or designee, would put the subject or study at risk 6. Participation in another pharmaceutical or device trial at the time of enrollment or during the study 7. Employed by, or having immediate family members employed by Tandem Diabetes Care, Inc. or TypeZero Technologies, LLC, or having a direct supervisor at place of employment who is also directly involved in conducting the clinical trial (as a study investigator, coordinator, etc.); or having a first-degree relative who is directly involved in conducting the clinical trial

Design outcomes

Primary

MeasureTime frameDescription
System Suitability36-48 hoursTechnology Acceptance Questionnaire Score Scores are on a Likert Scale of 1-Not at All to 5-Extremely for Ease of Use, Usability and Trust in System Scores.

Countries

United States

Participant flow

Participants by arm

ArmCount
Tandem t:Slim X2 With Control-IQ Technology
Subjects will use the Tandem t:slim X2 with Control-IQ Technology during a 36-48 hour hotel admission. Tandem t:slim X2 with Control-IQ Technology: Subjects will wear the Tandem t:slim X2 with Control-IQ Technology during a 36-48 hour hotel admission.
5
Total5

Baseline characteristics

CharacteristicTandem t:Slim X2 With Control-IQ Technology
Age, Continuous52.8 years
STANDARD_DEVIATION 15.9
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
0 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
5 Participants
Region of Enrollment
United States
5 participants
Sex: Female, Male
Female
3 Participants
Sex: Female, Male
Male
2 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 5
other
Total, other adverse events
0 / 5
serious
Total, serious adverse events
0 / 5

Outcome results

Primary

System Suitability

Technology Acceptance Questionnaire Score Scores are on a Likert Scale of 1-Not at All to 5-Extremely for Ease of Use, Usability and Trust in System Scores.

Time frame: 36-48 hours

ArmMeasureGroupValue (MEAN)
Tandem t:Slim X2 With Control-IQ TechnologySystem SuitabilityEase of Use5 score on a scale
Tandem t:Slim X2 With Control-IQ TechnologySystem SuitabilityUsefulness4.8 score on a scale
Tandem t:Slim X2 With Control-IQ TechnologySystem SuitabilityTrust in System5 score on a scale

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026