Skip to content

Endorotor Resection In Refractory Barrett's Dysplasia Patients

Interscope Endorotor® Mucosal Resection System With Continued Ablative Therapy In Subjects With Refractory Dysplastic Barrett's Esophagus

Status
Terminated
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03364114
Enrollment
15
Registered
2017-12-06
Start date
2018-02-09
Completion date
2026-03-24
Last updated
2026-03-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Barrett's Esophagus With Dysplasia

Brief summary

The aim of the clinical trial is to evaluate the EndoRotor®'s ability to completely remove areas of Barrett's esophagus considered refractory after 3 failed ablation treatments (Radiofrequency Ablation (RFA) and/or Cryotherapy) or in patients with at least 1 failed ablative procedure (RFA and/or Cryotherapy) and are intolerant to the procedure due to pain, where intolerant is defined as post-dysphagia or odynophagia persisting for 24 hours or greater or requiring narcotic analgesia for a duration of more than 24 hours.

Detailed description

Prospective, multi-center, randomized controlled trial, pivotal, investigational device exemption (IDE) to compare the safety and performance of the EndoRotor® Mucosal Resection System with continued ablative therapy in subjects with refractory Barrett's Esophagus. The EndoRotor® Endoscopic Mucosal Resection System is an automated mechanical endoscopic mucosal resection system for use in the gastrointestinal tract for benign neoplastic or pre-malignant tissue removal by interventional gastroenterologists and GI surgeons. The EndoRotor® System performs both tissue dissection and resection with a single device through an endoscope's instrument biopsy channel.

Interventions

DEVICEEndoRotor Mucosal Resection System

The EndoRotor® Endoscopic Mucosal Resection System is an automated mechanical endoscopic mucosal resection system for use in the gastrointestinal tract for benign neoplastic or pre-malignant tissue removal by interventional gastroenterologists and GI surgeons. The EndoRotor® System performs both tissue dissection and resection with a single device through an endoscope's instrument biopsy channel.

DEVICEContinued Ablation

Continued ablation control shall include either cryotherapy or continued radial frequency ablation.

Sponsors

Interscope, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
30 Years to 89 Years
Healthy volunteers
No

Inclusion criteria

1. Subjects who are greater than 30 and less than 90 years of age; inclusive of males and females. 2. Subjects with confirmed Barrett's esophagus with dysplasia (low-grade or high-grade) and meeting at least one of the following criteria: 1. Failed 3 ablative procedures (RFA and/or Cryotherapy). 2. Failed at least 1 ablative procedure (RFA and/or Cryotherapy) and are intolerant to the procedure due to pain, where intolerant is defined as post-procedure dysphagia or odynophagia persisting for 24 hours or greater or requiring narcotic analgesia for a duration of more than 24 hours. 3. Residual Barrett's length is ≥1 cm and ≤6 cm. 4. No confirmed evidence of esophageal adenocarcinoma (EAC) at the time of therapy. 5. Subject capable of giving informed consent. 6. Subject has a reasonable expectation for prolonged survival (greater than 2 years). 7. Subject can tolerate repeated endoscopic procedures. 8. Absence of strictures refractory to dilation that preclude the passage of the endoscope 9. Patients who were on acid suppression therapy (i.e. PPIs) during the course of failed primary ablative therapy, and who can continue acid suppression therapy for the entire time they are on the clinical study. 10. Subjects with the ability to understand the requirements of the study, who have provided written informed consent, and who are willing and able to return for the required follow-up assessments through 12 months, as indicated.

Exclusion criteria

1. Subject unable to give informed consent. 2. Subject is unwilling to return for repeated endoscopies. 3. Confirmed endoscopic and or histologic evidence of EAC at time of therapy. 4. Residual Barrett's longer than 6 cm. 5. Subjects with nodular Barrett's esophagus. 6. Subjects who are on anticoagulant therapy that cannot be discontinued for 5 days before and after the procedure. 7. Subjects with known coagulopathy defined as abnormal prothrombin or partial thromboplastin time. 8. History of esophageal varices 9. LA Grade B, C, or D esophagitis. 10. Esophageal stricture refractory to dilation preventing passage of endoscope or catheter. 11. Any previous esophageal surgery, except fundoplication without complications. 12. Medically uncorrectable hypotension or hypertension. 13. Any condition that in the opinion of the investigator would create an unsafe clinical situation that would not allow the patient to safely undergo an endoscopic procedure (lack of medical clearance). 14. Pregnant or lactating women or women of childbearing potential who do not employ a reliable method of contraception as judged by the Investigator, and/or are not willing to use reliable contraception for the duration of study participation. 15. Subject has known severe psychiatric disorder, substance abuse, or other reason for being unable to follow trial follow-up instructions. 16. Patient has a known significant concomitant illness with a life expectancy of less than 2 years. 17. Subject is known to be currently enrolled in another investigational trial that could interfere with the endpoint analyses of this trial.

Design outcomes

Primary

MeasureTime frameDescription
Incidence of complete removal of refractory Barrett's esophagus12 monthsThe primary effectiveness endpoint for this study is the complete removal of refractory Barrett's esophagus in no more than three treatments as assessed by a biopsy negative for Barrett's esophagus at the 12 month follow-up visit.
Rate of device- and procedure-related serious adverse events (SAEs)12 monthsThe primary safety endpoint for this study is the rate of device- and procedure-related serious adverse events (SAEs) for bleeding, perforation, and stricture in the EndoRotor arm will be no greater than that of the continued ablative therapy arm.

Secondary

MeasureTime frameDescription
Activated Fibroblasts12 monthsPercent reduction of activated fibroblasts in the area with Barrett's esophagus that was resected using EndoRotor at initial treatment session through the 12 month follow-up visit as per the histological findings of keyhole technique biopsies. - this point is only assessed in the first 5 EndoRotor subjects
Percent Reduction of Barrett's Esophagus12 monthsPercent reduction of Barrett's esophagus that was resected or ablated during the initial treatment session through the 12 month follow-up visit as calculated using the Prague classification measurements of estimated circumference and maximal length.
Post Procedure Pain9 monthsAssessment of subject post procedure pain as compared to the control arm by means of a visual analogue pain scale. The visual analogue pain scale used for this study allows a patient to record their pain using a scoring system from 0 to 10. Zero representing no pain, 5 representing moderate pain, and 10 representing the worst possible pain. Lower scores represent a better score.

Countries

Sweden, United Kingdom, United States

Contacts

PRINCIPAL_INVESTIGATORKenneth Wang, MD

The Mayo Clinic

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 28, 2026