Electrical Activation Mapping Guided Tailor Made Approach for Cardiac Resynchronization Therapy

Electrical Activation Mapping Guided Tailor Made Approach for Cardiac Resynchronization Therapy

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03356652
Enrollment
93
Registered
2017-11-29
Start date
2018-03-08
Completion date
2024-08-31
Last updated
2021-10-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Keywords

Cardiac resynchronizaton therapy, Electrical activation mapping, Noninvasive, Electrical dyssynchrony

Brief summary

Background Cardiac Resynchronization Therapy (CRT) is proven to improve survival and heart function of patient with certain electrical conduction abnormality and heart failure. However, in patient with certain electrical conduction abnormality, a good response is observed in less than 40% in patient receiving CRT. Conventionally the surgical approach of CRT is to implant one pacing lead in the right heart and one in the left heart to resynchronize the contraction and the pacing lead in the left heart is usually placed in the posterior or lateral portion of the left heart. However, this single approach may not be optimal, especially for those patients with conduction abnormality known to have poor response to CRT. Purpose of the clinical investigation The purpose of the Electrical Activation Guided CRT Study is to study the effectiveness of a tailored made approach to CRT procedure by using a noninvasive globally mapping system studying the electrical conduction under different approaches to delivery CRT. The pacing approach that optimally corrects conduction abnormality will be determined before the actual implantation procedure. Conduct of the Investigation This study will include 93 patients with conduction abnormality that known to have a poor response to CRT from Prince of Wales Hospital, Hong Kong.Subjects will be followed up at 3 months and 6 months visit.

Detailed description

The purpose is to prospectively study the feasibility to optimize configuration of CRT delivery for acute correction of electrical dyssynchrony using a noninvasive mapping of global electrical activation. Study Hypothesis: Tailor-made configuration of CRT delivery is feasible and able to improve responder rate compare to single method of CRT delivery in candidates with known poor response to CRT. Primary outcome measure: Responder rate of greater than 10% of LV end systolic volume reduction in patients undergoing tailor-made approach of CRT delivery at 6 months. The responder rate is to compare with pre-defined level of 40% for single method of CRT delivery namely biventricular pacing with LV lead in coronary sinus. Sample Size: The total required sample size is 93 patients with device implanted.

Interventions

PROCEDURENoninvasive electrical dyssynchrony study

Ventricular activation maps will be acquired simultaneously with hemodynamic measurements using noninvasive mapping system (ECVUE, Medtronic Inc, USA). A thoracic computed tomographic scan will be acquired with the electrodes attached to the patient. Local ventricular activation times will be defined as the onset of the QRS complex or the pacing spike to the maximal negative slope of each unipolar electrogram. Pacing leads will be placed in high right atrium, His-bundle region, right ventricular apex, high septal RV, coronary sinus posterior/lateral branch, coronary sinus anterior branch, lateral and septal region of endocardial LV in order to deliver CRT in 8 different configurations.

Sponsors

Chinese University of Hong Kong
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Adult (aged 18 or above) of both sexes * Ischemic or non-ischemic cause of heart failure * QRS duration \> 120 ms, non -LBBB type of conduction disturbance * NYHA class III or above * Sinus rhythm * Informed consent by the patient * Already received stable dose of guideline directed medical therapy for at least 3 months

Exclusion criteria

* LBBB\* patients * Pregnant women * Participation in another study * Patient with contraindication to left ventricle catheterization by a retrograde aortic approach (eg mechanical aortic valve, severe aortic stenosis and aortic dissection) \*The definitions of LBBB (QRS duration ≥130 ms; QS or rS in lead V1; broad R waves in leads I, aVL, V5, or V6; and absent q waves in leads I, V5, and V6).

Design outcomes

Primary

MeasureTime frameDescription
Responder rate of greater than 10% of LV end systolic volume reduction in patients undergoing tailor-made approach of CRT delivery at 6 months.6 monthsResponder rate of greater than 10% of LV end systolic volume reduction measured by echocardiogram comparing baseline and 6 months post implant in patients undergoing tailor-made approach of CRT delivery. Responder rate of greater than 10% of LV end systolic volume reduction measured by echocardiogram comparing baseline and 6 months post implant in patients undergoing tailor-made approach of CRT delivery. The responder rate is to compare with pre-defined level of 40% for single method of CRT delivery namely biventricular pacing with LV lead in coronary sinus.

Secondary

MeasureTime frameDescription
The hemodynamic responses of different methods of CRT delivery.during procedureThe hemodynamic responses of different methods of CRT delivery. The hemodynamic response will be maximal dp/dt as measured by pressure wire introduced into the left ventricle during the procedure.
Procedure duration of the optimal CRT delivery methodduring procedureProcedure duration of the optimal CRT delivery method as determined by the best improvement in electrical dyssynchrony indices.
Implantation success rate of the optimal CRT delivery methodduring procedureImplantation success rate of the optimal CRT delivery method as determined by the best improvement in electrical dyssynchrony indices.
Cine images (PA, LAO 300, RAO 300) and Chest X ray (PA view)during procedureCine images (PA, LAO 300, RAO 300) and Chest X ray (PA view)
Peri-operative and 6 months follow-up complications rate:Peri-operative and 6 months1. Thromboembolic event 2. Dislodgement and migration of pacing leads 3. Phrenic nerve stimulation 4. Others
Left ventricular systolic and diastolic volume at baseline and 6 months:baseline and 6 monthsEchocardiogram parameter of left ventricular systolic and diastolic volume at baseline and 6 months.
The acute electrical dyssynchrony indices of different methods of CRT delivery.during procedureThe acute electrical dyssynchrony indices of different methods of CRT delivery.
Degree of mitral regurgitation at baseline and 6 months:baseline and 6 monthsEchocardiogram parameter of degree of mitral regurgitation at baseline and 6 months.
Strain imaging at baseline and 6 months:baseline and 6 monthsEchocardiogram parameter of strain imaging at baseline and 6 months.
NYHA classbaseline and 6 monthsNYHA class at baseline and 6 months.
6 minute hall walk testbaseline and 6 months6 minute hall walk test at baseline and 6 months.
Quality of life using Minnesota's questionnairebaseline and 6 monthsQuality of life using Minnesota's questionnaire at baseline and 6 months.
Electrical parameters including threshold, sensitivity and lead impedance of pacing leads at implant and 6 months follow-up.during procedure and 6 monthsElectrical parameters including threshold, sensitivity and lead impedance of pacing leads at implant and 6 months follow-up.
Left ventricular ejection fraction at baseline and 6 months:baseline and 6 monthsEchocardiogram parameter of left ventricular ejection fraction at baseline and 6 months.