Skip to content

Pilot Removal of Palpable Subdermal Contraceptive Rod Implants

A Prospective, Single-centre, Non-comparative Feasibility Investigation to Evaluate Performance and Safety of RemovAid ™ Retrieval Device When Used for Removal of Palpable Subdermal Contraceptive Rod Implants.

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03356119
Acronym
REVALID02
Enrollment
19
Registered
2017-11-29
Start date
2017-12-12
Completion date
2018-09-04
Last updated
2018-10-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Removal of Contraceptive Implant

Keywords

Contraceptive Implant

Brief summary

There are no implant removal devices on the market by any manufacturer. Overall, the RemovAid™ combines the features of fixation, incision and extraction. This combination of functions has not previously been combined in a single device. The investigators wish to perform this pilot clinical investigation with the aim to demonstrate that the Investigational Medical Device (IMD), RemovAid ™, may safely and effectively facilitate implant removal. Other aims are to show that the IMD have the potential to reduce procedure length variability, reduce procedural complexity and reduce the need for additional procedural equipment related to CI removal procedures, without causing any harm to the subject.

Detailed description

Detailed Description: Contraceptive Implants (CIs) were introduced to the commercial market in the early 1980s. They are advocated as a safe and effective method of contraception, and are included on the WHO's Essential Medicines list. CI manufacturers have focused intense efforts on making insertion of CIs easier, but have largely left CI removals untouched and at the mercy of the various service providers. Different introducers and trocars are available for use with the different CI systems available internationally, and a second generation, single-use trocar is supplied with the Nexplanon® implant system available in Sweden. This second generation trocar has reduced the number of misplaced or deeply inserted CIs, and underlines the benefits of standardizing minor surgical procedures through the use of dedicated medical devices. The CI removal procedure recommendations have remained essentially unchanged for 40 years, relying on scalpels, forceps and general surgical skills from the service provider. Currently, no standardized technique for removal of CIs exists, and no dedicated CI removal device is found on the commercial market. Removal of palpable subdermal implants is generally a simple, minor surgical office procedure. However, the procedure for implant removal requires more training and skill than the procedure for insertion. There is a risk of slippage of the scalpel blade or a sudden movement by the client causing inadvertent deeper penetration, in which case any underlying structure could be affected. Mean removal times, from time of incision until removal of the rod, are consistently reported as less than four minutes, however with ranges from 0.2 - 60 minutes. Available research shows that the procedure length of the current CI removal procedure is highly variable and reliant on individual operator skills.

Interventions

DEVICERemovAid device

The contraceptive implants of the subjects in this arm are removed by the new IMD.

Sponsors

Karolinska University Hospital
CollaboratorOTHER
Bill and Melinda Gates Foundation
CollaboratorOTHER
The Research Council of Norway
CollaboratorOTHER
Amano Clinical Consulting AB
CollaboratorOTHER
RemovAid AS
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE

Intervention model description

All recruited subjects will be assigned to implant removal using the RemovAid IMD. There is no formal comparator in this study. The investigators are investigating design functionality and safety.

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Female age 18 or older * Willing to remove a palpable subdermal Implanon/ Nexplanon CI * Willing and able to give written informed consent for participation in the investigation * Willing to provide follow-up information according to the Clinical Investigators brochure

Exclusion criteria

* Known allergy to local anaesthetic (lidocaine/lignocaine) or disinfectant (chlorhexidine). * Active skin lesion over the CI. * The Investigator considers the subject unlikely to comply with investigational procedures, restrictions and requirements. * Any contraindication for removal of the PI, as judged by the Investigator. * Any disorders or medications that might affect coagulation, as judged by the Investigator. * Any conditions suspected to affect healing or increase risk of infection (e.g. keloid tendency, diabetes or any upper arm dermatological condition that may affect upper arm healing)

Design outcomes

Primary

MeasureTime frameDescription
Successful removal of implant .15 minutesPercentage of fixated implants that were successfully removed without the use of additional tools

Secondary

MeasureTime frameDescription
Pain during procedure5 minutesMean pain score (maximum pain intensity during the procedure) indicated by the subject on a Visual Analogue Scale (VAS) 0-100 mm ruler, assuming that anaesthesia has been properly administered.
Success of fixation of implant5 minutesPercentage of palpable implants where the implant could be seen and/or felt on both sides of the clamp after maximum three attempts of fixation
Duration of procedure25 minutesMean time from making incision until implant is removed. first handling the device until closing the wound.
Frequency, severity, causality and outcome of adverse events (AEs)1 weekBoth Anticipated and unanticipated AEs will be recorded, both immediately following the intervention and at follow-up.
Operators impression of the device5 minutesThe operator's global impression of the IMD will be assessed using a 5-point scale, where 5 is excellent
Subject satisfactionTime Frame: 5 minutesThe subject's global assessment of satisfaction with the procedure will be assessed using a 5- point scale, where 5 is excellent
Technical functionality of device determined by an operators questionnaire5 minutesFulfilment of pre-defined technical requirements, as documented on an operator functionality questionnaire. The questionnaire consists of a range of yes/no questions to device functionality

Countries

Sweden

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026