Skip to content

Biomechanical Effects of Wearing a Sacroiliac Belt in Women

A Case-Control Pilot Study on the Biomechanical Effects of Wearing a Sacroiliac Belt in Women

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03334799
Enrollment
10
Registered
2017-11-07
Start date
2015-02-25
Completion date
2017-09-09
Last updated
2017-11-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pelvic Girdle Pain

Keywords

sacroiliac belt, kinematics, stability, pelvic girdle pain, sacroiliac instability

Brief summary

Women with pelvic girdle pain PGP) often get relief from using a sacroiliac belt. The study will explore if there are differences and in the changes of lower body movement in stability with the belt on and with the belt off. Women with PGP will be matched with women without to explore if there is a difference between these two groups. This will be looked at in standing and in walking.

Detailed description

SacroIliac (SI) joint dysfunction (also called pelvic girdle pain) has been associated with impaired load transfer across the lumbopelvic region. This can result in lower back pain as well as poor biomechanical adaptation during walking. Sacroiliac (SI) belts have typically been prescribed in order to mitigate pain and improve load transfer in individuals with SI joint dysfunction. It has been speculated that SI belts have the ability to instantaneously increase joint stability, and as a result improve load transfer and muscle activation and recruitment. However, this speculation is primarily based on anecdotal evidence; there is little biomechanical research supporting the effects of wearing an SI belt. In order to gain an improved understanding of the biomechanical effects of wearing an SI belt, the investigators propose to conduct a study with the following key objectives: 1. Determine if there are differences with respect to neuromuscular, kinematic, or pressure patterns during walking and/or standing between healthy stable individuals and individuals with SI joint dysfunction 2. Determine if wearing an SI belt affects neuromuscular, kinematic, or pressure patterns during walking and/or standing in women with sacroiliac instability Variables measured will include: 1. Kinematics will be collected to quantify posture and joint angles 2. Kinetics will be collected to quantify ground reaction forces 3. Plantar pressure will be collected to quantify force distribution and center or pressure 4. Joint moments (Lumbar-pelvic and Hip) will be added as variables. The investigators will use inverse dynamics to calculate various joint moments during walking.

Interventions

DEVICEsacroiliac belt

standing and walking with the belt on and with the belt off

Sponsors

University of Calgary
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SCREENING
Masking
NONE

Intervention model description

case control

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

* Females * Individuals with isolated SI joint dysfunction * Individuals with shoe size 6, 7, 8 or 9 US and matched controls by age (within 5 years), BMI (within one point) and parity

Exclusion criteria

* Pregnancy in the last year or presently pregnant * Significant lumbar dysfunction * Significant hip dysfunction * Leg length discrepancy of 1 cm or more * Women who have previously undergone prolotherapy or SI joint injections * Women with previous lower back, hip, knee or ankle surgery * Inability to stand for 60 sec unaided or to walk unaided.

Design outcomes

Primary

MeasureTime frameDescription
Explore if 95% confidence ellipse area of the center of pressure or kinematic measures can distinguish women with PGP from women without PGP when a SI belt is appliedwithin 2 months of enrollment, measured at one point in timePressure insoles will be used to quantify the 95% confidence ellipse area of the CoP determined from each of the 2 feet, during the 30 second standing trials. The sampling will be compounded at a rate of 100 Hz and provided a time-pressure series with a range from 15 to 1200 kPa. The 95% confidence ellipse area of both feet will be summed. The average of the 3 trials will be used. Kinematic data will be collected using eight high speed video cameras at a sample rate of 240 Hz. All test subjects will be equipped with a marker set consisting of 32 light reflecting markers according to Visual3D (C-Motion, Inc., Germantown, USA) marker set guidelines. All measurements will be made on the right side. Walking speed will be monitored using photo electronic cells. Identified and averaged for 10 over-ground walking trials for each participant using custom Matlab software (MathWorks Inc., Natick, MA, USA).

Secondary

MeasureTime frameDescription
95% confidence ellipse area of the center of pressurewithin 2 months of enrollment, measured at one point in timePressure insoles (Pedar, novel GmbH, Germany) will be used to quantify the 95% confidence ellipse area of the CoP determined from each of the 2 feet, during the 30 second standing trials. The sampling will be compounded at a rate of 100 Hz and provided a time-pressure series with a range from 15 to 1200 kPa. Prior to testing, the insoles will be calibrated as per the manufacture's protocol. All data will be analyzed using custom Matlab scripts. The 95% confidence ellipse area of both feet will be summed. The average of the 3 trials will be used.Gait variability will be assessed by calculating the average position of the CoP in the medial-lateral direction during walking using pedar pressure insoles. The mean and standard deviation of the average CoP position will be defined as gait variability in medial-lateral direction calculated for each subject, foot, and condition.
kinematic changes of lower extremitywithin 2 months of enrollment, measured at one point in timeA force plate (Kistler Instrumente AG, Switzerland) recording at 2400 Hz will be positioned in the middle of a 15 meter walkway to measure ground reaction forces (GRF) during standing and walking. The threshold for determining heel strike wil be 20 N. Walking speed will be monitored using photo electronic cells (model TC Timing System; Brower Timing Systems, Draper, UT). Discrete kinematic and kinetic variables will be identified and averaged for 10 over-ground walking trials for each participant using custom Matlab software (MathWorks Inc., Natick, MA, USA). Kinematic data will be collected using eight high speed video cameras (Motion Analysis Corporation, Santa Rosa, USA) Version 3.6.1.1315 at a sample rate of 240 Hz. All test subjects will be equipped with a marker set consisting of 32 light reflecting markers according to Visual3D (C-Motion, Inc., Germantown, USA) marker set guidelines. All measurements will be made on the right side.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026