Assessment of Left Atrial Mechanical Function With a True 3D Ultrasouns Arry and Comparison With the Transthoracic and Transesophageal Echocardiography

Assessment of Left Atrial Mechanical Function With a True 3D Ultrasound Array and Comparison With the Transthoracic and Transesophageal Echocardiography: A Single Center Interventional Study in Patients Scheduled for Ablation Procedure

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03331029
Enrollment
100
Registered
2017-11-06
Start date
2017-11-01
Completion date
2019-12-31
Last updated
2019-10-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Comparison of 3D Monitored Changes of Left Atrial Volume Before and After Ablation With Conventional Transesophageal Echocardiography

Keywords

3 D Ultrasound, left atrium, Mitral inflow velocity, systolic and diastolic ventricular function

Brief summary

Chronic atrial fibrillation is a challenging arrhythmia requiring additional radiofrequency ablation besides pulmonary vein isolation. Atrial contractility in these patients is often impaired. Until now mapping catheters were used on virtual geometry maps of left atrium. However, changes in atrial volume cannot be assessed with these systems Assessments of atrial volumes with echocardiography relies on 2D and 3D measurements and modeling. The AcQMapTM 3D High Resolution Imaging and Mapping System (AcQMap) has a unique 3D array of ultrasound crystals, which can measure true 3D dimensions of the heart chamber. For the first time, true atrial volumes can be measured. Changing from atrial fibrillation to sinus rhythm causes changes in atrial volume and might be associated with quantitative systolic and diastolic function of the left ventricle measured with the Transesophageal Echocardiography.

Detailed description

Comparison of true 3D atrial volume changes to TEE and TTE findings as well as atrial pressure curves during left heart catheterization. Changing from atrial fibrillation to sinus rhythm causes changes in atrial volume and might be associated with quantitative systolic and diastolic function of the left ventricle measured with the Transesophageal Echocardiography Measurement of true left atrial ejection fraction and comparison to 2D echocardiographic parameters such as transesophageal measured flow velocity of the mitral inflow tract, pulmonary vein flow, the left atrial appendage flow Inclusion: Patients undergoing electrophysiological study with the AcQmap System Age ≥18 years and signed informed consent German speaking Exclusion: Mechanical mitral valve Contraindication for left atrial ablation procedure such as: Intra-cardiac clot, Pregnancy Data collection of ultrasound dimensions of left atrium, left atrial pressure and TEE is performed simultaneously under the following conditions: 1. Fixed heart rate by atrial pacing 2. Apnea initiated at the end of expiration (apnea endexp) 3. With and without complete atrioventricular bloc Under these conditions pressure volume loops are monitored. Simultaneously mitral annulus velocity (septal and lateral), pulmonary vein flow, left atrial appendage flow (max. A and V velocity) and LAA volume (average of 4 planes) are measured The AcQMap Catheter consists of 6 splines with 48 electrodes and ultrasound crystals, which form a true 3D array of about 2 cm diameter. The catheter can be collapsed for introduction over a sheet into the right or left atrium and is used to record electrical bio potentials of the atrium. Besides each electrode is an ultrasound crystal, which measures the distance to the atrial wall at a sample rate 100000/min a ultrasound based anatomy of the atrium is constructed. The procedure of introduction the AcQMap catheter is in the right or left atrium is the same as it is performed with the standard devices for mapping and treating the atrial fibrillation in humans. Analysis of changes in the collected data before and after ablation procedure is performed using unpaired t-test and non-parametric interrogation (Wilcoxon and Mann-Whithey U test) where otherwise appropriate (spss v 16, SPSS Chicago, IL, USA). Normal distributed date will be presented as mean ±SD and 95% confidence interval (CI95) and not normal distributed data will be presented as median and interquartile range (ICR). For repeated measures ANOVA will be used to estimate between-subject's variation and within-subject variation.

Interventions

DEVICEtransesophageal investigation

Comparison of 3D ultrasound with transesophageal echocardiography

Sponsors

Klinik Hirslanden, Zurich
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
BASIC_SCIENCE
Masking
NONE

Intervention model description

Single Center interventional study

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* Patients undergoing electrophysiological study with the AcQmap System * Age ≥18 years and signed informed consent * German speaking

Exclusion criteria

* Mechanical mitral valve * Contraindication for left atrial ablation procedure such as: Intra-cardiac clot, * Pregnancy

Design outcomes

Primary

MeasureTime frame
Changes in Mitral flow velocity1 hour
changes in pulmonary vein flow1 hour
changes in left atrial appendage flow1 hour

Countries

Switzerland

Contacts

Primary ContactWerner Baulig, MD
werner.baulig@hirslanden.ch+41 44 209 28 75
Backup ContactChristoph Scharf, MD
christoph.scharf@hirslanden.ch+41 44 209 29 00