Skip to content

Single Arm Study Using the Symphony -- MRI Guided Focused Ultrasound System for the Treatment of Leiomyomas

MRI-guided High Intensity Focused Ultrasound Ablation of Leiomyomas. Single Arm, Feasibility Study Using the Symphony - MRI Guided Focused Ultrasound System for the Treatment of Leiomyomas

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03323905
Acronym
HIFUSB
Enrollment
50
Registered
2017-10-27
Start date
2017-11-16
Completion date
2024-03-03
Last updated
2024-07-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fibroid, Leiomyoma

Brief summary

Single arm, first-in human feasibility study using the Symphony - MRI guided focused ultrasound system for the treatment of leiomyomas. The study is expected to accrue over 12 months. This study will help determine the feasibility to ablate leiomyomas, as measured by MR thermometry and contrast enhanced imaging. In addition, the study will look at the efficacy and safety of the treatment, as measured by the reduction in fibroid size and reduction in symptom severity score and adverse events. This study will help develop future pivotal trials using the same device.

Interventions

DEVICESymphony MRI guided High Intensity Focused Ultrasound (HIFU)

The use of the MRI-HIFU for the ablation of leiomyomas

Sponsors

Sunnybrook Research Institute
CollaboratorOTHER
Arrayus Technologies Inc.
CollaboratorINDUSTRY
Sunnybrook Health Sciences Centre
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Pilot single arm feasibility trial.

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. MR-HFU device accessibility to fibroids that at least 50% of fibroid volume can be treated 2. Fibroids selected for treatment meet the following criteria 1. Total planned ablation volume of all fibroids should not exceed 500 ml AND 2. Completely non-enhancing fibroids should not be treated 3. Transformed SSS score \>= 40 4. Pre- or peri-menopausal, as indicated by clinical evaluation 5. Weight \< 140 kg or 310 lbs 6. Willing and able to attend all study visits 7. Willing and able to use reliable contraception methods 8. Uterine size \< 24 weeks 9. Cervical cell assessment by PAP: normal, LOW Grade SIL, Low risk HPV or ASCUS subtypes of cervical tissue 10. Waist circumference \<110cm or 43 inches

Exclusion criteria

1. Other Pelvic Disease (Other mass, endometriosis, ovarian tumor, acute pelvic disease, significant adenomyosis, prolonged bleeding requiring further evaluation as determined by patient's gynecologist) 2. Positive pregnancy test 3. Extensive scarring along anterior lower - abdominal wall (\>50% of area) 4. Surgical clips in the potential path of the HIFU beam 5. Tattoos in the potential path of the HIFU beam 6. MRI contraindicated 7. MRI contrast agent contraindicated (including renal insufficiency) 8. Calcification around or throughout uterine tissue that may affect treatment 9. Communication barrier 10. Fibroids not quantifiable on MRI (e.g., multi-fibroid cases where volume measurements are not feasible) 11. Pedunculated fibroids 12. Bowel loops int he ultrasound beam path 13. Patients with inability to tolerate prolonged prone position for up to 3 hours 14. Patient with unstable medical conditions 15. Patients with coagulopathy or under current anti-coagulation therapy

Design outcomes

Primary

MeasureTime frameDescription
The ability to ablate fibroid tissue measured by temperature elevation1 yearMeasured by MRI thermometry
The ability to ablate fibroid tissue indicated by Non-Perfused Volume (NPV)1 yearMeasure by contrast enhanced imaging
Safety of the system measured by collection of adverse events related to potential damage to tissue outside the treatment zone1 yearSafety will be measured by collection of adverse events related to potential damage to tissue outside the treatment zone.
Safety of the system based on damage to skin measured by collection of adverse events related to potential damage to skin over the treatment volume1 yearSafety will be measured by collection of adverse events related to potential damage to skin over the treatment volume.

Secondary

MeasureTime frameDescription
Treatment efficacy to reduce fibroid size by NPV1 yearMeasured by non-perfused volume in milliliters
Treatment efficacy to reduce symptom severity by Symptom Severity Scores (SSS)1 yearChange in symptoms to be quantified by Symptom Severity Scores (SSS) derived from Uterine Fibroid Symptom and Quality of Life questionnaire.
Treatment efficacy to reduce fibroid size1 yearReduction of fibroid volume in milliliters

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 24, 2026