Skip to content

Neuraxial Anaesthesia: Does BMI Relate to Ease of Neuraxial Anaesthesia?

Neuraxial Anaesthesia: Does BMI Relate to Palpability of Bony Landmarks and Are Standard Needles a Suitable First Choice in Patients With BMI>30kg/m2

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03315845
Enrollment
100
Registered
2017-10-20
Start date
2017-10-23
Completion date
2018-01-09
Last updated
2017-10-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Neuraxial Ultrasound, Obesity, Obstetric Anaesthesia

Keywords

BMI, obstetric anaesthesia, neuraxial anaesthesia, neuraxial ultrasound, difficult neuraxial anaesthesia

Brief summary

Neuraxial anaesthesia can be more difficult and associated with more complications if the patient's bony landmarks are difficult to palpate. They are more likely to be difficult to palpate if a patient has a high Body Mass Index (BMI), (\>30kg/m2). The depth that the spinal or epidural needle must be inserted is usually longer in these patients with high BMIs. We wish to palpate the backs of at least 100 such patients to see how many of them have impalpable bony landmarks. We then wish to use ultrasound to measure the distance from skin to the posterior epidural complex to discover if this length is longer than the standard needle length. If it is longer in the majority of people we study, we will recommend changing standard practice to start using a longer needle for all first attempts at neuraxial anaesthesia in this patient population.

Detailed description

Complications rates including failure are higher in obese patients undergoing anaesthesia procedures. Anaesthetists have adopted the use of ultrasound to assist in overcoming these difficulties. Neuraxial ultrasound is proving to be beneficial in those patients in whom identification of interspinous spaces is difficult and most of these patients are obese. In our institution, there is a 'standard practice' for neuraxial procedures, with a 'standard' needle used for first attempts (Whitacre 25G 90mm for spinal, Tuohy 18G 80mm for epidural). If the operator has not reached the desired space (spinal or epidural) with the needle inserted to 8cm, a longer needle is then considered for further attempts. This exposes the patient to at least one extra neuraxial needle insertion. Studies have shown that increased needle insertions and redirections are associated with increased complications. We hypothesised that a large number of patients with BMI\>30kg/m2 would have a depth of spinal/epidural space that is greater than the length of the 'standard' needle used. Therefore we suggest that practice should change to use the longer needle or a combined spinal-epidural on the first attempt in these patients. To test our hypothesis, we will assess the ease of palpation of the following anatomical landmarks: anterior and posterior iliac crests; lumbar spinous processes; scapulae; and sacral cornua. We will then perform neuraxial sonography of the lumbar spine, measuring depth to epidural space. Finally we will measure waist circumference in those patients with BMI \<30kg/m2.

Interventions

OTHERPalpation of bony landmarks for neuraxial anaesthesia.

Manual palpation of anterior and posterior iliac crests; lumbar spinous processes; scapulae; and sacral cornua. Ultrasound of neuraxial anatomy to assess depth to epidural space.

Sponsors

National Maternity Hospital, Ireland
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
16 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Recorded BMI \>30kg/m2; ability to give consent; non-emergency cases.

Exclusion criteria

* Previous metal work to lumbar spine.

Design outcomes

Primary

MeasureTime frameDescription
Palpability of bony landmarks for neuraxial anaesthesia4 monthsThe percentage of patients with BMI\>30kg/m2 who have difficult or impalpable bony landmarks including: lumbar spinous processes; anterior and posterior iliac spines; scapulae; and sacral cornua.

Secondary

MeasureTime frameDescription
Ultrasonographic distance from skin to posterior epidural complex4 monthsTo use sonography to measure the distance from skin to the dural complex in these patients and quantify the percentage whose distance is greater than the length of the standard needle.

Contacts

Primary ContactMoninne Creaney, MBBChBAOFCAI
creaneym@hotmail.com00353879837656

Outcome results

None listed