Skip to content

Effect of Mechanical Ventilation on Plasma Concentration Level of R-spondin Proteins

the Change of R-spondin Proteins Plasma Concentration Level Caused by Mechanical Ventilation and Its Effect on Mechanical Ventilation Induced Lung Injury

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03315702
Enrollment
52
Registered
2017-10-20
Start date
2017-09-22
Completion date
2017-10-31
Last updated
2019-07-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Lung Injury

Keywords

R-spondin proteins, mechanical ventilation, lung injury

Brief summary

As novel agonists of Wnt/β-catenin signaling pathway, R-spondin proteins constitute a class of ligands, including R-spondin 1/2/3/4, functioning through their receptors leucine-rich repeat-containing G-protein coupled receptor (LGR)4/5/6 to enhance Wnt/β-catenin activity. Since Wnt signaling plays pivotal roles in the regulation of many life processes involved in embryogenesis and adulthood, R-spondin proteins also take part in cell proliferation, differentiation and morphogenesis.For example, in the formation of respiratory system,R-spondin 2 is required for normal laryngeal-tracheal and lung morphogenesis,and the lack of R-spondin 1 expression results in the absence of duct side-branching development and subsequent alveolar formation. In addition, R-spondins show protective effect in tissue injury and diseases. R-spondin 1 and R-spondin 3 have been reported to prevent chemotherapy- or radiotherapy-induced mucous membrane lesion. R-spondin 1 attenuates oral mucositis contributed by radiotherapy in mouse models and R-spondin 3 potentiates intestinal regeneration elicited via gastrointestinal toxic effect of chemoradiotherapy treatment. However, whether R-spondin proteins exert salient influence on acute lung injury especially induced by mechanical ventilation is deficient. Therefore, this study aims to ascertain the implication of R-spondin proteins in the pathology of mechanical ventilation induced lung injury through detecting human plasma concentration change of R-spondin 1/2/3/4 after mechanical ventilation and interference effects in mouse model, which is helpful for prevention and treatment of ventilation induced lung injury.

Detailed description

Mechanical ventilation is a critical intervention for patients with acute respiratory failure. However, lung overdistension induced by mechanical ventilation also causes pulmonary endothelial dysfunction. The injurious effect of mechanical stretch on pulmonary endothelium has been implicated in the development of ventilator-induced lung injury, which is characterized by pulmonary inflammation and particularly increased vascular permeability. In addition, the investigators and others have previously shown that mechanical stretch increases cultured lung endothelial monolayer permeability in vitro and promotes lung vascular permeability in mice Thus, elucidating the mechanisms underlying the mechanical stretch-induced lung endothelial barrier dysfunction may provide a novel clinical therapeutic target against ventilator-induced lung injury. As novel agonists of Wnt/β-catenin signaling pathway, R-spondin proteins constitute a class of ligands, including R-spondin 1/2/3/4, functioning through their receptors leucine-rich repeat-containing G-protein coupled receptor (LGR)4/5/6 to enhance Wnt/β-catenin activity. Since Wnt signaling plays pivotal roles in the regulation of many life processes involved in embryogenesis and adulthood, R-spondin proteins also take part in cell proliferation, differentiation and morphogenesis. For example, in the formation of respiratory system,R-spondin 2 is required for normal laryngeal-tracheal and lung morphogenesis,and the lack of R-spondin 1 expression results in the absence of duct side-branching development and subsequent alveolar formation. In addition, R-spondins show protective effect in tissue injury and diseases. R-spondin 1 and R-spondin 3 have been reported to prevent chemotherapy- or radiotherapy-induced mucous membrane lesion. R-spondin 1 attenuates oral mucositis contributed by radiotherapy in mouse models and R-spondin 3 potentiates intestinal regeneration elicited via gastrointestinal toxic effect of chemoradiotherapy treatment. However, whether R-spondin proteins exert salient influence on acute lung injury especially induced by mechanical ventilation is deficient. Therefore, this study aims to ascertain the implication of R-spondin proteins in the pathology of mechanical ventilation induced lung injury through detecting human plasma concentration change of R-spondin 1/2/3/4 after mechanical ventilation and interference effects in mouse model, which is helpful for prevention and treatment of ventilation induced lung injury.

Interventions

OTHERmechanical ventilation

mechanical ventilation protocol: tidal volume 6-8 ml/kg, positive end-expiratory pressure 5 cm H2O, oxygen concentration 40%; respiratory rate 10-15/min, inspiratory/expiratory ratio 1:1.5.

Sponsors

Xinhua Hospital, Shanghai Jiao Tong University School of Medicine
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* undergo elective surgery with mechanical ventilation lasting for \> 3 hours; classified as physical status I to III according to the American Society of Anesthesiologists Physical Status Classification System; Written informed consent is approved.

Exclusion criteria

* chronic lung disease; recent lung infection; recent anaesthetics or mechanical ventilation treatment; hemodilution with massive fluid supply during surgery; children;women during pregnancy or lactation; being involved in other clinical subjects

Design outcomes

Primary

MeasureTime frameDescription
Change in Plasma Concentration of R-spondin 13 hoursThe venous blood samples were collected twice for each patient that the first time was around the onset of the mechanical ventilation and the second was 3rd hour after the onset of the mechanical ventilation, which were named as sample A and sample B relatively. Then, plasmids were separated by centrifugation and detected for R-spondin1 concentration. And the outcome was calculated by subtracting the R-spondin1 plasmid concentration of sample A from the R-spondin1 plasmid concentration of sample B, which was the change in plasma concentration of R-spondin1.
Change in Plasma Concentration of R-spondin 23 hoursThe venous blood samples were collected twice for each patient that the first time was around the onset of the mechanical ventilation and the second was 3rd hour after the onset of the mechanical ventilation, which were named as sample A and sample B relatively. Then, plasmids were separated by centrifugation and detected for R-spondin2 concentration. And the outcome was calculated by subtracting the R-spondin2 plasmid concentration of sample A from the R-spondin2 plasmid concentration of sample B, which was the change in plasma concentration of R-spondin2.
Change in Plasma Concentration of R-spondin33 hoursThe venous blood samples were collected twice for each patient that the first time was around the onset of the mechanical ventilation and the second was 3rd hour after the onset of the mechanical ventilation, which were named as sample A and sample B relatively. Then, plasmids were separated by centrifugation and detected for R-spondin3 concentration. And the outcome was calculated by subtracting the R-spondin3 plasmid concentration of sample A from the R-spondin3 plasmid concentration of sample B, which was the change in plasma concentration of R-spondin3.
Change in Plasma Concentration of R-spondin43 hoursThe venous blood samples were collected twice for each patient that the first time was around the onset of the mechanical ventilation and the second was 3rd hour after the onset of the mechanical ventilation, which were named as sample A and sample B relatively. Then, plasmids were separated by centrifugation and detected for R-spondin4 concentration. And the outcome was calculated by subtracting the R-spondin4 plasmid concentration of sample A from the R-spondin4 plasmid concentration of sample B, which was the change in plasma concentration of R-spondin4.

Countries

China

Participant flow

Participants by arm

ArmCount
Control/Mechanical Ventilation
venous blood samples collected from patients twice,relatively before mechanical ventilation and 3rd hour after mechanical ventilation mechanical ventilation: mechanical ventilation protocol: tidal volume 6-8 ml/kg, positive end-expiratory pressure 5 cm h2o, oxygen concentration 40%; respiratory rate 10-15/min, inspiratory/expiratory ratio 1:1.5.
52
Total52

Baseline characteristics

CharacteristicControl/Mechanical Ventilation
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
0 Participants
Age, Categorical
Between 18 and 65 years
52 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
52 Participants
Race (NIH/OMB)
Black or African American
0 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
0 Participants
Region of Enrollment
China
52 participants
Sex: Female, Male
Female
14 Participants
Sex: Female, Male
Male
38 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 52
other
Total, other adverse events
0 / 52
serious
Total, serious adverse events
0 / 52

Outcome results

Primary

Change in Plasma Concentration of R-spondin 1

The venous blood samples were collected twice for each patient that the first time was around the onset of the mechanical ventilation and the second was 3rd hour after the onset of the mechanical ventilation, which were named as sample A and sample B relatively. Then, plasmids were separated by centrifugation and detected for R-spondin1 concentration. And the outcome was calculated by subtracting the R-spondin1 plasmid concentration of sample A from the R-spondin1 plasmid concentration of sample B, which was the change in plasma concentration of R-spondin1.

Time frame: 3 hours

ArmMeasureValue (MEAN)Dispersion
Control/Mechanical VentilationChange in Plasma Concentration of R-spondin 11407.4080 pg/mlStandard Deviation 1350.7859
Primary

Change in Plasma Concentration of R-spondin 2

The venous blood samples were collected twice for each patient that the first time was around the onset of the mechanical ventilation and the second was 3rd hour after the onset of the mechanical ventilation, which were named as sample A and sample B relatively. Then, plasmids were separated by centrifugation and detected for R-spondin2 concentration. And the outcome was calculated by subtracting the R-spondin2 plasmid concentration of sample A from the R-spondin2 plasmid concentration of sample B, which was the change in plasma concentration of R-spondin2.

Time frame: 3 hours

ArmMeasureValue (MEAN)Dispersion
Control/Mechanical VentilationChange in Plasma Concentration of R-spondin 2-2.1830 pg/mlStandard Deviation 35.3601
Primary

Change in Plasma Concentration of R-spondin3

The venous blood samples were collected twice for each patient that the first time was around the onset of the mechanical ventilation and the second was 3rd hour after the onset of the mechanical ventilation, which were named as sample A and sample B relatively. Then, plasmids were separated by centrifugation and detected for R-spondin3 concentration. And the outcome was calculated by subtracting the R-spondin3 plasmid concentration of sample A from the R-spondin3 plasmid concentration of sample B, which was the change in plasma concentration of R-spondin3.

Time frame: 3 hours

ArmMeasureValue (MEAN)Dispersion
Control/Mechanical VentilationChange in Plasma Concentration of R-spondin3-2.8956 pg/mlStandard Deviation 30.2781
Primary

Change in Plasma Concentration of R-spondin4

The venous blood samples were collected twice for each patient that the first time was around the onset of the mechanical ventilation and the second was 3rd hour after the onset of the mechanical ventilation, which were named as sample A and sample B relatively. Then, plasmids were separated by centrifugation and detected for R-spondin4 concentration. And the outcome was calculated by subtracting the R-spondin4 plasmid concentration of sample A from the R-spondin4 plasmid concentration of sample B, which was the change in plasma concentration of R-spondin4.

Time frame: 3 hours

ArmMeasureValue (MEAN)Dispersion
Control/Mechanical VentilationChange in Plasma Concentration of R-spondin4-269.8598 pg/mlStandard Deviation 1230.6612

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026