Skip to content

Detecting PNES With Single-channel sEMG

Detecting PNES With Single-channel sEMG

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03313362
Enrollment
71
Registered
2017-10-18
Start date
2017-11-03
Completion date
2020-02-29
Last updated
2019-12-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Epilepsy, Motor Partial, Psychogenic Seizures

Brief summary

This is a prospective, comparative, multicenter study of subjects being admitted for standard of care therapy in Epilepsy Monitoring Units in the Veteran's Affair (VA) Medical Centers.

Interventions

Seizure Monitoring and Alerting System

DEVICEvideo EEG

The Video EEG Monitoring Test (VEEG) is a high specialized form of an EEG test in where the patient is continuosly monitored by using a video recorder. This allows doctors to observe brainwaves activity during the time a seizure or spell is occurring.

Sponsors

Brain Sentinel
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
22 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

1. Subject has a history of suspected epileptic seizures with upper extremity motor involvement, or PNES with upper extremity motor involvement. 2. Is being admitted to a hospital for routine vEEG monitoring related to seizures. 3. Male or Female between the ages 22 to 99. 4. If female and of childbearing potential, has a negative pregnancy test and must not be nursing. 5. Can understand and sign written informed consent, or will have a parent or a legally authorized representative (LAR) who can do so, prior to the performance of any study assessments. 6. Subject and/or Primary Caregiver must be competent to follow all study procedures. 7. Subject/LAR consents to the use of vEEG files, including video/audio recordings, for purposes of this research study.

Exclusion criteria

* Intracranial EEG electrodes are being used.

Design outcomes

Primary

MeasureTime frameDescription
Test an independent group of epileptologist's ability to classify motor events between epileptic or non-epileptic using sEMG and audio.1 yearTo test the null hypothesis that three independent epileptologists categorize, by majority vote, epileptic seizures and psychogenic non-epileptic seizures (identified utilizing vEEG review) correctly in no more than 70% of cases using sEMG and audio. We aim to test the null hypothesis that the epileptologists categorize epileptic seizures and psychogenic non-epileptic seizures correctly in no more than 70% of cases. The observed rate of correct classification will be compared to the rate of 70% under the null hypothesis using a two-sided binomial exact test.

Secondary

MeasureTime frameDescription
To test the Brain Sentinel® Seizure Monitoring and Alerting System's ability to classify motor events as epileptic or non-epileptic.1 YearTest the null hypothesis that the Brain Sentinel® Seizure Monitoring and Alerting System categorizes epileptic seizures and psychogenic non-epileptic seizures (identified utilizing vEEG review) correctly in no more than 70% of cases. We aim to test the null hypothesis that the Brain Sentinel® Seizure Monitoring and Alerting System's software categorizes epileptic seizures and psychogenic Nonepileptic seizures correctly in no more than 70% of cases. The observed rate of correct classification will be compared to the rate of 70% under the null hypothesis using a two-sided binomial exact test.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026