Brief summary

Flow disruption is a new endovascular approach for treatment of both ruptured and unruptured intracranial aneurysms, which involves placement of an endosaccular device (WEB) which modifies the blood flow at the level of the neck and induces intraaneurysmal thrombosis. The WEB was designed to treat wide-neck bifurcation aneurysms. This observational study will collect data about the routine practice in one center of using the WEB in ruptured and unruptured intracranial aneurysms. The primary objective is to evaluate its efficacy by assessing the anatomic outcome during follow-up.

Interventions

The WEB aneurysm embolization system is a class III device and consists of an implantable embolization device attached to a delivery device. The WEB is a mesh composed of single layers of braided nitinol tubes with platinum cores. The braids are held together by proximal and distal platinum/iridium radiopaque markers.

Sponsors

Archer Research
CollaboratorINDUSTRY
Medical Therapy Solutions
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Patient is between 18 and 80 years old. * Patient must sign and date the informed consent form \<72hrs post-procedure and prior to data registration. If patient is not able to give informed consent for himself/herself, a legally authorized representative must give informed consent on his/her behalf. * Patient has a ruptured (Hunt and Hess grades 1, 2 or 3) or unruptured intracranial aneurysm requiring endovascular treatment. * Aneurysm with dome-to-neck ratio ≥ 1.

Exclusion criteria

* Aneurysm size unfavourable for WEB implantation (aneurysm width \> 10 mm or aneurysm width \< 3mm). * Patient with Hunt and Hess grades 4 or 5. * Known to be, or suspected of being unable to comply with the study protocol (e.g. no permanent address, known to be non-compliant or presenting an unstable psychiatric history). * Parent vessel occlusion.

Design outcomes

Primary

MeasureTime frameDescription
Determination of anatomic outcome: grade of occlusion of the aneurysm assessed by MRAat 6 months follow-upWEB Occlusion Scale: WOS A: complete occlusion WOS B: complete occlusion with opacification of the proximal recess WOS C: residual neck filling WOS D: residual aneurysm filling

Secondary

MeasureTime frameDescription
Recording the use of additional devices during treatment to occlude the aneurysmDuring index-procedurePossible additional devices are stent, coils, flow diverter
Determination of the occurrence of post-procedural symptomatic thromboembolic eventsup to 24 months follow-up
Determination of clinical outcome: assessing disability of the patient by the modified Rankin Scale (mRS)at 6 to 8 weeks follow-up0 - No symptoms. 1. \- No significant disability. Able to carry out all usual activities, despite some symptoms. 2. \- Slight disability. Able to look after own affairs without assistance, but unable to carry out all previous activities. 3. \- Moderate disability. Requires some help, but able to walk unassisted. 4. \- Moderately severe disability. Unable to attend to own bodily needs without assistance, and unable to walk unassisted. 5. \- Severe disability. Requires constant nursing care and attention, bedridden, incontinent. 6. \- Dead.
Determination of the technical success of the device defined as device deployment in the target aneurysm as intended by the investigator with complete apposition against the aneurysm wall.During index-procedure
Determination of procedural complications (Adverse events) during the operationDuring index-procedureProcedural complications: aneurysm rupture, dissection, thromboembolic events (symptomatic and non-symptomatic), device protrusion through the neck of the aneurysm inside the parent artery, detachment problem, device stuck in microcatheter, bleeding.
Determination of overall mortalityup to 24 months
Recording of intracranial haemorrhage during follow-upup to 24 months
Need for repeat treatment during follow-upup to 24 months
Determination of 30 day mortalityup to 30 days

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026