Skip to content

Arrhythmia Burden, Risk of Sudden Cardiac Death and Stroke in Patients With Fabry Disease

Arrhythmia Burden, Risk of Sudden Cardiac Death and Stroke in Patients With Fabry Disease: the Role of Implantable Loop Recorders

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03305250
Acronym
RaILRoAD
Enrollment
169
Registered
2017-10-09
Start date
2019-09-18
Completion date
2027-07-31
Last updated
2025-05-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fabry Disease

Brief summary

Fabry disease (FD) is a genetic disorder that leads to progressive accumulation of fat or 'sphingolipid' within the tissues, including the heart muscle and conductive tissue. Improvements in the detection of FD, together with more organised clinical services for rare diseases, has led to a rapid growth in the disease prevalence. Earlier and more frequent diagnosis of asymptomatic individuals before development of the disease itself has focused attention on early detection of organ involvement and closer monitoring of disease progression. Moreover, the introduction of enzyme replacement therapy within the last two decades has changed the natural history of FD as follows: a) increased life expectancy; b) improved morbidity; c) modification of the main cause of morbidity and mortality from renal (kidney) to cardiovascular (heart) events, including heart failure, abnormal heart rhythms, stroke and sudden death. Although symptoms such as palpitations and blackouts are extremely common, information on the frequency of proven abnormal heart rhythms is limited. In addition, the rate and appropriateness of implantation of life-saving devices is very variable, including pacemakers to boost the heart when too slow and cardio-defibrillators that stop the heart when too fast. The main markers of risk in similar diseases such as hypertrophic cardiomyopathy cannot be used in FD. While patients are routinely followed up in clinic with heart tracings and echocardiography (ultrasound of the heart), a recent small study has emphasised that these tests under-estimate the burden of abnormal heart rhythms in patients with advanced FD. The use of continuous heart monitoring with an implantable loop recorder (ILR) has led to a significant change in treatment in 13 out of 15 of FD patients. The investigators believe that more frequent use of ILRs will identify a greater need for change in therapy in many more patients than currently treated, with the aim of reducing morbidity and mortality in this patient cohort. In addition this will provide valuable data to inform an estimate of future risk for these patients.

Detailed description

This is a 3-year open-label multicentre randomised controlled trial assessing arrhythmia burden in patients with Fabry cardiac disease. This is an observational study, but with implantable loop recorder (ILR) insertion at recruitment and removal at end of trial for the intervention arm. Null hypothesis: There will be no difference in the identification of arrhythmia between patients following standard care compared to patients following standard care but with the addition of ILR monitoring. Beyond the proposed hypothesis, data collected will be used to inform whether ILR in FD will: 1. Reveal a high burden of unrecognised arrhythmia 2. Lead to frequent treatment modification (anti-coagulation, pacemaker and ICD implantation, ablation) 3. Enable the development of FD specific risk prediction algorithms 4. Identify predictive power of new (Troponin, BNP, lysoGB3, T1 and T2 mapping) and traditional biomarkers

Interventions

DEVICEImplantable Loop Recorder

An implantable loop recorder (ILR), also known as an insertable cardiac monitor, is a small device (smaller than a AAA battery) that is inserted under the skin on the front of the chest. The ILR is inserted using local anesthetic as an out-patient procedure and lasts approximately 30 minutes. The ILR captures a continuous ECG of your heart activity, which allows doctors to detect any abnormal heart rhythms at any point. If you have the ILR, you will have the device for 3 years, after which it will be removed under local anesthetic during an out-patient procedure, again lasting approximately 30 minutes. The ILR device is completely safe and shouldn't affect your day to day living.

Sponsors

Royal Free Hospital NHS Foundation Trust
CollaboratorOTHER
Northern Care Alliance NHS Foundation Trust
CollaboratorOTHER
University of Sydney
CollaboratorOTHER
Cambridge University Hospitals NHS Foundation Trust
CollaboratorOTHER
Cardiff and Vale University Health Board
CollaboratorOTHER_GOV
Sheffield Teaching Hospitals NHS Foundation Trust
CollaboratorOTHER
University Hospital Birmingham NHS Foundation Trust
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with genotypically or enzymatically confirmed FD * Adults \> 18 years of age * Evidence of cardiac involvement from FD involving either: * Any ECG abnormality associated with FD * Low T1 on CMR (below centre-specific normal range according to sex) * LVH on transthoracic echo (defined as MWT \>12mm)

Exclusion criteria

* Patient with an existing cardiac device (PPM, ICD or ILR). * Known dual pathology: * Known coronary artery disease (positive non-invasive imaging, confirmed myocardial infarction, percutaneous or surgical revascularisation). Patients \>40 years old with symptoms that could be from coronary artery disease will have this excluded * Known cardiomyopathy disease causing mutation (e.g. SCN5, MYBPC3)

Design outcomes

Primary

MeasureTime frameDescription
First occurrence of non-sustained ventricular tachyarrhythmia requiring drug treatment, ICD implantation or ablationTotal monitoring time period in study - 3 yearsThis is classified as three or more ventricular beats at a rate \>120bpm, for a duration of less than 30 seconds.
First occurrence of atrial fibrillation (AF) requiring anticoagulationTotal monitoring time period in study - 3 yearsThis will include all descriptions of AF, which can be defined as: 1. paroxysmal - self-terminating episodes lasting between 48 hours to 7 days 2. persistent - intermittent episodes lasting between 7 days to 1 year 3. permanent - episodes lasting longer than 1 year
First occurrence of bradyarrhythmia requiring cardiac pacingTotal monitoring time period in study - 3 yearsThis would include: 1. Symptomatic significant AV block. 2. Mobitz type 2 AV block or complete heart block irrespective of symptoms.
First occurrence of supraventricular arrhythmia requiring drug treatment or ablation.Total monitoring time period in study - 3 years

Secondary

MeasureTime frameDescription
Frequency of arrhythmia in patients with and without late gadolinium enhancement (LGE)3 yearsThe study will aim at quantifying the extent of LGE deposited with myocardial tissue on cardiac MRI scanning. This will subsequently be correlated with the burden of arrhythmia detected to assess for potential risk factors.
Frequency of arrhythmia according to location of myocardial fibrosis (inferolateral vs. non-inferolateral)3 yearsThe study will aim to correlate the location of myocardial fibrosis with the presence or absence of cardiac arrhythmia to define location of fibrosis as a potential risk factor for arrhythmia.
Frequency of arrhythmia in those patients with a QRS duration greater or less than 120ms3 years
Frequency of arrhythmia in those with an atrial size above or below indexed normal range for age and sex3 years

Countries

Australia, United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 21, 2026