Skip to content

Clinical Trial Evaluation of the Percutaneous 4Tech TriCinch Coil Tricuspid Valve Repair System

Clinical Trial Evaluation of the Percutaneous 4Tech TriCinch Coil Tricuspid Valve Repair System

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03294200
Enrollment
18
Registered
2017-09-26
Start date
2017-08-28
Completion date
2020-07-14
Last updated
2020-07-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tricuspid Regurgitation

Brief summary

The objective of the study is to generate safety and performance data for the 4Tech TriCinch Coil System in symptomatic patients suffering from significant functional tricuspid regurgitation with annular dilatation. The TriCinch Coil System is a percutaneous catheter-based medical device for tricuspid valve repair.

Interventions

Patients enrolled in this study with all eligibility criteria confirmed will be implanted with the TriCinch Coil System. This device offers a percutaneous treatment (access through the vein at the groin) to treat the leaking tricuspid valve, without the need for surgical intervention.

Sponsors

4Tech Cardio Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Moderate to severe functional tricuspid regurgitation (TR) defined as: TR severity 2+ to 4+ (according to semi-quantitative echocardiographic color flow doppler evaluation); and Annular diameter ≥ 40 mm confirmed by echocardiography 2. ≥ 18 years old 3. Subject has read and signed the informed consent prior to study related procedures. 4. Willing and able to comply with all required follow-up evaluations and assessments. 5. The 'Heart Team' assessment recommends TriCinch Coil Implantation 6. New York Heart Associate Classification ≥ II. 7. Left Ventricular Ejection Fraction ≥ 30%. 8. Heart failure symptoms (such as fluid retention and severe oedema, liver stasis) despite on optimized medical therapy by the local heart team; at minimum subject on diuretic use 9. Subject has suitable anatomy for investigational device implantation as per imaging requirements

Exclusion criteria

1. Currently participating in another investigational drug or device study. 2. Subject with Systolic pulmonary arterial pressure (sPAP) \> 60mmHg as measured by Transthoracic Echocardiography (TTE) 3. Subject requiring another cardiac procedure in the framework of the index procedure; subject requiring a percutaneous procedure within 30 days before or after the procedure or a cardiac surgical procedure within 3 months before or after the procedure 4. Moderate or Severe tricuspid valve stenosis (defined as a mean gradient ≥5 mmHg at normal heart rate) 5. Aortic, mitral and/or pulmonic valve stenosis and/or regurgitation more than or equal to moderate 6. Mitral valve stenosis and/or regurgitation more than moderate 7. Intra-cardiac thrombus, mass or vegetation requiring active treatment. 8. Implanted inferior vena cava (IVC) filter. 9. Prior tricuspid repair or tricuspid replacement 10. Known allergy to contrast media, silicone, PET, Co-Cr, stainless steel or nitinol that cannot be adequately pre-medicated 11. History of cardiac transplantation 12. Contraindication to Transthoracic/Transoesophageal Echocardiography (TTE/TOE). 13. Endocarditis or severe infection within 12 months of scheduled implant procedure 14. Myocardial Infarction (MI) or known unstable angina within the 30 days prior to the index procedure 15. Cerebro Vascular Accident within the previous 6 months 16. Hemodynamic instability or on IV inotropes 17. Contraindication to anticoagulant therapy and antiplatelet therapy 18. Bleeding disorders or hypercoagulable condition (at risk of blood clots) 19. Active peptic ulcer or active GI bleeding within 3 months of scheduled implant procedure 20. Severe renal impairment or on dialysis 21. Life expectancy less than 12 months. 22. Acute anemia 23. Chronic Oral Steroid Use ≥ 6 months 24. Pregnant or lactating female of childbearing potential with a positive pregnancy test 24 hours before any study-related radiation exposure 25. Pulmonary embolism within the last 6 months 26. Tricuspid Valve Tethering distance \> 10 mm 27. Presence of trans-tricuspid pacemaker or defibrillator leads which are determined as immobile or interfering with the procedure, as evaluated by echocardiography. 28. Contra-indicated for blood transfusion or refuses transfusion 29. Patient undergoing emergency treatment 30. Patient without appropriate venous access

Design outcomes

Primary

MeasureTime frame
All-cause mortality of the Per Protocol cohort at 30 days post procedure.30 days post procedure

Secondary

MeasureTime frame
Echocardiographic changes compared to Baseline by means of echocardiographic semi-quantitative and quantitative measures30 days, three (3), six (6), twelve (12) and twenty-four (24) months post procedure
Functional changes as compared to Baseline for New York Heart Association (NYHA) classification30 days, three (3), six (6), twelve (12) and twenty-four (24) months post procedure
Number of individual adverse events related to the system or procedure.30 days, three (3), six (6), twelve (12) and twenty-four (24) months post procedure
Exercise tolerance (Six Minute Walk Test)30 days, three (3), six (6), twelve (12) and twenty-four (24) months post procedure
Quality of Life evaluation (Kansas City Cardiomyopathy Questionnaire).30 days, three (3), six (6), twelve (12) and twenty-four (24) months post procedure
Rate of Heart Failure event post-procedure defined as a heart failure hospitalization or a heart failure hospitalization equivalent30 days, three (3), six (6), twelve (12) and twenty-four (24) months post procedure

Countries

Australia, Belgium, Denmark, France, Germany, Netherlands, United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026