Skip to content

NVT ALLEGRA TAVI System TF in Failing Surgical Aortic Bioprosthesis

Investigation of the Safety and Performance of the NVT ALLEGRA TAVI System TF in Patients With Failed Surgical Aortic Bioprosthesis and Elevated Surgical Risk

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03287856
Acronym
VIVALL
Enrollment
30
Registered
2017-09-19
Start date
2017-08-11
Completion date
2019-10-27
Last updated
2020-01-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Transcatheter Aortic Valve Implantation

Keywords

Valve-in-valve, TAVI

Brief summary

The study investigates the technical feasibility of the replacement of failed surgical bioprosthetic aortic valves by the ALLEGRA Transcatheter Heart Valve (THV) and describes the safety and performance profile

Interventions

Implantation of the ALLEGRA Transcatheter Heart Valve in failing surgical bioprosthesis

Sponsors

NVT GmbH
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* ≥18 years * Symptomatic degeneration of aortic bioprosthesis showing echocardiographically mean aortic gradient \>40mmHg or peak jet velocity \>4.0m/s and AVA\<1.0cm2 OR symptomatic patients with severe bioprosthetic valve insufficiency. * High risk for redo surgery defined by STS ≥10% / EuroScore II ≥7% OR as assessed by the heart team * Has signed the Patient Informed Consent Form * Willing and able to comply with requirements of the study, including all follow-up visits * Female patients of childbearing potential have a negative pregnancy test ≤7 days before the procedure and are willing to use a reliable method of birth control for the duration of study participation

Exclusion criteria

* Low position of the coronary ostia, especially in combination with shallow sinuses * Echocardiographic evidence of intracardiac mass, thrombus or vegetation * Significant aortic disease such as severe obstructive calcification or marked tortuosity or kinking which will preclude a safe advancement of the ALLEGRA TAVI System TF * Iliofemoral vessel conditions such as severe obstructive calcification, severe tortuosity or kinking that would preclude safe placement of an 18 Fr introducer sheath or make endovascular access to the aortic valve impossible * Severe mitral insufficiency * Internal diameter of the bioprosthesis is ≤16 mm or \>28 mm * Patient prosthesis mismatch (EOAi ≤0.65 cm2/m2) as the underlying cause of the poor valve function and need for re-intervention * Non-valvular stenosis as the underlying cause of the poor valve function and need for re-intervention * Failing pre-existing prosthetic heart valve or prosthetic ring in any other position than aortic * Partially detached leaflets that in the aortic position may obstruct a coronary ostium. * Existence of aortic conduit, aortic arch replacement, stentless bioprosthesis and autologous valve replacement * Paravalvular leak of the failing surgical bioprosthesis (between failing surgical bioprosthesis and native annulus) * LVEF \<20% * Evidence of active endocarditis or other acute infections * End stage renal disease requiring chronic dialysis or creatinine clearance \<20 ml/min or serum creatinine \>3.0 mg/dl (264 µmol/l) * Known hypersensitivity to contrast media, which cannot be adequately pre-medicated or contraindication to anticoagulant or anti-platelet medication or to Nitinol alloy or to bovine tissue * Evidence of an acute myocardial infarction within the past 30 days * Cerebral vascular accident (TIA, Stroke) within past 6 months (≤180 days) * Evidence of active peptic ulcer or upper gastrointestinal bleeding within past 90 days * Untreated clinically significant coronary artery disease requiring revascularization * Hemodynamic instability (e.g. cardiogenic shock) requiring inotropic support or mechanical heart assistance (e.g. VAD, IABP) * Uncontrolled (therapy resistant) atrial fibrillation * Need for emergency surgery for any reason * Life expectancy ≤ 12 months due to other medical illness * Currently participating in another investigational drug or device study

Design outcomes

Primary

MeasureTime frameDescription
Mean pressure gradientimmediately after index-procedure
30-days survival30 daysProportion of participants with overall survival at 30 days

Secondary

MeasureTime frameDescription
Cardiovascular mortality30 days
Hemodynamic parametersup to12 monthspressure gradient, effective orifice area, velocity
New Pacemaker implantationup to 12 monthsProportion of patients with pacemaker implantations after index-procedure
Early safety30 daysall-cause mortality, all stroke (disabling and non-disabling), life-threatening bleeding, acute kidney injury stage 2 or 3 (including renal replacement therapy), coronary artery obstruction requiring Intervention, major vascular complication, valve-related dysfunction requiring repeat procedure
Time related valve safetyup to 12 monthsstructural valve deterioration as defined by * requiring repeat procedure (transcatheter or surgical heart valve replacement) * valve-related dysfunction defined by * mean aortic valve gradient ≥20 mmHg AND * no moderate or severe prosthetic valve regurgitation
Technical success of implantationimmediately after index-proceduredefined as absence of procedural mortality AND correct positioning of a single prosthetic heart valve into the proper anatomical location AND no severe (\<0.65 cm2/m2) prosthesis - patient mismatch AND mean aortic valve gradient \<20 mmHg AND no moderate or severe prosthetic valve regurgitation
NYHA classificationup to 12 months

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026