Skip to content

Apnea Tests as the Methods of Brain Death Diagnosis.

Alternative Apnea Test as the Method of Brain Death Diagnosis .

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03281993
Acronym
DiagBD
Enrollment
76
Registered
2017-09-13
Start date
2015-06-25
Completion date
2017-06-25
Last updated
2017-09-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Apnea, Brain Death, Pupillary Anomaly

Keywords

apnea test, brain death, pupillometry

Brief summary

Apnea test (AT) is the most important clinical test performed usually at the end of brain death (BD) diagnosis procedure. Traditional insufflation apnea test (I-AT) cannot be completed in patients with extremely compromised lung function due to rapid blood desaturation and circulatory disturbances. Therefore the investigators decided to verify alternative AT options such as continuous positive airway pressure apnea test (CPAP-AT) in patients with good and poor baseline oxygenation, before implementing them in currently reviewed Polish BD criteria.

Detailed description

Apnea test (AT) is one of the most important examination during the diagnosis of brain death. It is usually performed at the end of each series of clinical examinations during diagnostic process. The most popular standard insufflation apnea test (I-AT) may be potentially harmful. It may cause some serious complications including pneumothorax, severe hypoxemia, hemodynamic instability and even cardiac arrest. Therefore, the investigators decided to analyze apnea test in CPAP option (CPAP-AT) as a new tool. For safety of the study the investigators analyzed a method after BD diagnosis. Methods: I-AT and hypoventilation with 100 % oxygen (if needed) were performed according to Polish guidelines. Two hours after BD diagnosis was performed extra apnea test in CPAP option (CPAP-AT). Before CPAP-AT the patients were ventilated 100% oxygen. After then the ventilator settings were changed to CPAP mode with PEEP 10 cm H2O, PS 0 cm H2O, FiO2 1,0, flow 6L/min. Emergency apnea ventilation was turned off. At the beginning of CPAP mode and 10 minutes after, blood samples for arterial blood gases (ABG) were collected. If were observed rapid desaturation defined as a decline in O2 saturation below 85%, CPAP-AT was aborted and study was finished. During routine diagnosis of brain death, pupillary dilation after a neck flexion was observed in one case. Therefore, the investigators decided to use a pupillometer during brain death examination to find out how pupils react after a neck flexion and how often it happens. Pupil measurements were taken immediately after the diagnosis of brain death. The measurements of pupil diameter were taken twice: A - before neck flexion; B - after neck flexion. We used pupillometer: AlgiScan (Equip Medkey BV).

Interventions

OTHERCPAP AT

If the investigators observe rapid desaturation defined as a decline in O2 saturation below 85%; the CPAP apnea test (CPAP-AT) test was aborted.

Sponsors

Pomeranian Medical University Szczecin
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* brain death diagnosis

Exclusion criteria

* no

Design outcomes

Primary

MeasureTime frameDescription
Change from baseline arterial blood gases (ABG) during CPAP-AT10 minutesAfter 2 hours from I-AT was performed the alternative AT by CPAP ventilation mode. Before CPAP-AT the patients were ventilated 100% oxygen. After then the ventilator parameters were modified to: 0 H2O of pressure support (PS), 10 cm H2O of PEEP, 6l/min of O2 flow and 0.2 l/min of sensitivity. Before the test and 10 minutes after then was taken blood probe to ABG and type of ventilation change to pretest settings. The test is considered valid if there is no respiratory activity despite the rise of PaCO2 above 60mmHg and over 20mmHg above the baseline. If the investigators observe rapid desaturation defined as a decline in O2 saturation below 85%, CPAP-AT was aborterd.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026