Skip to content

The efficacy of the Integrated Water Jet Channel Colonoscopy in Water Exchange Method

Division of Gastroenterology, Department of Internal Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chiayi, Taiwan

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03279705
Enrollment
120
Registered
2017-09-12
Start date
2017-05-01
Completion date
2019-10-01
Last updated
2019-10-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Colon Disease, Colonoscopy

Keywords

water exchange, water jet channel colonoscopy, colonoscopy, cecal insertion time, adenoma detection rate

Brief summary

This prospective randomized controlled trial compared integrated water jet channel colonoscopy with traditional accessory channel colonoscopy in cecal insertion time among patients undergoing WE method colonoscopy.

Detailed description

When the WE method colonoscopy were done with the accessory channel for both infusing and suctioning of water. The water had to be suctioned or infused alternatively and increaed the insertion time. With the new designed endoscopy that integrated a separate water jet channel for infusing water, infusing and suctioning of water can be done at the same time. Besides, water jet pumping system could provide a powerful jet to help us open the collapse lumen and keep an appropriate distance between the mucosa and the lens, thus preventing loss of visualization. It will help the colonoscopist to find the way during insertion.

Interventions

DEVICEWater jet channel

The separate water jet channel was used for infusing water.

DEVICEAccessory channel

The accessory channel was used for infusing and/or suctioning water

Sponsors

Chih-wei Tseng
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Masking description

These codes were contained in pre-arranged opaque envelopes, which were opened immediately before insertion of the colonoscope.

Intervention model description

A total of 120 patients were allocated into one of two groups by computerized randomization. In group A (Two-channel group), clear water was infused through the water jet channel and dirty water was sucked form the accessy channel. In group B (One-channel group), water exchange was done by using the accessory channel for both infusing and suctioning of water.

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Underwent fully sedative colonoscopy with WE method in the outpatient department

Exclusion criteria

* Age \< 18 years old or \> 80 years old * Without standard colon preparation * Allergy to meperidine or propofol * With a history of partial colectomy * Refusal to provide written informed consent.

Design outcomes

Primary

MeasureTime frameDescription
cecal insertion time2 hoursCecal insertion time was defined as the time from insertion into the rectum to the time when the colonoscope tip passed to a point proximal to the ileocecal valve so that the base of cecum was visible.

Countries

Taiwan

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 18, 2026