Skip to content

Evaluation of Cerebral Elastography by Magnetic Resonance: Comparison of Healthy Subjects and Patients With Glial Tumor

The Relevance of Cerebral MRI Elastography in the Mechanical Characterization of Glial Tumors

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03274037
Acronym
g-BrainMRE
Enrollment
48
Registered
2017-09-06
Start date
2017-07-07
Completion date
2020-07-07
Last updated
2017-09-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Elasticity Imaging Techniques

Brief summary

MRI elastography detects the movement of tissues in the human body and monitors their response to mechanical stress in order to reveal their mechanical properties, like palpation. These depend on the structure of the tissues, their biological conditions and possible conditions. This non-invasive technique allows exploration of deep organs such as the brain that the doctor's hand can not reach. MRI elastography may prove to be an essential tool for study, diagnosis, staging and therapeutic monitoring of brain diseases. Neurodegenerative diseases (Alzheimer's, Parkinson's, Creutzfeldt-Jakobes) and cancers largely modify the mechanical properties of the affected tissues. For a first evaluation of the technique, we are interested in glial tumors representing half of the intracranial tumors in adults (incidence: 5 cases per 100 000 inhabitants), the second cancer in children and the third cause of death in l Young adult.

Detailed description

Initiated in 1996, magnetic resonance elastography detects the movement of tissues in the human body and monitors their response to mechanical stress in order to reveal their mechanical properties. These depend on the structure of the tissues, their biological conditions and the possible affections affecting them,. This technique, with recognized safety, allows us to replace the doctor's usual palpation of peripheral organs, such as the liver, or the breast, and to consider the exploration of deeper organs such as the heart or the brain ,. At the Bicêtre Inter-Establishment Center, under the direction of Ralph Sinkus of the Beaujon Hospital, the elastography of breast7 (for the exploration of tumors) and of the heart9 is already being studied . At the Hôpital de Beaujon, elastography was developed to study tumors, fibrosis and cirrhosis of the liver5. Through a vibrating bar, Mayo Clinic11, in the United States, then, in an oscillating cradle, Charity12, Germany, induced waves in the human brain and early measurements of the brain's elastography showed a Significant difference in the modulus of elasticity and viscosity of the white matter and the gray matter. The dependence of these modules on age and gender was discussed. The elasticity measured by MRI of tumors of 38 to 75 mm in diameter could also be correlated with the tissue consistency of the samples obtained during a surgical reduction. Finally, in a patient with a temporal glioma, the mean modulus of elasticity in the tumor region was measured by elastography close to 30% greater than in the corresponding region of the healthy hemisphere. But the difficulty of introducing a mechanical wave into the brain through the cranial chamber and the surrounding cerebro-spinal fluid limits the scope of the advanced results, which are essentially qualitative at the moment. The median amplitude of the displacements measured in the brain during these studies is only 7.33 μm at 40 Hz and drops to 2.70 μm at 120 Hz while it is more than 21 μm in the Liver and breast at 75 and 90 Hz respectively4. Recently, the IR4M has developed an original excitation device that allows to circumvent this limit. Displacements of cerebral tissues of several tens of micrometers have been reported by MRI and the inversion of the problem leading to the viscoelastic modules could be carried out on the whole of the human brain

Interventions

DIAGNOSTIC_TESTDevice for mechanical excitation by pressure waves

The IRM elastography technique, proven and patented in 2010 by the IR4M (Orsay, France), consists in characterizing by IRM induced waves in the human body in order to determine the mechanical properties Of the target organ. The mechanical waves will be induced by pressure waves guided at the mouth of the subject elongated in the MRI and consisting of a function generator at a frequency between 5 Hz and 500 Hz, linear amplifier , An electromechanical transducer, a waveguide whose length is adapted to the chosen excitation frequency, an antibacterial filter and a disposable mouthpiece The MRI imager Achieva 1.5 T MRI (Philips Healthcare, Best, the Netherlands) and the SIGNA Architect GEM 3.0T (GE medical systems, LLC, USA) system will be used to measure brain tissue displacement fields.

Sponsors

Assistance Publique - Hôpitaux de Paris
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

for healthy subjects will be: * Age between 18 and 65 years * Ability to hold in an MRI device without moving * No known and diagnosed neurological pathologies such as stroke, cerebral surgery, central nervous system tumor, inflammatory disease (such as multiple sclerosis), neurodegenerative disease (such as Alzheimer's, Parkinson's or Creutzfeldt-Jakobes's ), depression * Informed consent Inclusion criteria for patients will be: * Age between 18 and 65 years * Ability to hold in an MRI device without moving * Glial tumor greater than 3 mm diagnosed by standard MRI * Informed and informed consent

Exclusion criteria

for both patients and healthy subjects will be: * Inability to perform an MRI examination : claustrophobia, presence of ferromagnetic metallic foreign bodies, wearing a pace-maker, metallic cardiac prosthetic valve, cochlear implants, vascular clips, insulin pump, pregnancy, breastfeeding.. * Non-affiliation to a social security scheme (beneficiary or beneficiary) * Intercurrent disorder likely to disrupt test results * Patient under anticoagulant:

Design outcomes

Primary

MeasureTime frameDescription
normal values of cerebral MRI elastography in healthy volunteers1 monthMechanical excitation by pressure waves

Secondary

MeasureTime frameDescription
Values of shear modulus of elasticity in the brain region explored1 monthMechanical excitation by pressure waves
Values of shear viscosity modulus according to the explored region of the brain1 monthMechanical excitation by pressure waves

Countries

France

Contacts

Primary ContactDenis MD DUCREUX, PhD
denis.ducreux@bct.aphp.fr01 45 21 33 88
Backup ContactXavier MD MAITRE, PhD
xavier.maitre@u-psud.fr01 69 15 41 34

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026