Effect of Mobilisations on Lumbar and Hamstring

Investigating the Effect of L4 and L5 Lumbar Posterior -Anterior Mobilisations on Measures of Lumbar and Hamstring Range of Motion, and Electromyography Activity of the Erector Spinae and Hamstring

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03273400
Enrollment
18
Registered
2017-09-06
Start date
2017-09-22
Completion date
2018-03-01
Last updated
2018-04-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hamstring Injury

Keywords

Lumbar, Hamstring, Mobilisation

Brief summary

To compare the immediate and short-term effects of L4 and L5 Unilateral Posterior Anterior (UPA) Mobilisations on the lumbar and hamstring range of motion and EMG activity of the Erector Spinae and Hamstring muscles. Using a pre-test post-test crossover design subjects lumbar flexion and active knee extension with be recorded prior to and following unilateral zygapophyseal joint mobilisations. Measures will be taken immediately after and then 5, 10, 15, 20, 30 and 60 minutes intervals post intervention. Mobilisation force will be measured via force plates to ensure consistent mobilisation pressure. Following data collection statistical analysis will be undertaken to analyse any potential benefit of lumbar mobilisations to influence the EMG activity of the Erector Spinae and Hamstrings. Functional assessment of lumbar range of motion and hamstring range of motion to be conducted and analyse any effect on movement

Detailed description

25-30 participants will be tested in the Olympia Building Biomechanics Laboratory at Teesside University. Due to the nature of the cross-over design participants will attend the laboratory twice, one week apart. Baseline measurements of Lumbar flexion and hamstring range of motions will be taken. During lumbar flexion participants will be asked to stand with their arms at their side (anatomical position) and feet 8cm part. The tester will demonstrate the flexion motion then request the subject bends forwards are far as is possible, maintaining knee extension. A previous reliability study (Page 2012) has indicated four lumbar flexion movements repetitions were required to prevent the effects of passive stiffness improving the range. On the fourth trial the measurement via the modified schober test. This requires skin markers to be placed 10cm above and 5cm below the lumbar-sacral junction and the change distance calculated at end range. This will be conducted by the lead author, Paul Chesterton, a physiotherapist with appropriate insurance and qualifications. Hamstring extensibility will be measured via the active knee extension test. Test leg will be determined by dominant/kicking leg. Subjects will be secured into anterior pelvic tilt via a belt and asked to extend the knee to maximal length. A purpose made wooden wedge will provide a right angle surface to ensure the hip is held at 90 degrees. The digital inclinometer will record the change in degrees of active knee extension post-test. The knee will be extended to end range, determined by the subject, with the hip, knee and ankle maintained in neutral. The non-dominant leg will be secured to the bed via a belt. To record the surface electromyography (SEMG) activity in the muscles of the participants in this study the Zerowire Cometa system will be used. This system will record the muscle activity wirelessly. Every electrode unit is equipped with a small unit for signal processing and transmission to the data receiver. The electrodes are single use disposable, self-adhesive silver chloride dual snap on electrodes pre-set at a distance of 20mm. All participants will have the skin prepared prior to the noraxon electrode being placed on their skin. Skin preparation will consist of shaving the area to remove any hair then wiping the area with alcohol wipe then the placing noraxon dual electrode in appropriate position in relation to recommendations by Seniam (2003). The electrodes are placed in line to the pennant of the muscle. Electrodes will be attached according to European recommendation (seniam) at the Paraspinal muscles, and the Biceps Femoris of the dominant leg. A baseline sEMG will then be taken whilst the participant is at rest for 60seconds. The electrode placement and sEMG recording will be taken by a qualified laboratory technician employed by Teesside University. The intervention will consist of unilateral lumbar mobilisations at the L4 and L5 level in a Posterior Anterior direction. The plinth will rest on force plates to allow the authors to analyse the force placed through the vertebrae. Grade three mobilisations will be applied for a one minute period three times at both L4 and L5 level. Each level will be determined by a passive physiological intervertebral movement. Participants will receive the mobilisations at L5 first for one minute followed by L4. This is an appropriate dose for mobilisation application (Maitland, 2013). This process will be carried out three times. Following either the control or intervention all measure lumbar flexion, hamstring extensibility and sEMG activity will be recorded immediately, 5, 10, 15, 20, 30, 60 minutes post application as a single test. Data analysis will occur using the zerowire cometa system version 1.6. The raw rate will be smoothed and rectified using a Butterworth algorithm with a high pass filter with a cut of frequency of 20Hz at order 5 with the data will be rectified using route mean square (RMS) set at a window of 20ms.

Interventions

Please see arm (intervention) description

Sponsors

Teesside University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Intervention model description

The study will be a cross-over design. A pre-test post-test design will be used to evaluate the sEMG activity of the Erector Spinae muscle group and the Hamstring muscle (Biceps Femoris). Lumbar flexion range of motion and hamstring length will be tested prior too mobilisations and post intervention immediate and at intervals of 5, 10, 15, 20, 30, 60 minutes. Participants will be receive non-intervention one week and mobilisations the following week.

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* Age between 18-65. Participants willing to provide inform consent. Participants who successfully complete the medical questionnaire. No current lower back or lower limb pathology.

Exclusion criteria

* Current symptomatic low back pain or lower limb pathology. Participants with altered neurodynamic symptoms. Previous lumbar surgery. Under supervision of another health practionare Pregnant participants Contraindications or precautions to spinal mobilisation * malignancy, inflammatory or infectious processes involving the spine or peripheral joints, * osteoporosis, * spinal disorders including spondylolisthesis, ankylosing spondylitis, spinal fusion

Design outcomes

Primary

MeasureTime frameDescription
Lumbar Range of Motion5, 10, 15, 20, 30, 60 minutes post application as a single test.During lumbar flexion participants will be asked to stand with their arms at their side (anatomical position) and feet 8cm part. The tester will demonstrate the flexion motion then request the subject bends forwards are far as is possible, maintaining knee extension. A previous reliability study (Page 2012) has indicated four lumbar flexion movements repetitions were required to prevent the effects of passive stiffness improving the range. On the fourth trial the measurement via the modified schober test. This requires skin markers to be placed 10cm above and 5cm below the lumbar-sacral junction and the change distance calculated at end range.
Hamstring Range of Motion5, 10, 15, 20, 30, 60 minutes post application as a single test.Hamstring extensibility will be measured via the active knee extension test. Test leg will be determined by dominant/kicking leg. Subjects will be secured into anterior pelvic tilt via a belt and asked to extend the knee to maximal length. A purpose made wooden wedge will provide a right angle surface to ensure the hip is held at 90 degrees. The digital inclinometer will record the change in degrees of active knee extension post-test. The knee will be extended to end range, determined by the subject, with the hip, knee and ankle maintained in neutral. The non-dominant leg will be secured to the bed via a belt.
Electromyography of Erector Spinae5, 10, 15, 20, 30, 60 minutes post application as a single test.Record electromyography (SEMG) activity in the muscles of the participants in this study the Zerowire Cometa system will be used. Every electrode unit is equipped with a small unit for signal processing and transmission to the data receiver. The electrodes are single use disposable, self-adhesive silver chloride dual snap on electrodes pre-set at a distance of 20mm. All participants will have the skin prepared prior to the noraxon electrode being placed on their skin. Electrodes will be attached according to European recommendation (seniam) at the Paraspinal muscles (L1 region). A baseline sEMG will then be taken whilst the participant is at rest for 60seconds. The electrode placement and sEMG recording will be taken by a qualified laboratory technician employed by Teesside University.
Electromyography of Biceps Femoris5, 10, 15, 20, 30, 60 minutes post application as a single test.Record electromyography (SEMG) activity in the muscles of the participants in this study the Zerowire Cometa system will be used. Every electrode unit is equipped with a small unit for signal processing and transmission to the data receiver. The electrodes are single use disposable, self-adhesive silver chloride dual snap on electrodes pre-set at a distance of 20mm. All participants will have the skin prepared prior to the noraxon electrode being placed on their skin. Electrodes will be attached according to European recommendation (seniam) to the Biceps Femoris of the dominate leg. A baseline sEMG will then be taken whilst the participant is at rest for 60seconds. The electrode placement and sEMG recording will be taken by a qualified laboratory technician employed by Teesside University.