Conditions

Atherosclerosis of Femoral Artery, Intermittent Claudication, Peripheral Arterial Disease

Keywords

Distal embolization, Percutaneous transluminal angioplasty, Integrated embolic protection

Brief summary

The ENTRAP Study is a prospective, multi-center, non-randomized, single-arm, study with follow-up to 30 days to determine the acute safety, acute device performance and clinical performance of the Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic Protection. The Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic Protection is indicated for peripheral vascular percutaneous transluminal angioplasty (PTA) and capture and removal of embolic material during angioplasty for the femoral, iliac, popliteal and profunda arteries.

Detailed description

The ENTRAP Study is a prospective, multi-center, non-randomized, single-arm, study with follow-up to 30 days to determine the acute safety, acute device performance and clinical performance of the Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic Protection. The Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic Protection is indicated for peripheral vascular percutaneous transluminal angioplasty (PTA) and capture and removal of embolic material during angioplasty for the femoral, iliac, popliteal and profunda arteries. The Vanguard System has been designed to revascularize iliac and femoro-popliteal PAD while protecting against embolization at the same time. It is the first system in which the embolic protection filter is coupled on the same catheter as the angioplasty balloon for use in the lower extremities. Up to 130 patients will be enrolled into this study and followed for 30 days after post-procedure. Adult patients with lifestyle-limiting claudication or rest pain (Rutherford categories 2 to 3) who meet all eligibility criteria will be approached for participation in the trial.

Interventions

Percutaneous transluminal angioplasty (PTA) of the lower extremities

Sponsors

Contego Medical, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Male and female patients ≥18 years old. 2. Subject has clinically significant symptomatic leg ischemia requiring treatment. 3. Subject has a Rutherford category of 2 - 3. 4. Target lesion in the superficial femoral artery (SFA), common femoral artery, p1 segment of popliteal artery, common iliac artery and external iliac artery (cross-over access only), and profunda femoris arteries. 5. Target lesion stenosis \>50% by investigator's visual estimate. 6. Vessel diameter between 4.0 mm and 8.0 mm at the site of the target lesion. 7. Total target lesion length ≤ 18 cm, and may include a chronic total occlusion ≤ 10 cm. 8. If target lesion is restenotic, the prior PTA must be \> 30 days prior to enrollment. 9. If the guide wire traverses the lesion subintimally, it must enter the true lumen distal to the lesion without the use of a reentry device. 10. Distal vessel diameter at the site of filter deployment of 4.0 mm to 8.0 mm with sufficient landing zone required for the successful deployment of the integrated embolic protection filter. 11. Patent popliteal and infrapopliteal arteries; I.e. single vessel runoff or better with at least one of three vessels patient (\<50% stenosis) to the ankle or foot. 12. The patient (or legally authorized representative) is willing to provide written informed consent and to comply with all study requirements.

Exclusion criteria

1. Subjects who have undergone prior vascular surgery of the target artery to treat atherosclerotic disease. 2. History of major amputation in the same limb as the target lesion. 3. Woman who is pregnant or nursing. 4. Subject has Rutherford category of 4- 6. 5. Target lesion(s) within native or synthetic vessel grafts. 6. Use of atherectomy as an adjunctive therapy during the index procedure in the target lesion or target vessel. 7. Any major (e.g. cardiac, peripheral, abdominal) intervention, including in the contralateral lim planned within 30 days post index procedure. 8. Presence of other hemodynamically significant outflow lesion in the target limb requiring intervention within 30 days of enrollment. 9. Subject has significant inflow disease which cannot be treated prior to target lesion treatment. 10. Presence of aneurysm in the target vessel. 11. Acute limb occlusion due to thrombotic occlusion of the target limb. 12. In-stent restenosis of target lesion. 13. Severe calcification that renders the target lesion lesion resistant to angioplasty. 14. Visible acute thrombus in the target lesion 15. Intolerance to antiplatelet, anticoagulant or thrombolytic therapy medications that would be administered during the trial. 16. Known hypersensitivity to contrast media that cannot be adequately premedicated. 17. Known hypersensitivity to nickel and/or titanium. 18. Acute Myocardial Infarction within 30 days prior to the index procedure. 19. Subject has a known coagulopathy or bleeding diathesis, or INR \<1.5. 20. Platelet count \<100,000 mm3/L or \>700,000 mm3/L 21. Concomitant renal failure with a serum creatinine \> 2.5 mg/dL or receiving dialysis. 22. Patient is currently participating in an interventional study, investigational drug or device study that has not completed the primary endpoint, that may potentially confound the results of this trial or that would limit the subject's compliance with the follow-up requirements.

Design outcomes

Primary

MeasureTime frameDescription
Procedural success24 hours or at discharge.Defined as \<50% residual stenosis without MAE (death, amputation or TVR)
Freedom from MAE, defined as death, amputation and target vessel revascularization (TVR)30 daysPrimary safety endpoint

Secondary

MeasureTime frameDescription
Technical SuccessIndex procedureTechnical success of the investigational device using questionnaire
Ankle-Brachial Index (ABI)Baseline, discharge and 30 daysChange in Ankle-Brachial Index from baseline, discharge and 30 days