Physiological Behavior of Respiratory Maneuvers

Physiological Behavior of Respiratory Maneuvers Through Electrical Impedance Tomography and Optoelectronic Plethymography

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03270826
Enrollment
10
Registered
2017-09-01
Start date
2017-04-07
Completion date
2018-03-23
Last updated
2018-05-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy Volunteers

Brief summary

Introduction: new methods of evaluation of respiratory function, such as electrical impedance tomography (EIT) and optoelectronic plethysmography (OEP), have been used to measure regional pulmonary ventilation and the variation of tricompartmental volumes of the thoracic cavity, respectively. Analysis of these instruments during maximal respiratory maneuvers with monitoring of esophageal pressure may probably provide additional information on the physiological behavior of the cardiorespiratory system during EIT and OEP maneuvers. Objectives: To describe the physiological behavior of maximal respiratory maneuvers through the electrical impedance tomography and optoelectronic plethysmography in healthy men. METHODS: This is a cross-sectional study involving 10 healthy male volunteers. The development of the method will take place in 3 stages. The first step corresponds to the characterization of the inspiratory and expiratory curves in the respiratory cycle generated by the impedance variation (ΔZ), the mobility of the chest wall and the pulmonary volume curve during maximal respiratory maneuvers. 2nd stage: verification of the correlation between the variables Step 3: Estimate the dislocated blood volume of the lung through previous analyzes.

Detailed description

The physiological repercussions resulting from the maximal respiratory maneuvers together with the synchronized analysis of the chest cavity mobility, pulmonary volume , pulmonary impedance and measurement of Oesophageal pressure is not known. Therefore, this study aims to describe the physiological behavior of maximal respiratory maneuvers through the synchronization between electrical impedance tomography and optoelectronic plethysmography in healthy men.

Interventions

None listed

Sponsors

Universidade Federal de Pernambuco
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
MALE
Age
18 Years to 35 Years
Healthy volunteers
Yes

Inclusion criteria

* Will be included in the study male volunteers, * BMI greater than or equal to 18.5 and less than 25 kg / m2, considered adequate or eutrophic (MS, 2011) * Chest circumference between 44 and 55 cm if fitted to the electrical impedance tomography (EIT) strap size P or M; * systolic blood pressure lower than 140 mmHg and greater than 100 mmHg * diastolic blood pressure greater than 60 mmHg and lower than 90 mmHg (VI Brazilian Guidelines for Hypertension, 2010) * without reports of cardiovascular or pulmonary diseases and symptoms Last month.

Exclusion criteria

* Volunteers who refuse to participate in the study will be excluded from the survey; * Presence of cardiac dysfunction assessed by echocardiography; * Altered pulmonary function by spirometry (PEREIRA et al, 2001) and manovacuometry according to predicted values for healthy individuals (PESSOA et al, 2014). * Presence of tissue injury in the thorax; * Dysautonomia that may indicate dysfunction of the autonomic nervous system (ANS), with following clinical manifestations: seizures; epilepsy; Anhydrosis and hyperhidrosis; Neurogenic bladder (CASTRO et al, 1992); (Stewart et al., 2004 and 2005) * individuals who donated blood or had significant blood loss within 30 days prior to the start of the study (Navarro et al, 1997).

Design outcomes

Primary

MeasureTime frameDescription
Displacement of blood volume of the lung09/03/2018Volume displacement per unit time measured by electrical impedance tomography through the impedance variation in Ohm (Ω).

Secondary

MeasureTime frameDescription
Variation of pulmonary electrical impedance09/03/2018Variation between the final and initial impedance measured by electrical impedance tomography through the impedance variation in Ohm (Ω).

Other

MeasureTime frameDescription
Lung volume09/03/2018Measurement of the amount of air that the lungs may contain at various points in the respiratory cycle.