Skip to content

Air-Q® SP Versus Williams Intubating Airway for Single-Operator FOI

Comparison of Use of a Shortened Air-Q® Self-Pressurizing Intubating Laryngeal Airway Versus the Williams Intubating Airway for Single-Operator Flexible Bronchoscopic Intubation.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03247803
Enrollment
60
Registered
2017-08-14
Start date
2018-06-11
Completion date
2019-03-08
Last updated
2019-03-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intubation; Difficult or Failed, Laryngeal Masks

Keywords

Air-Q® SP, Williams Airway Intubator (WA), Flexible Bronchoscopic intubation (FBI), Fiberoptic Intubation (FOI), Fiberoptic Intubating Airway(FIA), Laryngeal Mask Airway

Brief summary

The air-Q and air-Q SP are commercially-available supraglottic airways (SGAs) that can be used for primary airway maintenance or as a conduit for FOI, as can be the Williams, Ovassapian, and Berman Intubating Airways. The air-Q products have the same overall geometrical design, but differ in their cuff inflating mechanisms, where the air-Q uses a traditional pilot balloon valve, while the air-Q SP utilizes a self-inflating cuff that dynamically adjusts according to the relative resistances to airflow between the patient's lungs and the device's cuff. The purpose of this study is to compare the single-operator intubation success using the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation (FBI) and to compare the single-operator intubation success using the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation. Both devices are commercially-available and being used in the study in accordance with their labeled intended use. The investigator envisage that the endpoint of the study will be single operator intubation success rate.

Detailed description

Despite the introduction of videolaryngoscopes, flexible bronchoscopic intubation (FBI), also known as fiberoptic intubation (FOI), remains a critical method for achieving tracheal intubation in patients with difficult airways. Unfortunately, however, FOI often requires two-operators for success. One operator is required to manipulate the flexible bronchoscope through the patient's upper airway and into their trachea, while the second operator applies one or more maneuvers (e.g., jaw thrust, anterior jaw lift, or lingual retraction) with or without the use of a commercially-available fiberoptic intubating airway. Previous studies have demonstrated the effectiveness of the currently available FIAs, but also illustrate the frequent need for an assistant for successful FOI. In this study, an assistant performed a jaw lift and a chin lift in all subjects as well. The air-Q and air-Q SP are commercially-available supraglottic airways (SGAs) that can be used for primary airway maintenance or as a conduit for FOI, as can be the Williams, Ovassapian, and Berman Intubating Airways. The air-Q products have the same overall geometrical design, but differ in their cuff inflating mechanisms, where the air-Q uses a traditional pilot balloon valve, while the air-Q SP utilizes a self-inflating cuff that dynamically adjusts according to the relative resistances to airflow between the patient's lungs and the device's cuff. In prior trials comparing the air-Q and air-Q SP with the two other commercially-available SGAs, the air-Q and air-Q SP bowl design provided a partial or full view of the vocal cords in 80-92% of subjects without requiring any additional airway maneuvers applied by an assistant (e.g., jaw thrust, anterior jaw lift, or lingual retraction) (Galgon, 2011; Galgon, 2015). Presumably, in these situations, successful tracheal intubation using the air-Q or air-Q SP could have been achieved by a single operator versus requiring one or more assistants. However, this potential performance advantage has not yet been tested. Therefore, the purpose of this study is to compare use of the air-Q SP against the WA for FBI performed by a single operator. The air-Q SP, rather than the air-Q, is chosen for this study because its lack of a pilot balloon valve allows its stem to be easily shortened to ease device removal over the coaxially placed tracheal tube. The WA is chosen for this study because it has performed best in past trials and is the airway routinely used by the study principal investigator (PI) for FBI. Both devices are commercially-available and being used in the study in accordance with their labeled intended use.

Interventions

DEVICEair-Q® SP

air-Q SP placement for airway maintenance,

DEVICEWilliams Airway Intubator (WA)

WA is placed in subject's oropharynx. If the vocal cords are not in view at the end of the WA, the operator may ask an assistant to perform an airway maneuver (e.g., jaw thrust, anterior jaw lift, or lingual traction) to attempt to bring the vocal cords into view

Sponsors

University of Wisconsin, Madison
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Masking description

Each study subject will be blinded to the study device they receive; however, the anesthesia provider will not be blinded to the study device and will have access to all monitors deemed appropriate by the primary anesthesia team caring for the subject.

Intervention model description

Adult patients presenting for a surgical or interventional procedure requiring general anesthesia and tracheal intubation, who do not meet any of the study exclusion criteria, and who give their informed consent, will be randomly allocated to receive either an air-Q SP or Williams Intubating Airway as a conduit to aid flexible bronchoscopic intubation.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Adult patients (≥18 years); 2. The patient is scheduled for an elective surgery or procedure that will take place in the UWHC main operating room, outpatient surgical center, or ambulatory procedure center; and 3. The patient's primary anesthesia care team has planned for general anesthesia with orotracheal intubation for airway maintenance.

Exclusion criteria

1. The patient is \< 18 years of age; 2. The patient is non-English speaking; 3. The patient is known or believed to be pregnant; 4. The patient is a prisoner; 5. The patient has impaired decision-making capacity; 6. The patient is at increased risk for aspiration, including non-fasted or emergency surgery, and cases of uncontrolled gastroesophageal reflux disease, hiatal hernia, gastroparesis, esophageal dysmotility, prior esophagectomy, and/or emesis within twenty-four hours of the surgery or procedure; 7. The patient has limited mouth opening or oropharyngeal anatomy making successful placement of the study airway conduit unlikely; 8. The patient has airway exam features, a medical condition, or a past airway management history, which prompts the attending anesthesiologist to plan to maintain spontaneous ventilation during tracheal intubation; 9. The patient pre-operatively is requiring supplemental oxygen; 10. The patient has moderate to severe cardiac disease, as evidenced by a left ventricular ejection fraction of ≤ 50% on the most recent echocardiogram, severe aortic valve stenosis, atrial fibrillation with a resting pre-operative heart rate of ≥ 90 beats per minute, and/or known, multi-vessel coronary artery, managed conservatively with medical management or by intervention with multiple coronary artery stents or coronary bypass grafting; and 11. The patient has an allergy to glycopyrrolate.

Design outcomes

Primary

MeasureTime frameDescription
The primary endpoint is single-operator intubation success.15 minutesThe primary purpose of this study is to compare the single-operator intubation success using the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation.

Secondary

MeasureTime frameDescription
Time required for each intubation attempt15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Overall intubation time15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Number of attempts required for conduit placement15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Number of attempts for successful intubation15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Time required for conduit placement15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Successful intubation method15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Tracheal tube dislodgment rate during conduit removal15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Oxygen desaturation rate15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Post operative sore throat rate.4 hoursThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation
Number and types of assistive airway maneuvers (e.g., jaw thrust, lingual retraction, etc.) for successful intubation15 minutesThe secondary purposes of this study are to compare device performance characteristics and patient responses to use of the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026