Performance of MammoAlert™, Point of Care System, for the Screening of Breast Cancer in Women 18 Years of Age or Older

Multi-Centric Screening of Breast Cancer Patients to Determine Efficiency and to Assess Sensitivity & Accuracy of Pandora CDx MammoAlertTM in Screening of Breast Cancer.

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03243877
Enrollment
2458
Registered
2017-08-09
Start date
2017-06-17
Completion date
2018-08-31
Last updated
2018-04-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast Cancer

Keywords

Screening, Mammography

Brief summary

POC Medical Systems has developed a Point of Care system for the screening of breast cancer in the general population. Via a proprietary algorithm, the MammoAlert™ is expected to determine breast cancer's risk level for a subject by identifying the presence in plasma of known biomarkers. The present study aims to determine the Sensitivity and Specificity of the test in plasma samples of subjects of whom the status vis-à-vis breast cancer is known.

Detailed description

2400 subjects will be screened for breast cancer in seven enrolling sites across the country to ensure diverse ethnicity. Positive subjects should be confirmed breast cancer positive by Mammography and/or biopsy. Breast cancer positive samples will be compared to the control group of samples obtained from women attending clinics for non-cancerous related pathology. Both Positive and Negative Predictive Values will be evaluated to determine accuracy and sensitivity of the screening test. Subjects whose known cancer positive or negative status do not match the test report will be followed up as appropriate, on case by case basis to identify false positive and false negative results.

Interventions

OTHERMammoAlert Screening Test

Plasma obtained from blood samples will be analyzed with the MammoAlert Screening Test for the presence of known breast cancer bio-markers.

Sponsors

POC Medical Systems, Inc.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum

Inclusion criteria

1. Ability to give informed consent. Written informed consent by the patient/patient's legally acceptable representative (LAR) for donating blood sample 2. Documented absence of cancer (other than Breast Cancer) 3. Documented (Mammography and/or Biopsy) diagnosis of Breast Cancer (IDC/ILC/DCIS ), any stage 4. Blood sample taken before any treatment for Breast Cancer was administered to the subject.

Exclusion criteria

1. Other malignancy besides breast cancer in the 5 years prior to obtaining the sample. 2. Therapies for breast cancer that have been administered within 1 year of obtaining the sample 3. Any condition (including psychiatric), which in the Investigator's opinion, places the patient at undue risk by participating in the study.

Design outcomes

Primary

MeasureTime frameDescription
Screening performance (i.e., sensitivity and specificity)Screening performance will be calculated at 4-monthsScreening performance: comprises the sensitivity and specificity of MammoAlert™. It represents the performance of the diagnostic test and is therefore independent of the prevalence of the disease in the studied sample of patients.

Secondary

MeasureTime frameDescription
Predictive values & likelihood ratiosPredictive values & likelihood ratios will be calculated at 4-monthsPositive predictive value: the probability that a subject has the disease given that the test result is positive will be estimated by: TP/(TP+FP). Negative predictive value: the probability that a subject does not have the disease given that the result of the test is negative will be estimated by TN/(TN+FN). Likelihood ratio (LR): the likelihood that a given test result would be expected in a patient with the target disorder compared to the likelihood that that same result would be expected in a patient without the target disorder.

Other

MeasureTime frameDescription
Accuracy of testAccuracy of test will be calculated at 4-monthsThe probability that the test result reflects the true disease state will be estimated as the proportion of cases for which the test result is correct: (TP+TN)/(TP+FP+TN+FN).
ReproducibilityReproducibility will be calculated at 4-monthsThe ability of MammoAlert™ to reveal the same result when repeatedly performed on the same sample, assessed repeatedly by the same reader

Countries

India

Outcome results

None listed